{"id":"https://openalex.org/W2649842847","doi":"https://doi.org/10.1109/tsg.2017.2717806","title":"A Distributed Cooperative Control Framework for Synchronized Reconnection of a Multi-Bus Microgrid","display_name":"A Distributed Cooperative Control Framework for Synchronized Reconnection of a Multi-Bus Microgrid","publication_year":2017,"publication_date":"2017-06-22","ids":{"openalex":"https://openalex.org/W2649842847","doi":"https://doi.org/10.1109/tsg.2017.2717806","mag":"2649842847"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2017.2717806","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2717806","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5055845984","display_name":"Di Shi","orcid":"https://orcid.org/0000-0002-1469-7887"},"institutions":[{"id":"https://openalex.org/I4210093000","display_name":"Global Energy Interconnection Research Institute North America","ror":"https://ror.org/00efwap41","country_code":"US","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4210093000"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Di Shi","raw_affiliation_strings":["GEIRI North America, San Jose, CA, USA"],"affiliations":[{"raw_affiliation_string":"GEIRI North America, San Jose, CA, USA","institution_ids":["https://openalex.org/I4210093000"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100329931","display_name":"Xi Chen","orcid":"https://orcid.org/0000-0002-3135-4114"},"institutions":[{"id":"https://openalex.org/I4210093000","display_name":"Global Energy Interconnection Research Institute North America","ror":"https://ror.org/00efwap41","country_code":"US","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4210093000"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Xi Chen","raw_affiliation_strings":["GEIRI North America, San Jose, CA, USA"],"affiliations":[{"raw_affiliation_string":"GEIRI North America, San Jose, CA, USA","institution_ids":["https://openalex.org/I4210093000"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100449967","display_name":"Zhiwei Wang","orcid":"https://orcid.org/0000-0002-9028-7476"},"institutions":[{"id":"https://openalex.org/I4210093000","display_name":"Global Energy Interconnection Research Institute North America","ror":"https://ror.org/00efwap41","country_code":"US","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4210093000"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Zhiwei Wang","raw_affiliation_strings":["GEIRI North America, San Jose, CA, USA"],"affiliations":[{"raw_affiliation_string":"GEIRI North America, San Jose, CA, USA","institution_ids":["https://openalex.org/I4210093000"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100635896","display_name":"Xiaohu Zhang","orcid":"https://orcid.org/0000-0002-0378-9305"},"institutions":[{"id":"https://openalex.org/I4210093000","display_name":"Global Energy Interconnection Research Institute North America","ror":"https://ror.org/00efwap41","country_code":"US","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4210093000"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Xiaohu Zhang","raw_affiliation_strings":["GEIRI North America, San Jose, CA, USA"],"affiliations":[{"raw_affiliation_string":"GEIRI North America, San Jose, CA, USA","institution_ids":["https://openalex.org/I4210093000"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063367376","display_name":"Zhe Yu","orcid":"https://orcid.org/0000-0003-1068-2386"},"institutions":[{"id":"https://openalex.org/I4210093000","display_name":"Global Energy Interconnection Research Institute North America","ror":"https://ror.org/00efwap41","country_code":"US","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4210093000"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Zhe Yu","raw_affiliation_strings":["GEIRI North America, San Jose, CA, USA"],"affiliations":[{"raw_affiliation_string":"GEIRI North America, San Jose, CA, USA","institution_ids":["https://openalex.org/I4210093000"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102009436","display_name":"Xinan Wang","orcid":"https://orcid.org/0000-0003-1458-8258"},"institutions":[{"id":"https://openalex.org/I4210093000","display_name":"Global Energy Interconnection Research Institute North America","ror":"https://ror.org/00efwap41","country_code":"US","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4210093000"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Xinan Wang","raw_affiliation_strings":["GEIRI North America, San Jose, CA, USA"],"affiliations":[{"raw_affiliation_string":"GEIRI North America, San Jose, CA, USA","institution_ids":["https://openalex.org/I4210093000"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5006425008","display_name":"Desong Bian","orcid":"https://orcid.org/0000-0002-1599-7961"},"institutions":[{"id":"https://openalex.org/I4210093000","display_name":"Global Energy Interconnection Research Institute North America","ror":"https://ror.org/00efwap41","country_code":"US","type":"facility","lineage":["https://openalex.org/I17442442","https://openalex.org/I4210093000"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Desong Bian","raw_affiliation_strings":["GEIRI North America, San Jose, CA, USA"],"affiliations":[{"raw_affiliation_string":"GEIRI North America, San Jose, CA, USA","institution_ids":["https://openalex.org/I4210093000"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5055845984"],"corresponding_institution_ids":["https://openalex.org/I4210093000"],"apc_list":null,"apc_paid":null,"fwci":9.6556,"has_fulltext":false,"cited_by_count":74,"citation_normalized_percentile":{"value":0.98479948,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":100},"biblio":{"volume":"9","issue":"6","first_page":"6646","last_page":"6655"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9624999761581421,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9574999809265137,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.975440263748169},{"id":"https://openalex.org/keywords/synchronization","display_name":"Synchronization (alternating current)","score":0.6803116202354431},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.6603999733924866},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6460274457931519},{"id":"https://openalex.org/keywords/synchronizer","display_name":"Synchronizer","score":0.6206467151641846},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5557801723480225},{"id":"https://openalex.org/keywords/distributed-power-generation","display_name":"Distributed