{"id":"https://openalex.org/W2565189990","doi":"https://doi.org/10.1109/tsg.2016.2639559","title":"Super-Positioning of Voltage Sources for Fast Assessment of Wide-Area Th\u00e9venin Equivalents","display_name":"Super-Positioning of Voltage Sources for Fast Assessment of Wide-Area Th\u00e9venin Equivalents","publication_year":2016,"publication_date":"2016-12-17","ids":{"openalex":"https://openalex.org/W2565189990","doi":"https://doi.org/10.1109/tsg.2016.2639559","mag":"2565189990"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2016.2639559","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2016.2639559","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://orbit.dtu.dk/en/publications/730f8d48-fbaa-4758-b56d-ebc18ee553b0","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5038716728","display_name":"Jakob Glarbo M\u00f8ller","orcid":"https://orcid.org/0000-0003-2495-627X"},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":true,"raw_author_name":"Jakob Glarbo Moller","raw_affiliation_strings":["Center for Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark"],"raw_orcid":"https://orcid.org/0000-0003-2495-627X","affiliations":[{"raw_affiliation_string":"Center for Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009544684","display_name":"Hj\u00f6rtur J\u00f3hannsson","orcid":null},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Hjortur Johannsson","raw_affiliation_strings":["Center for Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5046038767","display_name":"Jacob \u00d8stergaard","orcid":"https://orcid.org/0000-0002-9416-2857"},"institutions":[{"id":"https://openalex.org/I96673099","display_name":"Technical University of Denmark","ror":"https://ror.org/04qtj9h94","country_code":"DK","type":"education","lineage":["https://openalex.org/I96673099"]}],"countries":["DK"],"is_corresponding":false,"raw_author_name":"Jacob Ostergaard","raw_affiliation_strings":["Center for Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Center for Electric Power and Energy, Technical University of Denmark, Kongens Lyngby, Denmark","institution_ids":["https://openalex.org/I96673099"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5038716728"],"corresponding_institution_ids":["https://openalex.org/I96673099"],"apc_list":null,"apc_paid":null,"fwci":4.1149,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.93788342,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"8","issue":"3","first_page":"1488","last_page":"1493"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11750","display_name":"Phytoplasmas and Hemiptera pathogens","score":0.9532999992370605,"subfield":{"id":"https://openalex.org/subfields/1110","display_name":"Plant Science"},"field":{"id":"https://openalex.org/fields/11","display_name":"Agricultural and Biological Sciences"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},"topics":[{"id":"https://openalex.org/T11750","display_name":"Phytoplasmas and Hemiptera pathogens","score":0.9532999992370605,"subfield":{"id":"https://openalex.org/subfields/1110","display_name":"Plant Science"},"field":{"id":"https://openalex.org/fields/11","display_name":"Agricultural and Biological Sciences"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T12477","display_name":"Toxin Mechanisms and Immunotoxins","score":0.945900022983551,"subfield":{"id":"https://openalex.org/subfields/2403","display_name":"Immunology"},"field":{"id":"https://openalex.org/fields/24","display_name":"Immunology and Microbiology"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10923","display_name":"Force Microscopy Techniques and Applications","score":0.9401000142097473,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5458264350891113},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5331119298934937},{"id":"https://openalex.org/keywords/th\u00e9venins-theorem","display_name":"Th\u00e9venin's theorem","score":0.5173782110214233},{"id":"https://openalex.org/keywords/equivalent","display_name":"Equivalent","score":0.4333828091621399},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3668535351753235},{"id":"https://openalex.org/keywords/equivalent-circuit","display_name":"Equivalent circuit","score":0.26989126205444336},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.26204657554626465}],"concepts":[{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5458264350891113},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5331119298934937},{"id":"https://openalex.org/C540940223","wikidata":"https://www.wikidata.org/wiki/Q241868","display_name":"Th\u00e9venin's theorem","level":4,"score":0.5173782110214233},{"id":"https://openalex.org/C131857375","wikidata":"https://www.wikidata.org/wiki/Q36384","display_name":"Equivalent","level":2,"score":0.4333828091621399},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3668535351753235},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.26989126205444336},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.26204657554626465},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tsg.2016.2639559","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2016.2639559","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:pure.atira.dk:publications/36fe7c0c-dc9f-49d8-9cde-faaf5a8b135c","is_oa":false,"landing_page_url":"https://orbit.dtu.dk/en/publications/36fe7c0c-dc9f-49d8-9cde-faaf5a8b135c","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"M\u00f8ller , J G , J\u00f3hannsson , H &amp; \u00d8stergaard , J 2017 , ' Super-Positioning of Voltage Sources for Fast Assessment of Wide-Area Th\u00e9venin Equivalents ' , IEEE Transactions on Smart Grid , vol. 8 , no. 3 , pp. 1488-1493 . https://doi.org/10.1109/TSG.2016.2639559","raw_type":"article"},{"id":"pmh:oai:pure.atira.dk:publications/730f8d48-fbaa-4758-b56d-ebc18ee553b0","is_oa":true,"landing_page_url":"https://orbit.dtu.dk/en/publications/730f8d48-fbaa-4758-b56d-ebc18ee553b0","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"M\u00f8ller , J G , J\u00f3hannsson , H &amp; \u00d8stergaard , J 2018 , Super-Positioning of Voltage Sources for Fast Assessment of Wide-Area Th\u00e9venin Equivalents . in Proceedings of the 2018 IEEE PES General Meeting . IEEE , 2018 IEEE Power &amp; Energy Society General Meeting , Portland , Oregon , United States , 05/08/2018 . https://doi.org/10.1109/PESGM.2018.8585962","raw_type":"contributionToPeriodical"}],"best_oa_location":{"id":"pmh:oai:pure.atira.dk:publications/730f8d48-fbaa-4758-b56d-ebc18ee553b0","is_oa":true,"landing_page_url":"https://orbit.dtu.dk/en/publications/730f8d48-fbaa-4758-b56d-ebc18ee553b0","pdf_url":null,"source":{"id":"https://openalex.org/S4306400705","display_name":"Technical University of Denmark, DTU Orbit (Technical University of Denmark, DTU)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I96673099","host_organization_name":"Technical University of Denmark","host_organization_lineage":["https://openalex.org/I96673099"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"M\u00f8ller , J G , J\u00f3hannsson , H &amp; \u00d8stergaard , J 2018 , Super-Positioning of Voltage Sources for Fast Assessment of Wide-Area Th\u00e9venin Equivalents . in Proceedings of the 2018 IEEE PES General Meeting . IEEE , 2018 IEEE Power &amp; Energy Society General Meeting , Portland , Oregon , United States , 05/08/2018 . https://doi.org/10.1109/PESGM.2018.8585962","raw_type":"contributionToPeriodical"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G6840857211","display_name":null,"funder_award_id":"11-116794","funder_id":"https://openalex.org/F4320309756","funder_display_name":"Strategiske Forskningsr\u00e5d"}],"funders":[{"id":"https://openalex.org/F4320309756","display_name":"Strategiske Forskningsr\u00e5d","ror":"https://ror.org/03ge1nb22"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":20,"referenced_works":["https://openalex.org/W1484104892","https://openalex.org/W1520511539","https://openalex.org/W1542938076","https://openalex.org/W1680215138","https://openalex.org/W1964930223","https://openalex.org/W1975722686","https://openalex.org/W2035579008","https://openalex.org/W2035769758","https://openalex.org/W2043665359","https://openalex.org/W2058692462","https://openalex.org/W2068969699","https://openalex.org/W2082292996","https://openalex.org/W2099249167","https://openalex.org/W2121322499","https://openalex.org/W2139081281","https://openalex.org/W2146413803","https://openalex.org/W2160447890","https://openalex.org/W2168841426","https://openalex.org/W2539809039","https://openalex.org/W2962910558"],"related_works":["https://openalex.org/W4391375266","https://openalex.org/W2899084033","https://openalex.org/W2748952813","https://openalex.org/W2363309121","https://openalex.org/W2136625389","https://openalex.org/W1534888232","https://openalex.org/W2032800015","https://openalex.org/W1996059475","https://openalex.org/W4403297039","https://openalex.org/W2032045075"],"abstract_inverted_index":{"A":[0,17],"method":[1,21,91],"for":[2,44,92],"superimposing":[3],"voltage":[4],"sources":[5],"is":[6,22,40,51,62],"sought":[7],"optimized":[8],"by":[9],"using":[10],"a":[11,54,77],"sparse":[12],"triangular":[13],"solver":[14],"and":[15,33,42,60],"multiprocessing.":[16,47],"revision":[18],"to":[19,64],"the":[20,29,69,88],"suggested":[23],"which":[24],"exploits":[25],"Schur's":[26],"complement":[27],"of":[28,36,56,79],"network":[30],"admittance":[31],"matrix":[32],"optimal":[34],"re-use":[35],"computations.":[37],"The":[38,48,72],"algorithm":[39,50,73],"implemented":[41],"parallelized":[43],"shared":[45],"memory":[46],"proposed":[49],"tested":[52],"on":[53,82],"collection":[55],"large":[57],"test":[58],"systems":[59],"performance":[61],"found":[63],"be":[65],"significantly":[66],"better":[67],"than":[68],"reference":[70],"method.":[71],"will":[74],"thereby":[75],"facilitate":[76],"speed-up":[78],"methods":[80],"relying":[81],"Th\u00e9venin":[83,89],"equivalent":[84,90],"representation":[85],"such":[86],"as":[87],"contingency":[93],"assessment.":[94]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":2}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}