{"id":"https://openalex.org/W2782834297","doi":"https://doi.org/10.1109/tsg.2018.2794994","title":"Simultaneous Placement of Fault Indicator and Sectionalizing Switch in Distribution Networks","display_name":"Simultaneous Placement of Fault Indicator and Sectionalizing Switch in Distribution Networks","publication_year":2018,"publication_date":"2018-01-18","ids":{"openalex":"https://openalex.org/W2782834297","doi":"https://doi.org/10.1109/tsg.2018.2794994","mag":"2782834297"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2018.2794994","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2018.2794994","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048975224","display_name":"Mohammad Farajollahi","orcid":"https://orcid.org/0000-0003-2073-4979"},"institutions":[{"id":"https://openalex.org/I133529467","display_name":"Sharif University of Technology","ror":"https://ror.org/024c2fq17","country_code":"IR","type":"education","lineage":["https://openalex.org/I133529467"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Mohammad Farajollahi","raw_affiliation_strings":["Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran"],"affiliations":[{"raw_affiliation_string":"Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I133529467"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038158100","display_name":"Mahmud Fotuhi\u2010Firuzabad","orcid":"https://orcid.org/0000-0002-5507-9938"},"institutions":[{"id":"https://openalex.org/I133529467","display_name":"Sharif University of Technology","ror":"https://ror.org/024c2fq17","country_code":"IR","type":"education","lineage":["https://openalex.org/I133529467"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Mahmud Fotuhi-Firuzabad","raw_affiliation_strings":["Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran"],"affiliations":[{"raw_affiliation_string":"Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I133529467"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5019158317","display_name":"Amir Safdarian","orcid":"https://orcid.org/0000-0003-0555-8858"},"institutions":[{"id":"https://openalex.org/I133529467","display_name":"Sharif University of Technology","ror":"https://ror.org/024c2fq17","country_code":"IR","type":"education","lineage":["https://openalex.org/I133529467"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Amir Safdarian","raw_affiliation_strings":["Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran"],"affiliations":[{"raw_affiliation_string":"Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I133529467"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5048975224"],"corresponding_institution_ids":["https://openalex.org/I133529467"],"apc_list":null,"apc_paid":null,"fwci":12.3302,"has_fulltext":false,"cited_by_count":98,"citation_normalized_percentile":{"value":0.99165551,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":100},"biblio":{"volume":"10","issue":"2","first_page":"2278","last_page":"2287"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9976000189781189,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/automation","display_name":"Automation","score":0.7772701382637024},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.7028713226318359},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6955814361572266},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.6013082265853882},{"id":"https://openalex.org/keywords/integer-programming","display_name":"Integer programming","score":0.578838586807251},{"id":"https://openalex.org/keywords/service","display_name":"Service (business)","score":0.5535199046134949},{"id":"https://openalex.org/keywords/fault-management","display_name":"Fault management","score":0.5343818664550781},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5260517597198486},{"id":"https://openalex.org/keywords/fault-model","display_name":"Fault model","score":0.4866267144680023},{"id":"https://openalex.org/keywords/linear-programming","display_name":"Linear programming","score":0.4618681073188782},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.41942083835601807},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.41308265924453735},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.08294269442558289}],"concepts":[{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.7772701382637024},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7028713226318359},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6955814361572266},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6013082265853882},{"id":"https://openalex.org/C56086750","wikidata":"https://www.wikidata.org/wiki/Q6042592","display_name":"Integer programming","level":2,"score":0.578838586807251},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.5535199046134949},{"id":"https://openalex.org/C108074857","wikidata":"https://www.wikidata.org/wiki/Q3067360","display_name":"Fault