{"id":"https://openalex.org/W2897894570","doi":"https://doi.org/10.1109/tsg.2018.2875727","title":"Energy Optimization of HVAC Systems in Commercial Buildings Considering Indoor Air Quality Management","display_name":"Energy Optimization of HVAC Systems in Commercial Buildings Considering Indoor Air Quality Management","publication_year":2018,"publication_date":"2018-10-12","ids":{"openalex":"https://openalex.org/W2897894570","doi":"https://doi.org/10.1109/tsg.2018.2875727","mag":"2897894570"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2018.2875727","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2018.2875727","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5026971814","display_name":"Liang Yu","orcid":"https://orcid.org/0000-0001-5015-0320"},"institutions":[{"id":"https://openalex.org/I41198531","display_name":"Nanjing University of Posts and Telecommunications","ror":"https://ror.org/043bpky34","country_code":"CN","type":"education","lineage":["https://openalex.org/I41198531"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Liang Yu","raw_affiliation_strings":["Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China","institution_ids":["https://openalex.org/I41198531"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100636141","display_name":"Di Xie","orcid":"https://orcid.org/0000-0001-6116-6993"},"institutions":[{"id":"https://openalex.org/I41198531","display_name":"Nanjing University of Posts and Telecommunications","ror":"https://ror.org/043bpky34","country_code":"CN","type":"education","lineage":["https://openalex.org/I41198531"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Di Xie","raw_affiliation_strings":["Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China","institution_ids":["https://openalex.org/I41198531"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010485510","display_name":"Chongxin Huang","orcid":"https://orcid.org/0000-0003-0498-8100"},"institutions":[{"id":"https://openalex.org/I41198531","display_name":"Nanjing University of Posts and Telecommunications","ror":"https://ror.org/043bpky34","country_code":"CN","type":"education","lineage":["https://openalex.org/I41198531"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chongxin Huang","raw_affiliation_strings":["Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China","institution_ids":["https://openalex.org/I41198531"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100678341","display_name":"Tao Jiang","orcid":"https://orcid.org/0000-0002-8482-1046"},"institutions":[{"id":"https://openalex.org/I47720641","display_name":"Huazhong University of Science and Technology","ror":"https://ror.org/00p991c53","country_code":"CN","type":"education","lineage":["https://openalex.org/I47720641"]},{"id":"https://openalex.org/I4210138186","display_name":"Wuhan National Laboratory for Optoelectronics","ror":"https://ror.org/03c9ncn37","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210138186"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tao Jiang","raw_affiliation_strings":["Wuhan National Laboratory for Optoelectronics, School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan, China"],"affiliations":[{"raw_affiliation_string":"Wuhan National Laboratory for Optoelectronics, School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan, China","institution_ids":["https://openalex.org/I4210138186","https://openalex.org/I47720641"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5090513264","display_name":"Yulong Zou","orcid":"https://orcid.org/0000-0002-8461-5306"},"institutions":[{"id":"https://openalex.org/I41198531","display_name":"Nanjing University of Posts and Telecommunications","ror":"https://ror.org/043bpky34","country_code":"CN","type":"education","lineage":["https://openalex.org/I41198531"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yulong Zou","raw_affiliation_strings":["Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China"],"affiliations":[{"raw_affiliation_string":"Key Laboratory of Broadband Wireless Communication and Sensor Network Technology of Ministry of Education, Nanjing University of Posts and Telecommunications, Nanjing, China","institution_ids":["https://openalex.org/I41198531"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":["https://openalex.org/A5026971814"],"corresponding_institution_ids":["https://openalex.org/I41198531"],"apc_list":null,"apc_paid":null,"fwci":3.3476,"has_fulltext":false,"cited_by_count":85,"citation_normalized_percentile":{"value":0.92978655,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":100},"biblio":{"volume":"10","issue":"5","first_page":"5103","last_page":"5113"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12238","display_name":"Green IT and Sustainability","score":0.9480000138282776,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.8737649917602539},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"Indoor air