{"id":"https://openalex.org/W2610794370","doi":"https://doi.org/10.1109/tsg.2017.2700436","title":"Load Modeling\u2014A Review","display_name":"Load Modeling\u2014A Review","publication_year":2017,"publication_date":"2017-05-02","ids":{"openalex":"https://openalex.org/W2610794370","doi":"https://doi.org/10.1109/tsg.2017.2700436","mag":"2610794370"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2017.2700436","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2700436","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://www.osti.gov/biblio/1435710","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006839669","display_name":"Anmar Arif","orcid":null},"institutions":[{"id":"https://openalex.org/I173911158","display_name":"Iowa State University","ror":"https://ror.org/04rswrd78","country_code":"US","type":"education","lineage":["https://openalex.org/I173911158"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Anmar Arif","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA"],"raw_orcid":"https://orcid.org/0000-0003-4768-4553","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA","institution_ids":["https://openalex.org/I173911158"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100659515","display_name":"Zhaoyu Wang","orcid":"https://orcid.org/0000-0003-0656-0562"},"institutions":[{"id":"https://openalex.org/I173911158","display_name":"Iowa State University","ror":"https://ror.org/04rswrd78","country_code":"US","type":"education","lineage":["https://openalex.org/I173911158"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Zhaoyu Wang","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA"],"raw_orcid":"https://orcid.org/0000-0003-0656-0562","affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Iowa State University, Ames, IA, USA","institution_ids":["https://openalex.org/I173911158"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100334399","display_name":"Jianhui Wang","orcid":"https://orcid.org/0000-0002-9716-3484"},"institutions":[{"id":"https://openalex.org/I178169726","display_name":"Southern Methodist University","ror":"https://ror.org/042tdr378","country_code":"US","type":"education","lineage":["https://openalex.org/I178169726"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jianhui Wang","raw_affiliation_strings":["Department of Electrical Engineering, Southern Methodist University, Dallas, TX, USA"],"raw_orcid":"https://orcid.org/0000-0002-9716-3484","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Southern Methodist University, Dallas, TX, USA","institution_ids":["https://openalex.org/I178169726"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5032168433","display_name":"Barry Mather","orcid":"https://orcid.org/0000-0003-4201-7292"},"institutions":[{"id":"https://openalex.org/I1297288678","display_name":"National Laboratory of the Rockies","ror":"https://ror.org/036266993","country_code":"US","type":"facility","lineage":["https://openalex.org/I1297288678","https://openalex.org/I1330989302","https://openalex.org/I2800842121"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Barry Mather","raw_affiliation_strings":["Power System Engineering Center, National Renewable Energy Laboratory, Golden, CO, USA"],"raw_orcid":"https://orcid.org/0000-0003-4201-7292","affiliations":[{"raw_affiliation_string":"Power System Engineering Center, National Renewable Energy Laboratory, Golden, CO, USA","institution_ids":["https://openalex.org/I1297288678"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009581780","display_name":"Hugo Bashualdo","orcid":null},"institutions":[{"id":"https://openalex.org/I4210137693","display_name":"Siemens (United States)","ror":"https://ror.org/04axb7e79","country_code":"US","type":"company","lineage":["https://openalex.org/I1325886976","https://openalex.org/I4210137693"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Hugo Bashualdo","raw_affiliation_strings":["Distribution Planning and Microgrids, Siemens Power Technologies International, Schenectady, NY, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Distribution Planning and Microgrids, Siemens Power Technologies International, Schenectady, NY, USA","institution_ids":["https://openalex.org/I4210137693"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5057667244","display_name":"Dongbo Zhao","orcid":"https://orcid.org/0000-0003-4401-5792"},"institutions":[{"id":"https://openalex.org/I1282105669","display_name":"Argonne National Laboratory","ror":"https://ror.org/05gvnxz63","country_code":"US","type":"facility","lineage":["https://openalex.org/I1282105669","https://openalex.org/I1330989302","https://openalex.org/I39565521","https://openalex.org/I40347166"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Dongbo Zhao","raw_affiliation_strings":["Energy Systems Division, Argonne National Laboratory, Lemont, IL, USA"],"raw_orcid":"https://orcid.org/0000-0003-4401-5792","affiliations":[{"raw_affiliation_string":"Energy Systems Division, Argonne National