{"id":"https://openalex.org/W2767570772","doi":"https://doi.org/10.1109/tsg.2017.2772327","title":"On Microgrid Evolution to Local Area Energy Network (E-LAN)","display_name":"On Microgrid Evolution to Local Area Energy Network (E-LAN)","publication_year":2017,"publication_date":"2017-11-10","ids":{"openalex":"https://openalex.org/W2767570772","doi":"https://doi.org/10.1109/tsg.2017.2772327","mag":"2767570772"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2017.2772327","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2772327","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5058391839","display_name":"Paolo Tenti","orcid":"https://orcid.org/0000-0002-8715-7777"},"institutions":[{"id":"https://openalex.org/I138689650","display_name":"University of Padua","ror":"https://ror.org/00240q980","country_code":"IT","type":"education","lineage":["https://openalex.org/I138689650"]}],"countries":["IT"],"is_corresponding":true,"raw_author_name":"Paolo Tenti","raw_affiliation_strings":["Department of Information Engineering, University of Padova, Padova, Italy"],"affiliations":[{"raw_affiliation_string":"Department of Information Engineering, University of Padova, Padova, Italy","institution_ids":["https://openalex.org/I138689650"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5060719629","display_name":"Tommaso Caldognetto","orcid":"https://orcid.org/0000-0002-0994-5305"},"institutions":[{"id":"https://openalex.org/I138689650","display_name":"University of Padua","ror":"https://ror.org/00240q980","country_code":"IT","type":"education","lineage":["https://openalex.org/I138689650"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Tommaso Caldognetto","raw_affiliation_strings":["Interdepartmental Centre Giorgio Levi Cases, University of Padova, Padova, Italy"],"affiliations":[{"raw_affiliation_string":"Interdepartmental Centre Giorgio Levi Cases, University of Padova, Padova, Italy","institution_ids":["https://openalex.org/I138689650"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5058391839"],"corresponding_institution_ids":["https://openalex.org/I138689650"],"apc_list":null,"apc_paid":null,"fwci":2.0336,"has_fulltext":false,"cited_by_count":23,"citation_normalized_percentile":{"value":0.87708319,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"10","issue":"2","first_page":"1567","last_page":"1576"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9951000213623047,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8082446455955505},{"id":"https://openalex.org/keywords/local-area-network","display_name":"Local area network","score":0.6271812915802002},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45704489946365356},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.44669976830482483},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.4024464786052704},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.3589058518409729},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.34713131189346313},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2928399443626404},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.2286587357521057}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8082446455955505},{"id":"https://openalex.org/C137471899","wikidata":"https://www.wikidata.org/wiki/Q11381","display_name":"Local area network","level":2,"score":0.6271812915802002},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45704489946365356},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.44669976830482483},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.4024464786052704},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.3589058518409729},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.34713131189346313},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2928399443626404},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.2286587357521057}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2017.2772327","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2772327","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:www.research.unipd.it:11577/3251247","is_oa":false,"landing_page_url":"http://ieeexplore.ieee.org/document/8103786/","pdf_url":null,"source":{"id":"https://openalex.org/S4377196283","display_name":"Research Padua  Archive (University of Padua)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I138689650","host_organization_name":"University of Padua","host_organization_lineage":["https://openalex.org/I138689650"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8600000143051147}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W1502540576","https://openalex.org/W1504052325","https://openalex.org/W1552714839","https://openalex.org/W1589032291","https://openalex.org/W1607148962","https://openalex.org/W1759197186","https://openalex.org/W1963185969","https://openalex.org/W1964013963","https://openalex.org/W1974059941","https://openalex.org/W1994959046","https://openalex.org/W2020615356","https://openalex.org/W2025143619","https://openalex.org/W2038128626","https://openalex.org/W2039353469","https://openalex.org/W2071370587","https://openalex.org/W2094934954","https://openalex.org/W2102354354","https://openalex.org/W2102777929","https://openalex.org/W2125750491","https://openalex.org/W2130077382","https://openalex.org/W2130820962","https://openalex.org/W2140501791","https://openalex.org/W2165892678","https://openalex.org/W2283997584","https://openalex.org/W2317145150","https://openalex.org/W2319808916","https://openalex.org/W2330031180","https://openalex.org/W2343000657","https://openalex.org/W2343661562","https://openalex.org/W2343706987","https://openalex.org/W2345246782","https://openalex.org/W2460952529","https://openalex.org/W2518965400","https://openalex.org/W2557139593","https://openalex.org/W2565898372","https://openalex.org/W2566288743","https://openalex.org/W2593249465","https://openalex.org/W3098344893","https://openalex.org/W3106327698","https://openalex.org/W6730104557","https://openalex.org/W6910679965"],"related_works":["https://openalex.org/W1574359403","https://openalex.org/W2057975886","https://openalex.org/W4308700935","https://openalex.org/W2355150740","https://openalex.org/W1570369983","https://openalex.org/W2906602677","https://openalex.org/W2051053503","https://openalex.org/W195896717","https://openalex.org/W3112588909","https://openalex.org/W1993958856"],"abstract_inverted_index":{"Owing":[0],"to":[1,21,40,46,118],"the":[2,53,67,74,131],"increasing":[3],"penetration":[4],"of":[5,33,42,52,56,66,73,104,121,130],"information":[6],"and":[7,10,37,49,80,94,101,124,126],"communication":[8],"technologies":[9],"power":[11,96,132],"electronics,":[12],"lowvoltage":[13],"microgrids":[14],"with":[15,31],"distributed":[16,57],"generation":[17],"may":[18],"progressively":[19],"evolve":[20],"local":[22],"area":[23],"energy":[24,29,58],"networks":[25,30],"(E-LANs),":[26],"that":[27],"is,":[28],"degrees":[32],"flexibility,":[34],"reliability,":[35],"robustness,":[36],"readiness":[38],"similar":[39],"LANs":[41],"digital":[43],"devices.":[44],"Thanks":[45],"grid":[47,99],"meshing":[48],"synergistic":[50],"exploitation":[51],"control":[54,65,113,129],"potential":[55],"resources,":[59],"E-LANs":[60],"can":[61],"provide":[62],"an":[63,111],"independent":[64,128],"currents":[68],"flowing":[69],"in":[70],"each":[71],"feeder":[72],"grid.":[75],"On":[76],"this":[77],"basis,":[78],"new":[79],"advanced":[81],"functionalities":[82],"become":[83],"possible,":[84],"like,":[85],"simultaneous":[86],"demand":[87],"response":[88],"at":[89],"multiple":[90],"utility":[91],"terminals,":[92],"active":[93,102],"reactive":[95],"steering":[97],"through":[98],"feeders,":[100],"clearing":[103],"lines":[105],"for":[106,114],"maintenance.":[107],"This":[108],"paper":[109],"presents":[110],"optimal":[112],"E-LANs,":[115],"which":[116],"applies":[117],"low-voltage":[119],"grids":[120],"any":[122],"structure":[123],"complexity":[125],"assures":[127],"fed":[133],"by":[134],"prosumers.":[135]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2024,"cited_by_count":4},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":2}],"updated_date":"2026-03-17T09:09:15.849793","created_date":"2025-10-10T00:00:00"}