{"id":"https://openalex.org/W2617617186","doi":"https://doi.org/10.1109/tsg.2017.2708743","title":"Protection of Smart DC Microgrid With Ring Configuration Using Parameter Estimation Approach","display_name":"Protection of Smart DC Microgrid With Ring Configuration Using Parameter Estimation Approach","publication_year":2017,"publication_date":"2017-05-26","ids":{"openalex":"https://openalex.org/W2617617186","doi":"https://doi.org/10.1109/tsg.2017.2708743","mag":"2617617186"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2017.2708743","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2708743","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5102884253","display_name":"Rabindra Mohanty","orcid":"https://orcid.org/0000-0003-3514-850X"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":true,"raw_author_name":"Rabindra Mohanty","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India"],"raw_orcid":"https://orcid.org/0000-0003-3514-850X","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5063136321","display_name":"Ashok Kumar Pradhan","orcid":"https://orcid.org/0000-0001-8438-9911"},"institutions":[{"id":"https://openalex.org/I145894827","display_name":"Indian Institute of Technology Kharagpur","ror":"https://ror.org/03w5sq511","country_code":"IN","type":"education","lineage":["https://openalex.org/I145894827"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ashok Kumar Pradhan","raw_affiliation_strings":["Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India"],"raw_orcid":"https://orcid.org/0000-0001-8438-9911","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur, India","institution_ids":["https://openalex.org/I145894827"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5102884253"],"corresponding_institution_ids":["https://openalex.org/I145894827"],"apc_list":null,"apc_paid":null,"fwci":9.5904,"has_fulltext":false,"cited_by_count":172,"citation_normalized_percentile":{"value":0.98412726,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":100},"biblio":{"volume":"9","issue":"6","first_page":"6328","last_page":"6337"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrid","display_name":"Microgrid","score":0.8622700572013855},{"id":"https://openalex.org/keywords/overcurrent","display_name":"Overcurrent","score":0.7327659130096436},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.685386061668396},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.5311689972877502},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5219109058380127},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.49854588508605957},{"id":"https://openalex.org/keywords/fault-indicator","display_name":"Fault indicator","score":0.49575528502464294},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4609464108943939},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4543364644050598},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4328058362007141},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.4139374792575836},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.41294994950294495},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.3965678811073303},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.38649749755859375},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.23110511898994446}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.8622700572013855},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.7327659130096436},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.685386061668396},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.5311689972877502},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5219109058380127},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.49854588508605957},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.49575528502464294},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4609464108943939},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4543364644050598},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4328058362007141},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.4139374792575836},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.41294994950294495},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3965678811073303},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.38649749755859375},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.23110511898994446},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2017.2708743","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2708743","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Peace, Justice and strong institutions","score":0.5699999928474426,"id":"https://metadata.un.org/sdg/16"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W943580425","https://openalex.org/W1598570594","https://openalex.org/W1626956352","https://openalex.org/W1849484999","https://openalex.org/W2007429446","https://openalex.org/W2022825392","https://openalex.org/W2029135909","https://openalex.org/W2036302375","https://openalex.org/W2051280906","https://openalex.org/W2053996716","https://openalex.org/W2068023198","https://openalex.org/W2069032722","https://openalex.org/W2073887634","https://openalex.org/W2080326549","https://openalex.org/W2089212322","https://openalex.org/W2092826219","https://openalex.org/W2098711962","https://openalex.org/W2100650888","https://openalex.org/W2103943551","https://openalex.org/W2109428143","https://openalex.org/W2111443459","https://openalex.org/W2113229722","https://openalex.org/W2115556004","https://openalex.org/W2121355385","https://openalex.org/W2124853941","https://openalex.org/W2127761430","https://openalex.org/W2135312672","https://openalex.org/W2140506556","https://openalex.org/W2142351866","https://openalex.org/W2148895869","https://openalex.org/W2158017035","https://openalex.org/W2294714195","https://openalex.org/W2304131693","https://openalex.org/W2306054012","https://openalex.org/W2339766197","https://openalex.org/W2412553497","https://openalex.org/W2497855708","https://openalex.org/W2569223404","https://openalex.org/W4232272070","https://openalex.org/W4296927671","https://openalex.org/W6636676177"],"related_works":["https://openalex.org/W2896710163","https://openalex.org/W3034608034","https://openalex.org/W1989451277","https://openalex.org/W1586801069","https://openalex.org/W3094007325","https://openalex.org/W3159420259","https://openalex.org/W2808698631","https://openalex.org/W1548783648","https://openalex.org/W1972196300","https://openalex.org/W2036302375"],"abstract_inverted_index":{"In":[0,66],"a":[1,27,30,61,75,105,109,125,160],"smart":[2],"dc":[3,31],"microgrid,":[4],"power":[5,38],"electronic":[6],"devices":[7],"limit":[8],"the":[9,40,80,83,88,91,96,165],"current":[10,73],"during":[11],"fault":[12,84,92,99,134],"and":[13,23,51,72,113,145],"therefore,":[14],"an":[15],"overcurrent-based":[16],"relaying":[17],"scheme":[18,63],"cannot":[19],"provide":[20],"required":[21],"sensitivity":[22],"selectivity":[24,59],"for":[25,118,124,132],"such":[26],"system.":[28],"For":[29,46],"microgrid":[32],"with":[33,143],"ring":[34,110,126],"configuration":[35],"having":[36],"bidirectional":[37],"flow,":[39],"protection":[41,62],"design":[42],"is":[43,64,93,130,156,169],"further":[44],"complicated.":[45],"reliable":[47],"supply":[48],"to":[49,52,171,176],"customers":[50],"avoid":[53],"unwanted":[54],"disconnection":[55],"of":[56,60,82,90,98,101,104,149],"renewable":[57],"resources,":[58],"important.":[65],"this":[67],"paper,":[68],"using":[69],"local":[70],"voltage":[71],"data,":[74],"least":[76],"square-based":[77],"technique":[78],"estimates":[79],"parameter":[81],"path,":[85],"from":[86],"which":[87],"direction":[89,97],"inferred.":[94],"Using":[95,121],"information":[100],"both":[102],"ends":[103],"line":[106],"segment":[107],"in":[108,164],"system,":[111,127],"internal":[112],"external":[114],"faults":[115],"are":[116],"discriminated":[117],"network":[119],"protection.":[120],"PSCAD/EMTDC":[122],"simulations":[123],"proposed":[128,154],"method":[129,168],"tested":[131],"various":[133],"situations":[135],"including":[136],"high":[137],"resistance":[138],"fault,":[139,141],"close-in":[140],"signals":[142],"noise,":[144],"considering":[146],"different":[147],"modes":[148],"distributed":[150],"generation":[151],"operations.":[152],"The":[153,167],"algorithm":[155],"also":[157],"validated":[158],"on":[159],"scaled-down":[161],"hardware":[162],"setup":[163],"laboratory.":[166],"found":[170],"be":[172],"more":[173],"accurate":[174],"compared":[175],"available":[177],"technique.":[178]},"counts_by_year":[{"year":2026,"cited_by_count":6},{"year":2025,"cited_by_count":20},{"year":2024,"cited_by_count":16},{"year":2023,"cited_by_count":30},{"year":2022,"cited_by_count":27},{"year":2021,"cited_by_count":26},{"year":2020,"cited_by_count":19},{"year":2019,"cited_by_count":13},{"year":2018,"cited_by_count":13},{"year":2017,"cited_by_count":2}],"updated_date":"2026-05-07T13:39:58.223016","created_date":"2025-10-10T00:00:00"}