{"id":"https://openalex.org/W2891339011","doi":"https://doi.org/10.1109/tsg.2018.2868967","title":"A Fault Detection Method of Microgrids With Grid-Connected Inverter Interfaced Distributed Generators Based on the PQ Control Strategy","display_name":"A Fault Detection Method of Microgrids With Grid-Connected Inverter Interfaced Distributed Generators Based on the PQ Control Strategy","publication_year":2018,"publication_date":"2018-09-13","ids":{"openalex":"https://openalex.org/W2891339011","doi":"https://doi.org/10.1109/tsg.2018.2868967","mag":"2891339011"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2018.2868967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2018.2868967","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100635094","display_name":"Fan Zhang","orcid":"https://orcid.org/0000-0001-8424-1909"},"institutions":[{"id":"https://openalex.org/I116953780","display_name":"Tongji University","ror":"https://ror.org/03rc6as71","country_code":"CN","type":"education","lineage":["https://openalex.org/I116953780"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Fan Zhang","raw_affiliation_strings":["College of Electronics and Information Engineering, Tongji University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"College of Electronics and Information Engineering, Tongji University, Shanghai, China","institution_ids":["https://openalex.org/I116953780"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5018639963","display_name":"Longhua Mu","orcid":"https://orcid.org/0000-0002-7493-9630"},"institutions":[{"id":"https://openalex.org/I116953780","display_name":"Tongji University","ror":"https://ror.org/03rc6as71","country_code":"CN","type":"education","lineage":["https://openalex.org/I116953780"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Longhua Mu","raw_affiliation_strings":["College of Electronics and Information Engineering, Tongji University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"College of Electronics and Information Engineering, Tongji University, Shanghai, China","institution_ids":["https://openalex.org/I116953780"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5100635094"],"corresponding_institution_ids":["https://openalex.org/I116953780"],"apc_list":null,"apc_paid":null,"fwci":7.2957,"has_fulltext":false,"cited_by_count":120,"citation_normalized_percentile":{"value":0.97567243,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":99,"max":100},"biblio":{"volume":"10","issue":"5","first_page":"4816","last_page":"4826"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9904999732971191,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.915276825428009},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.7411559820175171},{"id":"https://openalex.org/keywords/low-voltage-ride-through","display_name":"Low voltage ride through","score":0.6061426401138306},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.5802798271179199},{"id":"https://openalex.org/keywords/inverter","display_name":"Inverter","score":0.5620689988136292},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.5526033639907837},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.5449780225753784},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5290046334266663},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.45095670223236084},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.42808935046195984},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.4275491237640381},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.42710036039352417},{"id":"https://openalex.org/keywords/ac-power","display_name":"AC power","score":0.419824481010437},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.41970810294151306},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.39190515875816345},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3842758536338806},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3425648808479309},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.13641121983528137},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.13610604405403137},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.08557441830635071},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.07404971122741699}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.915276825428009},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.7411559820175171},{"id":"https://openalex.org/C2780438294","wikidata":"https://www.wikidata.org/wiki/Q6693052","display_name":"Low voltage ride through","level":4,"score":0.6061426401138306},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5802798271179199},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.5620689988136292},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.5526033639907837},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.5449780225753784},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5290046334266663},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.45095670223236084},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.42808935046195984},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.4275491237640381},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.42710036039352417},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.419824481010437},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.41970810294151306},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39190515875816345},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3842758536338806},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3425648808479309},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.13641121983528137},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.13610604405403137},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.08557441830635071},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.07404971122741699},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2018.2868967","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2018.2868967","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4699999988079071,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W1985356703","https://openalex.org/W1994959046","https://openalex.org/W2003822479","https://openalex.org/W2010722346","https://openalex.org/W2012027212","https://openalex.org/W2029237874","https://openalex.org/W2034102307","https://openalex.org/W2034419495","https://openalex.org/W2039504478","https://openalex.org/W2039975803","https://openalex.org/W2042103507","https://openalex.org/W2047900829","https://openalex.org/W2051005341","https://openalex.org/W2058543607","https://openalex.org/W2063895100","https://openalex.org/W2071370587","https://openalex.org/W2080789495","https://openalex.org/W2112882275","https://openalex.org/W2140044058","https://openalex.org/W2144680725","https://openalex.org/W2158266110","https://openalex.org/W2160907941","https://openalex.org/W2169820194","https://openalex.org/W2329521860","https://openalex.org/W2343079212","https://openalex.org/W2495086869","https://openalex.org/W2560119810","https://openalex.org/W2746580097","https://openalex.org/W2747916555"],"related_works":["https://openalex.org/W4210780382","https://openalex.org/W2057975886","https://openalex.org/W2355150740","https://openalex.org/W1570369983","https://openalex.org/W2906602677","https://openalex.org/W2051053503","https://openalex.org/W195896717","https://openalex.org/W3112588909","https://openalex.org/W1993958856","https://openalex.org/W2757449142"],"abstract_inverted_index":{"The":[0,98],"fault":[1,56,65,81,99,106,117,126,151],"characteristics":[2,83],"of":[3,48,59,67,84,119,128,149],"an":[4,74],"inverter":[5],"interfaced":[6],"distributed":[7],"generator":[8],"(IIDG)":[9],"depend":[10],"on":[11,54,63,110],"its":[12],"control":[13,46],"strategy":[14,47],"and":[15,50,95,123,142],"whether":[16],"it":[17,39],"has":[18],"a":[19,28,32,60,68,85,104],"low":[20],"voltage":[21,122],"ride-through":[22],"(LVRT)":[23],"capability,":[24],"which":[25],"cannot":[26],"be":[27],"simple":[29],"equivalent":[30],"to":[31,42],"constant":[33],"power":[34],"or":[35],"current":[36],"source.":[37],"Thus,":[38],"is":[40,101,136],"necessary":[41],"consider":[43],"the":[44,55,64,80,111,115,120,124,129,132,139,143,147,150],"specific":[45,52],"IIDGs":[49],"perform":[51],"research":[53],"detection":[57,107,152],"method":[58,108],"microgrid.":[61],"Based":[62],"models":[66],"grid-connected":[69],"PQ":[70],"controlled":[71],"DG":[72],"with":[73],"LVRT":[75],"capacity,":[76],"this":[77],"paper":[78],"analyzed":[79],"component":[82,118],"microgrid":[86],"under":[87],"different":[88],"operating":[89],"conditions,":[90],"such":[91],"as":[92],"high-impedance":[93],"faults":[94],"low-impedance":[96],"faults.":[97],"point":[100],"located":[102],"using":[103],"new":[105],"based":[109],"phase":[112],"differences":[113],"between":[114],"positive-sequence":[116,125],"bus":[121],"components":[127],"currents":[130],"in":[131,138],"feeders.":[133],"Finally,":[134],"PSCAD/EMTDC":[135],"used":[137],"simulation":[140,144],"analysis,":[141],"results":[145],"verified":[146],"validity":[148],"method.":[153]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":21},{"year":2024,"cited_by_count":16},{"year":2023,"cited_by_count":18},{"year":2022,"cited_by_count":22},{"year":2021,"cited_by_count":16},{"year":2020,"cited_by_count":13},{"year":2019,"cited_by_count":10}],"updated_date":"2026-03-31T07:56:22.981413","created_date":"2025-10-10T00:00:00"}
