{"id":"https://openalex.org/W2515472799","doi":"https://doi.org/10.1109/tsg.2016.2607318","title":"A D-S Evidence Theory-Based Relay Protection System Hidden Failures Detection Method in Smart Grid","display_name":"A D-S Evidence Theory-Based Relay Protection System Hidden Failures Detection Method in Smart Grid","publication_year":2016,"publication_date":"2016-09-08","ids":{"openalex":"https://openalex.org/W2515472799","doi":"https://doi.org/10.1109/tsg.2016.2607318","mag":"2515472799"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2016.2607318","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2016.2607318","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5017100899","display_name":"Zaibin Jiao","orcid":"https://orcid.org/0000-0002-2951-0077"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zaibin Jiao","raw_affiliation_strings":["School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031402658","display_name":"Heteng Gong","orcid":null},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Heteng Gong","raw_affiliation_strings":["School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I87445476"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100365575","display_name":"Yifei Wang","orcid":"https://orcid.org/0000-0002-0848-9977"},"institutions":[{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yifei Wang","raw_affiliation_strings":["School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I87445476"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5017100899"],"corresponding_institution_ids":["https://openalex.org/I87445476"],"apc_list":null,"apc_paid":null,"fwci":4.8581,"has_fulltext":false,"cited_by_count":55,"citation_normalized_percentile":{"value":0.95188655,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":95,"max":99},"biblio":{"volume":"9","issue":"3","first_page":"2118","last_page":"2126"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.9987000226974487,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11598","display_name":"Internet Traffic Analysis and Secure E-voting","score":0.9933000206947327,"subfield":{"id":"https://openalex.org/subfields/1702","display_name":"Artificial Intelligence"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/backup","display_name":"Backup","score":0.923092246055603},{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.842973530292511},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.667380154132843},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.6438700556755066},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.6244106888771057},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5698671340942383},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.534457802772522},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5310519337654114},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.51786208152771},{"id":"https://openalex.org/keywords/alarm","display_name":"ALARM","score":0.45338428020477295},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.42749008536338806},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3852486312389374},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.3568747043609619},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.2816583216190338},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.11534422636032104},{"id":"https://openalex.org/keywords/database","display_name":"Database","score":0.07850408554077148}],"concepts":[{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.923092246055603},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.842973530292511},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.667380154132843},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.6438700556755066},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.6244106888771057},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5698671340942383},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.534457802772522},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5310519337654114},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.51786208152771},{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.45338428020477295},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.42749008536338806},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3852486312389374},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.3568747043609619},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2816583216190338},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.11534422636032104},{"id":"https://openalex.org/C77088390","wikidata":"https://www.wikidata.org/wiki/Q8513","display_name":"Database","level":1,"score":0.07850408554077148},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2016.2607318","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2016.2607318","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1501248109","https://openalex.org/W1554342666","https://openalex.org/W1914681266","https://openalex.org/W1991416024","https://openalex.org/W2023080605","https://openalex.org/W2055265388","https://openalex.org/W2079986672","https://openalex.org/W2097771670","https://openalex.org/W2111038504","https://openalex.org/W2114463407","https://openalex.org/W2115348886","https://openalex.org/W2122058173","https://openalex.org/W2140193829","https://openalex.org/W2155742919","https://openalex.org/W2543765459","https://openalex.org/W2797148637","https://openalex.org/W4229914887","https://openalex.org/W6640178441","https://openalex.org/W6678582155"],"related_works":["https://openalex.org/W2018175133","https://openalex.org/W2124906373","https://openalex.org/W2349410032","https://openalex.org/W2391106504","https://openalex.org/W1964318283","https://openalex.org/W2320970856","https://openalex.org/W2075328848","https://openalex.org/W2362189447","https://openalex.org/W2359579292","https://openalex.org/W2132485090"],"abstract_inverted_index":{"Hidden":[0],"failures":[1,68,126,158],"in":[2,127,159,181],"relay":[3,36,74,128,160],"protection":[4,37,75,129,161],"systems":[5,30,40,130,162,180],"are":[6,131],"the":[7,12,71,91,98,108,115,134,137,143,175],"primary":[8,92],"factors":[9],"for":[10,66,123],"triggering":[11],"cascading":[13],"outages":[14],"and":[15,52,88,93,163],"bulk":[16],"blackouts":[17],"of":[18,47,73,86,136,170,178],"power":[19,29,179],"systems,":[20],"but":[21],"it":[22,168],"is":[23,82,104,140,169],"difficult":[24],"to":[25,43,173],"detect":[26,156],"these":[27],"when":[28],"operate":[31],"normally.":[32],"In":[33,77],"smart":[34,182],"grids,":[35],"management":[38],"information":[39],"allow":[41],"us":[42],"obtain":[44],"many":[45],"sequence":[46],"event":[48],"records":[49],"under":[50],"disturbances":[51],"faulty":[53],"conditions.":[54],"By":[55],"studying":[56],"such":[57],"record":[58],"information,":[59],"this":[60,78,153],"paper":[61],"proposes":[62],"a":[63],"detection":[64,121],"method":[65,154],"hidden":[67,125,157],"based":[69],"on":[70,142],"features":[72],"systems.":[76],"method,":[79],"certain":[80],"evidence":[81,103,116,119],"constructed":[83,105],"by":[84,106,112],"analysis":[85],"redundancy":[87],"coordination":[89],"between":[90],"backup":[94,99],"protections":[95],"or":[96],"within":[97],"protection.":[100],"Meanwhile,":[101],"uncertain":[102],"utilizing":[107],"fault":[109],"location.":[110],"Then,":[111],"combining":[113],"all":[114],"with":[117],"D-S":[118],"theory,":[120],"criteria":[122],"detecting":[124],"presented.":[132],"Last,":[133],"effectiveness":[135],"proposed":[138],"algorithm":[139],"verified":[141],"IEEE":[144],"39":[145],"bus":[146],"system":[147],"case.":[148],"The":[149],"results":[150],"indicate":[151],"that":[152],"can":[155],"send":[164],"alarm":[165],"information.":[166],"Thus,":[167],"great":[171],"importance":[172],"ensure":[174],"security":[176],"operation":[177],"grids.":[183]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":9},{"year":2023,"cited_by_count":8},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":9},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":5}],"updated_date":"2026-04-15T08:11:43.952461","created_date":"2025-10-10T00:00:00"}