quality","score":0.7506848573684692},{"id":"https://openalex.org/keywords/schedule","display_name":"Schedule","score":0.5770601630210876},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5737754106521606},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.543635904788971},{"id":"https://openalex.org/keywords/building-management-system","display_name":"Building management system","score":0.4753524959087372},{"id":"https://openalex.org/keywords/lyapunov-optimization","display_name":"Lyapunov optimization","score":0.45782217383384705},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.4412784278392792},{"id":"https://openalex.org/keywords/thermal-comfort","display_name":"Thermal comfort","score":0.4167528450489044},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.34157824516296387},{"id":"https://openalex.org/keywords/environmental-science","display_name":"Environmental science","score":0.27048248052597046},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2246420979499817},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.11886057257652283},{"id":"https://openalex.org/keywords/environmental-engineering","display_name":"Environmental engineering","score":0.09435898065567017}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.8737649917602539},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.7506848573684692},{"id":"https://openalex.org/C68387754","wikidata":"https://www.wikidata.org/wiki/Q7271585","display_name":"Schedule","level":2,"score":0.5770601630210876},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5737754106521606},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.543635904788971},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.4753524959087372},{"id":"https://openalex.org/C101403955","wikidata":"https://www.wikidata.org/wiki/Q6707083","display_name":"Lyapunov optimization","level":5,"score":0.45782217383384705},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.4412784278392792},{"id":"https://openalex.org/C133913538","wikidata":"https://www.wikidata.org/wiki/Q774514","display_name":"Thermal comfort","level":2,"score":0.4167528450489044},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.34157824516296387},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.27048248052597046},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2246420979499817},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.11886057257652283},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.09435898065567017},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C37935115","wikidata":"https://www.wikidata.org/wiki/Q6707085","display_name":"Lyapunov redesign","level":4,"score":0.0},{"id":"https://openalex.org/C2777052490","wikidata":"https://www.wikidata.org/wiki/Q5072826","display_name":"Chaotic","level":2,"score":0.0},{"id":"https://openalex.org/C191544260","wikidata":"https://www.wikidata.org/wiki/Q1238630","display_name":"Lyapunov exponent","level":3,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2018.2875727","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2018.2875727","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6600000262260437,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G1092477833","display_name":null,"funder_award_id":"BK20171446","funder_id":"https://openalex.org/F4320322769","funder_display_name":"Natural Science Foundation of Jiangsu Province"},{"id":"https://openalex.org/G1129850685","display_name":null,"funder_award_id":"2016CFA009","funder_id":"https://openalex.org/F4320322186","funder_display_name":"Natural Science Foundation of Hubei Province"},{"id":"https://openalex.org/G1613623347","display_name":null,"funder_award_id":"61771258","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G2108010669","display_name":null,"funder_award_id":"51507085","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G2252439329","display_name":null,"funder_award_id":"BK20150040","funder_id":"https://openalex.org/F4320322769","funder_display_name":"Natural Science Foundation of Jiangsu Province"},{"id":"https://openalex.org/G2679422940","display_name":null,"funder_award_id":"BK20150869","funder_id":"https://openalex.org/F4320322769","funder_display_name":"Natural Science Foundation of Jiangsu Province"},{"id":"https://openalex.org/G4812041702","display_name":null,"funder_award_id":"61502252","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G4906116743","display_name":null,"funder_award_id":"91738201","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G5237909679","display_name":null,"funder_award_id":"61729101","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G7877612717","display_name":null,"funder_award_id":"61671253","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G8041531263","display_name":null,"funder_award_id":"61522109","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G86993181","display_name":null,"funder_award_id":"2015ZDTD012","funder_id":"https://openalex.org/F4320335787","funder_display_name":"Fundamental Research Funds for the Central