{"id":"https://openalex.org/W2605127651","doi":"https://doi.org/10.1109/tsg.2017.2691782","title":"Multi-Physics Graphical Model-Based Fault Detection and Isolation in Wind Turbines","display_name":"Multi-Physics Graphical Model-Based Fault Detection and Isolation in Wind Turbines","publication_year":2017,"publication_date":"2017-04-07","ids":{"openalex":"https://openalex.org/W2605127651","doi":"https://doi.org/10.1109/tsg.2017.2691782","mag":"2605127651"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2017.2691782","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2691782","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5060273324","display_name":"Aslan Mojallal","orcid":"https://orcid.org/0000-0001-8732-526X"},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":true,"raw_author_name":"Aslan Mojallal","raw_affiliation_strings":["School of Electrical Engineering and Computer Science, Washington State University, Pullman, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Computer Science, Washington State University, Pullman, WA, USA","institution_ids":["https://openalex.org/I72951846"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5075994721","display_name":"Saeed Lotfifard","orcid":"https://orcid.org/0000-0002-1818-1212"},"institutions":[{"id":"https://openalex.org/I72951846","display_name":"Washington State University","ror":"https://ror.org/05dk0ce17","country_code":"US","type":"education","lineage":["https://openalex.org/I72951846"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Saeed Lotfifard","raw_affiliation_strings":["School of Electrical Engineering and Computer Science, Washington State University, Pullman, WA, USA"],"raw_orcid":"https://orcid.org/0000-0002-1818-1212","affiliations":[{"raw_affiliation_string":"School of Electrical Engineering and Computer Science, Washington State University, Pullman, WA, USA","institution_ids":["https://openalex.org/I72951846"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5060273324"],"corresponding_institution_ids":["https://openalex.org/I72951846"],"apc_list":null,"apc_paid":null,"fwci":3.058,"has_fulltext":false,"cited_by_count":38,"citation_normalized_percentile":{"value":0.91482601,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"9","issue":"6","first_page":"5599","last_page":"5612"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13050","display_name":"Oil and Gas Production Techniques","score":0.9871000051498413,"subfield":{"id":"https://openalex.org/subfields/2212","display_name":"Ocean Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/wind-power","display_name":"Wind power","score":0.7484309673309326},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.720471203327179},{"id":"https://openalex.org/keywords/turbine","display_name":"Turbine","score":0.5590739846229553},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.5085126161575317},{"id":"https://openalex.org/keywords/bond-graph","display_name":"Bond graph","score":0.5012414455413818},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.48682254552841187},{"id":"https://openalex.org/keywords/induction-generator","display_name":"Induction generator","score":0.48522472381591797},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.4603222906589508},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4547107517719269},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"Condition monitoring","score":0.4415455460548401},{"id":"https://openalex.org/keywords/control-engineering","display_name":"Control engineering","score":0.440765917301178},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3441278338432312},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.2688806653022766},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.25858038663864136},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.24191606044769287},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.1039518415927887}],"concepts":[{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.7484309673309326},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.720471203327179},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.5590739846229553},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5085126161575317},{"id":"https://openalex.org/C187593909","wikidata":"https://www.wikidata.org/wiki/Q838024","display_name":"Bond graph","level":2,"score":0.5012414455413818},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.48682254552841187},{"id":"https://openalex.org/C98716924","wikidata":"https://www.wikidata.org/wiki/Q752750","display_name":"Induction