management","level":3,"score":0.5343818664550781},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5260517597198486},{"id":"https://openalex.org/C167391956","wikidata":"https://www.wikidata.org/wiki/Q1401211","display_name":"Fault model","level":3,"score":0.4866267144680023},{"id":"https://openalex.org/C41045048","wikidata":"https://www.wikidata.org/wiki/Q202843","display_name":"Linear programming","level":2,"score":0.4618681073188782},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.41942083835601807},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.41308265924453735},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.08294269442558289},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.0},{"id":"https://openalex.org/C62611344","wikidata":"https://www.wikidata.org/wiki/Q1062658","display_name":"Node (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C136264566","wikidata":"https://www.wikidata.org/wiki/Q159810","display_name":"Economy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2018.2794994","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2018.2794994","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320322243","display_name":"Iran National Science Foundation","ror":"https://ror.org/03sr1ma14"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W1595138318","https://openalex.org/W1999300672","https://openalex.org/W2019125309","https://openalex.org/W2044102427","https://openalex.org/W2053598626","https://openalex.org/W2070966602","https://openalex.org/W2082154838","https://openalex.org/W2084616826","https://openalex.org/W2086309685","https://openalex.org/W2111175290","https://openalex.org/W2118268245","https://openalex.org/W2122006229","https://openalex.org/W2124947072","https://openalex.org/W2129373404","https://openalex.org/W2129641798","https://openalex.org/W2133311599","https://openalex.org/W2136427685","https://openalex.org/W2148280599","https://openalex.org/W2149820380","https://openalex.org/W2153208593","https://openalex.org/W2160216446","https://openalex.org/W2160954840","https://openalex.org/W2414824450","https://openalex.org/W2537373408","https://openalex.org/W2560318369","https://openalex.org/W2570940229","https://openalex.org/W2746604207","https://openalex.org/W2769811432","https://openalex.org/W2770443035","https://openalex.org/W4253705378","https://openalex.org/W6732078102","https://openalex.org/W6743314945"],"related_works":["https://openalex.org/W4285278887","https://openalex.org/W2365237642","https://openalex.org/W2995925505","https://openalex.org/W2773399470","https://openalex.org/W3116484972","https://openalex.org/W2941986668","https://openalex.org/W2135993994","https://openalex.org/W2372169186","https://openalex.org/W2560997738","https://openalex.org/W2160179184"],"abstract_inverted_index":{"Automation":[0],"systems":[1],"provide":[2],"substantial":[3],"improvement":[4],"in":[5,96,137],"service":[6,49,139],"reliability":[7,50,140],"through":[8,118],"speeding":[9],"up":[10],"fault":[11,61],"management":[12],"procedure.":[13],"However,":[14],"this":[15],"is":[16,76,94,116],"at":[17],"expense":[18],"of":[19,73,87,112,134],"high":[20],"investments":[21],"whose":[22],"justification":[23],"needs":[24],"thorough":[25],"cost/worth":[26],"analyses.":[27],"This":[28],"paper":[29],"introduces":[30],"a":[31,46,119,123],"mathematical":[32],"model":[33,44,93,115,136],"to":[34],"optimally":[35],"place":[36],"automation":[37,58],"system":[38,59,121,145],"devices":[39],"within":[40],"distribution":[41,125],"networks.":[42],"The":[43,91,110,127],"establishes":[45],"trade-off":[47],"between":[48],"improvements":[51],"and":[52,63,81,122],"the":[53,71,85,88,97,113,131,135],"relevant":[54],"costs.":[55,146],"Among":[56],"different":[57],"devices,":[60],"indicators":[62],"remote":[64],"controlled":[65],"switches":[66,75],"are":[67],"considered":[68],"here.":[69],"Also,":[70],"impact":[72],"manual":[74],"regarded":[77],"since":[78],"their":[79],"number":[80],"location":[82],"significantly":[83],"affect":[84],"solution":[86],"placement":[89],"problem.":[90],"proposed":[92,114],"developed":[95],"mixed":[98],"integer":[99],"programming":[100],"format":[101],"which":[102],"can":[103],"be":[104],"effectively":[105],"solved":[106],"via":[107],"available":[108],"solvers.":[109],"effectiveness":[111],"demonstrated":[117],"test":[120],"real-life":[124],"network.":[126],"obtained":[128],"results":[129],"indicate":[130],"great":[132],"performance":[133],"enhancing":[138],"as":[141,143],"well":[142],"reducing":[144]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":14},{"year":2023,"cited_by_count":13},{"year":2022,"cited_by_count":17},{"year":2021,"cited_by_count":18},{"year":2020,"cited_by_count":14},{"year":2019,"cited_by_count":10},{"year":2018,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