Laboratory, Lemont, IL, USA","institution_ids":["https://openalex.org/I1282105669"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5006839669"],"corresponding_institution_ids":["https://openalex.org/I173911158"],"apc_list":null,"apc_paid":null,"fwci":16.6594,"has_fulltext":false,"cited_by_count":474,"citation_normalized_percentile":{"value":0.99405369,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":97,"max":100},"biblio":{"volume":"9","issue":"6","first_page":"5986","last_page":"5999"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/identification","display_name":"Identification (biology)","score":0.5708091855049133},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5695017576217651},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.5023887157440186},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.4820314645767212},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.44223302602767944},{"id":"https://openalex.org/keywords/industrial-engineering","display_name":"Industrial engineering","score":0.4237481653690338},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.41770055890083313},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.35551023483276367},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.34159624576568604},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.301616907119751},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.10126179456710815}],"concepts":[{"id":"https://openalex.org/C116834253","wikidata":"https://www.wikidata.org/wiki/Q2039217","display_name":"Identification (biology)","level":2,"score":0.5708091855049133},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5695017576217651},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.5023887157440186},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.4820314645767212},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.44223302602767944},{"id":"https://openalex.org/C13736549","wikidata":"https://www.wikidata.org/wiki/Q4489420","display_name":"Industrial engineering","level":1,"score":0.4237481653690338},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.41770055890083313},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.35551023483276367},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.34159624576568604},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.301616907119751},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10126179456710815},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C59822182","wikidata":"https://www.wikidata.org/wiki/Q441","display_name":"Botany","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2017.2700436","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2700436","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:osti.gov:1435710","is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/1435710","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:osti.gov:1435710","is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/1435710","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.47999998927116394,"display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320306084","display_name":"U.S. Department of Energy","ror":"https://ror.org/01bj3aw27"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":125,"referenced_works":["https://openalex.org/W153054391","https://openalex.org/W838869738","https://openalex.org/W1482578125","https://openalex.org/W1508824406","https://openalex.org/W1533985346","https://openalex.org/W1542525473","https://openalex.org/W1596909784","https://openalex.org/W1599680004","https://openalex.org/W1681098676","https://openalex.org/W1763243278","https://openalex.org/W1816587896","https://openalex.org/W1970233907","https://openalex.org/W1978789812","https://openalex.org/W1985823269","https://openalex.org/W1986128351","https://openalex.org/W1988965504","https://openalex.org/W1993608030","https://openalex.org/W1998955322","https://openalex.org/W2004540575","https://openalex.org/W2006113179","https://openalex.org/W2011033069","https://openalex.org/W2013486252","https://openalex.org/W2015052068","https://openalex.org/W2024353911","https://openalex.org/W2025964471","https://openalex.org/W2030983323","https://openalex.org/W2031329484","https://openalex.org/W2032505229","https://openalex.org/W2038335048","https://openalex.org/W2039487050","https://openalex.org/W2039581856","https://openalex.org/W2043225372","https://openalex.org/W2050358868","https://openalex.org/W2051118139","https://openalex.org/W2061122474","https://openalex.org/W2062898426","https://openalex.org/W2063395578","https://openalex.org/W2070207746","https://openalex.org/W2072305550","https://openalex.org/W2073632737","https://openalex.org/W2075402940","https://openalex.org/W2085405268","https://openalex.org/W2090636411","https://openalex.org/W2091726522","https://openalex.org/W2094093085","https://openalex.org/W2094520960","https://openalex.org/W2099544223","https://openalex.org/W2100291404","https://openalex.org/W2101902173","https://openalex.org/W2103910919","https://openalex.org/W2104078524","https://openalex.org/W2105402504","https://openalex.org/W2106748933","https://openalex.org/W2106827477","https://openalex.org/W2107876952","https://openalex.org/W2108829714","https://openalex.org/W2108915352","https://openalex.org/W2115932725","https://openalex.org/W2116751355","https://openalex.org/W2117834774","https://openalex.org/W2118448684","https://openalex.org/W2121422569","https://openalex.org/W2121592925","https://openalex.org/W2121741880","https://openalex.org/W2123585175","https://openalex.org/W2124575294","https://openalex.org/W2129109606","https://openalex.org/W2135663343","https://openalex.org/W2136093349","https://openalex.org/W2138781031","https://openalex.org/W2139477877","https://openalex.org/W2139822278","https://openalex.org/W2141836663","https://openalex.org/W2144012167","https://openalex.org/W2145616301","https://openalex.org/W2146119978","https://openalex.org/W2148406707","https://openalex.org/W2148438951","https://openalex.org/W2152456563","https://openalex.org/W2152560253","https://openalex.org/W2153744658","https://openalex.org/W2155517475","https://openalex.org/W2156601564","https://openalex.org/W2163886815","https://openalex.org/W2165305513","https://openalex.org/W2166226698","https://openalex.org/W2166773501","https://openalex.org/W2168037395","https://openalex.org/W2168250135","https://openalex.org/W2169108730","https://openalex.org/W2170288846","https://openalex.org/W2171126558","https://openalex.org/W2257803164","https://openalex.org/W2325291257","https://openalex.org/W2327078593","https://openalex.org/W2329114217","https://openalex.org/W2339010835","https://openalex.org/W2349246318","https://openalex.org/W2410384633","https://openalex.org/W2421251318","https://openalex.org/W2424632056","https://openalex.org/W2495418466","https://openalex.org/W2513160181","https://openalex.org/W2539669639","https://openalex.org/W2542932354","https://openalex.org/W2554200450","https://openalex.org/W2555036027","https://openalex.org/W2557236490","https://openalex.org/W2557435886","https://openalex.org/W2568392743","https://openalex.org/W2603752983","https://openalex.org/W3099860909","https://openalex.org/W3143068938","https://openalex.org/W4244237061","https://openalex.org/W4244419253","https://openalex.org/W4244656286","https://openalex.org/W4247689375","https://openalex.org/W6606230802","https://openalex.org/W6630260330","https://openalex.org/W6632414551","https://openalex.org/W6684800988","https://openalex.org/W6684961381","https://openalex.org/W6714791812","https://openalex.org/W6730110052","https://openalex.org/W6980758457"],"related_works":["https://openalex.org/W2357256365","https://openalex.org/W2348502264","https://openalex.org/W2365486383","https://openalex.org/W2362059367","https://openalex.org/W2350084742","https://openalex.org/W2901443725","https://openalex.org/W2357988862","https://openalex.org/W2155742919","https://openalex.org/W2532099551","https://openalex.org/W1914681266"],"abstract_inverted_index":{"Load":[0,20,51],"modeling":[1,16,52,93],"has":[2,53],"significant":[3],"impact":[4],"on":[5,14,117],"power":[6],"system":[7],"studies.":[8],"This":[9],"paper":[10],"presents":[11],"a":[12,86,114],"review":[13,90],"load":[15,75,92,133],"and":[17,31,48,67,79,95,107,122,125,129],"identification":[18],"techniques.":[19],"models":[21,76],"can":[22],"be":[23],"classified":[24],"into":[25],"two":[26,38],"broad":[27],"categories:":[28],"1)":[29,46],"static":[30],"2)":[32,49],"dynamic":[33],"models,":[34],"while":[35],"there":[36],"are":[37,77],"types":[39],"of":[40,61],"approaches":[41],"to":[42,88,100],"identify":[43],"model":[44],"parameters:":[45],"measurement-based":[47],"component-based.":[50],"received":[54],"more":[55],"attention":[56],"in":[57,132],"recent":[58],"years":[59],"because":[60],"the":[62,72,102,118],"renewable":[63],"integration,":[64],"demand-side":[65],"management,":[66],"smart":[68],"metering":[69],"devices.":[70],"However,":[71],"commonly":[73],"used":[74],"outdated,":[78],"cannot":[80],"represent":[81],"emerging":[82],"loads.":[83],"There":[84],"is":[85],"need":[87],"systematically":[89],"existing":[91,127],"techniques":[94],"suggest":[96],"future":[97],"research":[98,120],"directions":[99],"meet":[101],"increasing":[103],"interests":[104],"from":[105],"industry":[106,123],"academia.":[108],"In":[109],"this":[110],"paper,":[111],"we":[112],"provide":[113],"thorough":[115],"survey":[116],"academic":[119],"progress":[121],"practices,":[124],"highlight":[126],"issues":[128],"new":[130],"trends":[131],"modeling.":[134]},"counts_by_year":[{"year":2026,"cited_by_count":12},{"year":2025,"cited_by_count":68},{"year":2024,"cited_by_count":77},{"year":2023,"cited_by_count":72},{"year":2022,"cited_by_count":59},{"year":2021,"cited_by_count":72},{"year":2020,"cited_by_count":50},{"year":2019,"cited_by_count":45},{"year":2018,"cited_by_count":15},{"year":2017,"cited_by_count":4}],"updated_date":"2026-05-04T08:30:34.212998","created_date":"2025-10-10T00:00:00"}