generator","level":3,"score":0.48522472381591797},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.4603222906589508},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4547107517719269},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.4415455460548401},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.440765917301178},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3441278338432312},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2688806653022766},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.25858038663864136},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.24191606044769287},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.1039518415927887},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2017.2691782","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2017.2691782","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":43,"referenced_works":["https://openalex.org/W304260394","https://openalex.org/W1486311415","https://openalex.org/W1488653071","https://openalex.org/W1533902227","https://openalex.org/W1585835307","https://openalex.org/W1780900385","https://openalex.org/W1944055092","https://openalex.org/W1970750957","https://openalex.org/W1971991733","https://openalex.org/W1978110380","https://openalex.org/W1980303241","https://openalex.org/W1988499271","https://openalex.org/W1992578106","https://openalex.org/W1996469419","https://openalex.org/W2007297199","https://openalex.org/W2026743245","https://openalex.org/W2030219727","https://openalex.org/W2031123740","https://openalex.org/W2053111582","https://openalex.org/W2061543490","https://openalex.org/W2071802306","https://openalex.org/W2073077077","https://openalex.org/W2085830749","https://openalex.org/W2087183979","https://openalex.org/W2101401941","https://openalex.org/W2104666153","https://openalex.org/W2111708723","https://openalex.org/W2113307062","https://openalex.org/W2123565208","https://openalex.org/W2143057388","https://openalex.org/W2151666088","https://openalex.org/W2153412203","https://openalex.org/W2166696190","https://openalex.org/W2232066024","https://openalex.org/W2265248459","https://openalex.org/W2335415707","https://openalex.org/W2487628251","https://openalex.org/W2490116147","https://openalex.org/W3003386406","https://openalex.org/W3147537413","https://openalex.org/W4254089362","https://openalex.org/W6676711873","https://openalex.org/W7072120841"],"related_works":["https://openalex.org/W3009669764","https://openalex.org/W1958094387","https://openalex.org/W2032170356","https://openalex.org/W2371731813","https://openalex.org/W2358330211","https://openalex.org/W2367105195","https://openalex.org/W2391669314","https://openalex.org/W2570127249","https://openalex.org/W2023578373","https://openalex.org/W2065965834"],"abstract_inverted_index":{"Early":[0],"detection":[1,79,184],"and":[2,16,21,41,59,68,80,109,182,185,190],"isolation":[3,81],"of":[4,13,55,95,112,143,158,170,176,187],"faults":[5,171,192],"in":[6,140,165,180],"wind":[7,14,91,97],"power":[8,56],"generators":[9],"increases":[10],"the":[11,96,113,129,138,141,156,163,177,196],"availability":[12],"turbines":[15,25],"reduces":[17],"their":[18],"down":[19],"times":[20],"maintenance":[22],"costs.":[23],"Wind":[24],"constitute":[26,45],"a":[27,74],"complex":[28],"system":[29],"that":[30,105],"includes":[31],"sub-systems":[32],"from":[33],"different":[34],"physical":[35],"domains":[36],"such":[37,62],"as":[38,63],"electrical,":[39,189],"mechanical,":[40,188],"hydraulic":[42,191],"systems.":[43],"They":[44],"hybrid":[46,102],"dynamical":[47],"systems":[48],"comprising":[49],"discrete":[50],"parts":[51,61],"due":[52,167],"to":[53,121,154,168],"presence":[54],"electronic":[57],"switches":[58],"continuous":[60],"induction":[64,89],"machines,":[65],"pitch":[66],"actuator":[67],"mechanical":[69],"drive-train.":[70],"In":[71],"this":[72],"paper,":[73],"multi-physics":[75],"graphical":[76],"model-based":[77],"fault":[78],"(FDI)":[82],"method":[83,117,179],"is":[84,99,118,134,152,193],"developed":[85,100,130,153],"for":[86],"doubly":[87],"fed":[88],"generator-based":[90],"turbines.":[92],"The":[93,132,174],"model":[94],"turbine":[98],"using":[101],"bond-graph":[103],"theory":[104],"captures":[106],"causal,":[107],"temporal,":[108],"structural":[110],"properties":[111],"system.":[114],"Causality":[115],"inversion":[116],"then":[119],"employed":[120],"derive":[122],"analytical":[123],"redundancy":[124],"relations":[125],"(ARRs)":[126],"based":[127,136,148,160],"on":[128,137,149,161],"model.":[131],"FDI":[133],"performed":[135],"changes":[139],"values":[142,157],"ARRs.":[144],"A":[145],"systematic":[146],"approach":[147],"Chi-square":[150],"criterion":[151],"determine":[155],"thresholds,":[159],"which":[162],"change":[164],"ARRs":[166],"occurrence":[169],"are":[172],"detected.":[173],"capability":[175],"proposed":[178],"accurate":[181],"fast":[183],"identification":[186],"demonstrated":[194],"by":[195],"simulation":[197],"results.":[198]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":3},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