Universities"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320322186","display_name":"Natural Science Foundation of Hubei Province","ror":null},{"id":"https://openalex.org/F4320322769","display_name":"Natural Science Foundation of Jiangsu Province","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320335787","display_name":"Fundamental Research Funds for the Central Universities","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":39,"referenced_works":["https://openalex.org/W1976981503","https://openalex.org/W1983563831","https://openalex.org/W1993668741","https://openalex.org/W1997016889","https://openalex.org/W2002316308","https://openalex.org/W2018386036","https://openalex.org/W2033202841","https://openalex.org/W2043767053","https://openalex.org/W2068375961","https://openalex.org/W2075023395","https://openalex.org/W2078940037","https://openalex.org/W2080637564","https://openalex.org/W2109318516","https://openalex.org/W2115087314","https://openalex.org/W2124038732","https://openalex.org/W2137152139","https://openalex.org/W2141022831","https://openalex.org/W2142398389","https://openalex.org/W2306906380","https://openalex.org/W2317595689","https://openalex.org/W2326098656","https://openalex.org/W2345246782","https://openalex.org/W2423579730","https://openalex.org/W2460934579","https://openalex.org/W2508114006","https://openalex.org/W2513935212","https://openalex.org/W2525707554","https://openalex.org/W2568808500","https://openalex.org/W2581278673","https://openalex.org/W2588174609","https://openalex.org/W2625632007","https://openalex.org/W2735604903","https://openalex.org/W2741940505","https://openalex.org/W2767423272","https://openalex.org/W2782992486","https://openalex.org/W2786514502","https://openalex.org/W2894375619","https://openalex.org/W2963211073","https://openalex.org/W4248237392"],"related_works":["https://openalex.org/W2357294886","https://openalex.org/W3038059713","https://openalex.org/W4281749375","https://openalex.org/W2079922090","https://openalex.org/W2017084161","https://openalex.org/W4388647520","https://openalex.org/W1525696263","https://openalex.org/W2182087970","https://openalex.org/W2538009942","https://openalex.org/W2104957212"],"abstract_inverted_index":{"To":[0,140],"intelligently":[1],"schedule":[2],"heating,":[3],"ventilation,":[4],"and":[5,19,31,56,87,109,120,128,172],"air":[6,21],"conditioning":[7],"(HVAC)":[8],"systems":[9,55],"for":[10],"reducing":[11],"energy":[12,50],"cost":[13,51,59,99,199],"of":[14,33,45,49,74,80,84,106,115,152,159,194,209],"commercial":[15,65],"buildings,":[16],"indoor":[17,20,107,170,178,185,195],"temperature":[18,82,108],"quality":[22],"(IAQ)":[23],"should":[24],"be":[25,36,201],"jointly":[26],"considered.":[27],"Otherwise,":[28],"the":[29,43,47,104,113,124,137,150,160,182,190,197,207,210],"health":[30],"productivity":[32],"occupants":[34,62],"may":[35],"affected.":[37],"In":[38],"this":[39,141],"paper,":[40],"we":[41,93,143],"investigate":[42],"problem":[44,101],"minimizing":[46],"sum":[48],"associated":[52],"with":[53],"HVAC":[54],"thermal":[57,89],"discomfort":[58],"related":[60,168],"to":[61,112,135,164,169],"in":[63],"multi-zone":[64],"buildings":[66],"considering":[67],"IAQ":[68],"management.":[69],"Firstly,":[70],"by":[71],"taking":[72],"uncertainties":[73],"electricity":[75],"price,":[76],"outdoor":[77],"temperature,":[78],"number":[79],"occupants,":[81],"preference":[83],"each":[85],"occupant,":[86],"external":[88],"disturbance":[90],"into":[91],"consideration,":[92],"formulate":[94],"a":[95,145],"time-averaged":[96],"expected":[97],"total":[98,198],"minimization":[100],"without":[102],"violating":[103],"constraints":[105],"IAQ.":[110],"Due":[111],"existence":[114],"uncertain":[116],"system":[117],"parameters,":[118],"temporally":[119],"spatially":[121],"coupled":[122],"constraints,":[123,130],"nonconvex":[125,129],"objective":[126],"function,":[127],"it":[131],"is":[132,163],"particularly":[133],"challenging":[134],"solve":[136],"formulated":[138],"problem.":[139],"end,":[142],"propose":[144],"real-time":[146],"algorithm":[147,162],"based":[148],"on":[149],"framework":[151],"Lyapunov":[153],"optimization":[154],"techniques.":[155],"The":[156],"key":[157],"idea":[158],"proposed":[161,211],"construct":[165],"virtual":[166],"queues":[167,175],"temperatures":[171,179],"stabilize":[173],"such":[174],"so":[176],"that":[177],"fluctuate":[180],"around":[181],"ideal":[183],"time-average":[184],"temperature.":[186],"By":[187],"dynamically":[188],"controlling":[189],"average":[191],"fluctuation":[192],"level":[193],"temperatures,":[196],"could":[200],"optimized.":[202],"Extensive":[203],"simulation":[204],"results":[205],"show":[206],"effectiveness":[208],"algorithm.":[212]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":15},{"year":2024,"cited_by_count":13},{"year":2023,"cited_by_count":11},{"year":2022,"cited_by_count":19},{"year":2021,"cited_by_count":11},{"year":2020,"cited_by_count":13},{"year":2019,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