power generation","score":0.5402957797050476},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.5387294292449951},{"id":"https://openalex.org/keywords/synchronization-networks","display_name":"Synchronization networks","score":0.4985206127166748},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.4366551339626312},{"id":"https://openalex.org/keywords/telecommunications-network","display_name":"Telecommunications network","score":0.42008861899375916},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.34274059534072876},{"id":"https://openalex.org/keywords/topology","display_name":"Topology (electrical circuits)","score":0.32573962211608887},{"id":"https://openalex.org/keywords/control","display_name":"Control (management)","score":0.2977003753185272},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.2950561046600342},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.25692009925842285},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.08151611685752869}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.975440263748169},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.6803116202354431},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.6603999733924866},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6460274457931519},{"id":"https://openalex.org/C66727535","wikidata":"https://www.wikidata.org/wiki/Q7662199","display_name":"Synchronizer","level":2,"score":0.6206467151641846},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5557801723480225},{"id":"https://openalex.org/C2986283658","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed power generation","level":4,"score":0.5402957797050476},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5387294292449951},{"id":"https://openalex.org/C111097370","wikidata":"https://www.wikidata.org/wiki/Q10969923","display_name":"Synchronization networks","level":4,"score":0.4985206127166748},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.4366551339626312},{"id":"https://openalex.org/C192126672","wikidata":"https://www.wikidata.org/wiki/Q1068715","display_name":"Telecommunications network","level":2,"score":0.42008861899375916},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.34274059534072876},{"id":"https://openalex.org/C184720557","wikidata":"https://www.wikidata.org/wiki/Q7825049","display_name":"Topology (electrical circuits)","level":2,"score":0.32573962211608887},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.2977003753185272},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.2950561046600342},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.25692009925842285},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.08151611685752869},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2017.2717806","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2717806","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1964728279","https://openalex.org/W1984641677","https://openalex.org/W2008249292","https://openalex.org/W2032919163","https://openalex.org/W2049040453","https://openalex.org/W2050388675","https://openalex.org/W2071780137","https://openalex.org/W2075937439","https://openalex.org/W2085846403","https://openalex.org/W2088042953","https://openalex.org/W2103608196","https://openalex.org/W2104195154","https://openalex.org/W2104658456","https://openalex.org/W2104785836","https://openalex.org/W2116526546","https://openalex.org/W2120602407","https://openalex.org/W2139055890","https://openalex.org/W2149559996","https://openalex.org/W2150679143","https://openalex.org/W2159122720","https://openalex.org/W2517305838","https://openalex.org/W2537708162","https://openalex.org/W4230102907","https://openalex.org/W4232284745","https://openalex.org/W6684033999"],"related_works":["https://openalex.org/W2604628368","https://openalex.org/W3090776330","https://openalex.org/W2147599477","https://openalex.org/W3120797254","https://openalex.org/W2527531766","https://openalex.org/W2770634535","https://openalex.org/W2392430353","https://openalex.org/W2119766332","https://openalex.org/W2153339991","https://openalex.org/W2783207883"],"abstract_inverted_index":{"One":[0],"critical":[1],"value":[2],"microgrids":[3],"brings":[4],"to":[5,15,36,42,71,86,94,151],"power":[6],"systems":[7],"is":[8],"resilience,":[9],"the":[10,18,37,54,129,137,161,164],"capability":[11],"of":[12,49,128,140,163],"being":[13],"able":[14],"island":[16],"from":[17,157],"main":[19,38],"grid":[20,39,55],"under":[21],"certain":[22],"conditions":[23],"and":[24,80,123,143],"connect":[25],"back":[26],"when":[27,68],"necessary.":[28],"Once":[29],"islanded,":[30],"a":[31,50,61,72,91,100,108,118],"microgrid":[32,74],"must":[33],"be":[34,57,87,133,147],"synchronized":[35],"before":[40],"reconnection":[41],"prevent":[43],"severe":[44],"consequences.":[45],"In":[46,111],"general,":[47],"synchronization":[48,145],"single":[51],"machine":[52],"with":[53,75,149],"can":[56,132,146],"easily":[58],"achieved":[59,148],"using":[60,121],"synchronizer.":[62],"The":[63,126],"problem":[64],"becomes":[65],"more":[66],"challenging":[67],"it":[69],"comes":[70],"multi-bus":[73,109],"multiple":[76],"distributed":[77,103,119],"generators":[78],"(DGs)":[79],"dispersed":[81],"loads.":[82],"All":[83],"DGs":[84,114],"need":[85],"properly":[88],"controlled":[89],"in":[90,117],"coordinated":[92],"way":[93],"achieve":[95],"synchronization.":[96],"This":[97],"paper":[98],"presents":[99],"novel":[101],"bi-level":[102],"cooperative":[104],"control":[105],"framework":[106],"for":[107],"microgrid.":[110],"this":[112],"framework,":[113],"work":[115],"collaboratively":[116],"manner":[120],"minimum":[122],"sparse":[124],"communication.":[125],"topology":[127],"communication":[130,152],"network":[131],"flexible":[134],"which":[135],"supports":[136],"plug-and-play":[138],"feature":[139],"microgrids.":[141],"Fast":[142],"deterministic":[144],"tolerance":[150],"latency.":[153],"Experimental":[154],"results":[155],"obtained":[156],"hardware-in-the-loop":[158],"simulation":[159],"demonstrate":[160],"effectiveness":[162],"proposed":[165],"approach.":[166]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":8},{"year":2022,"cited_by_count":10},{"year":2021,"cited_by_count":4},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":24},{"year":2018,"cited_by_count":13},{"year":2017,"cited_by_count":3}],"updated_date":"2026-01-29T23:13:10.619473","created_date":"2025-10-10T00:00:00"}
