{"id":"https://openalex.org/W2516566940","doi":"https://doi.org/10.1109/tsg.2016.2598754","title":"Developing a Two-Level Framework for Residential Energy Management","display_name":"Developing a Two-Level Framework for Residential Energy Management","publication_year":2016,"publication_date":"2016-01-01","ids":{"openalex":"https://openalex.org/W2516566940","doi":"https://doi.org/10.1109/tsg.2016.2598754","mag":"2516566940"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2016.2598754","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2016.2598754","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040760270","display_name":"Mohammad Rastegar","orcid":"https://orcid.org/0000-0001-9056-6769"},"institutions":[{"id":"https://openalex.org/I166459259","display_name":"Shiraz University","ror":"https://ror.org/028qtbk54","country_code":"IR","type":"education","lineage":["https://openalex.org/I166459259"]}],"countries":["IR"],"is_corresponding":true,"raw_author_name":"Mohammad Rastegar","raw_affiliation_strings":["School of Electrical and Computer Engineering, Shiraz University, Shiraz, Iran"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Computer Engineering, Shiraz University, Shiraz, Iran","institution_ids":["https://openalex.org/I166459259"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5038158100","display_name":"Mahmud Fotuhi\u2010Firuzabad","orcid":"https://orcid.org/0000-0002-5507-9938"},"institutions":[{"id":"https://openalex.org/I133529467","display_name":"Sharif University of Technology","ror":"https://ror.org/024c2fq17","country_code":"IR","type":"education","lineage":["https://openalex.org/I133529467"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Mahmud Fotuhi-Firuzabad","raw_affiliation_strings":["Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran"],"raw_orcid":"https://orcid.org/0000-0002-5507-9938","affiliations":[{"raw_affiliation_string":"Center of Excellence in Power System Control and Management, Sharif University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I133529467"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5005646619","display_name":"Moein Moeini\u2010Aghtaie","orcid":"https://orcid.org/0000-0002-7656-6807"},"institutions":[{"id":"https://openalex.org/I133529467","display_name":"Sharif University of Technology","ror":"https://ror.org/024c2fq17","country_code":"IR","type":"education","lineage":["https://openalex.org/I133529467"]}],"countries":["IR"],"is_corresponding":false,"raw_author_name":"Moein Moeini- Aghtaie","raw_affiliation_strings":["Sharif Energy Research Institute, Sharif University of Technology, Tehran, Iran"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sharif Energy Research Institute, Sharif University of Technology, Tehran, Iran","institution_ids":["https://openalex.org/I133529467"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5040760270"],"corresponding_institution_ids":["https://openalex.org/I166459259"],"apc_list":null,"apc_paid":null,"fwci":4.8352,"has_fulltext":false,"cited_by_count":62,"citation_normalized_percentile":{"value":0.95448683,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":95,"max":99},"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"1"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9958999752998352,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10768","display_name":"Electric Vehicles and Infrastructure","score":0.995199978351593,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.7103607058525085},{"id":"https://openalex.org/keywords/payment","display_name":"Payment","score":0.5979463458061218},{"id":"https://openalex.org/keywords/scheduling","display_name":"Scheduling (production processes)","score":0.5838311910629272},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5638397932052612},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"Energy consumption","score":0.5378355979919434},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.5370188355445862},{"id":"https://openalex.org/keywords/load-management","display_name":"Load management","score":0.530188262462616},{"id":"https://openalex.org/keywords/energy-management","display_name":"Energy management","score":0.529687225818634},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.5219742059707642},{"id":"https://openalex.org/keywords/energy-management-system","display_name":"Energy management system","score":0.48428815603256226},{"id":"https://openalex.org/keywords/operator","display_name":"Operator (biology)","score":0.47764718532562256},{"id":"https://openalex.org/keywords/load-profile","display_name":"Load profile","score":0.4445958733558655},{"id":"https://openalex.org/keywords/operations-research","display_name":"Operations research","score":0.4270588159561157},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.3921404182910919},{"id":"https://openalex.org/keywords/energy","display_name":"Energy (signal processing)","score":0.29804325103759766},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.23089319467544556},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.12418997287750244},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.09329435229301453}],"concepts":[{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.7103607058525085},{"id":"https://openalex.org/C145097563","wikidata":"https://www.wikidata.org/wiki/Q1148747","display_name":"Payment","level":2,"score":0.5979463458061218},{"id":"https://openalex.org/C206729178","wikidata":"https://www.wikidata.org/wiki/Q2271896","display_name":"Scheduling (production processes)","level":2,"score":0.5838311910629272},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5638397932052612},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.5378355979919434},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.5370188355445862},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.530188262462616},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.529687225818634},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.5219742059707642},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.48428815603256226},{"id":"https://openalex.org/C17020691","wikidata":"https://www.wikidata.org/wiki/Q139677","display_name":"Operator (biology)","level":5,"score":0.47764718532562256},{"id":"https://openalex.org/C2777908891","wikidata":"https://www.wikidata.org/wiki/Q1806775","display_name":"Load profile","level":3,"score":0.4445958733558655},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.4270588159561157},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3921404182910919},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.29804325103759766},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.23089319467544556},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.12418997287750244},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.09329435229301453},{"id":"https://openalex.org/C104317684","wikidata":"https://www.wikidata.org/wiki/Q7187","display_name":"Gene","level":2,"score":0.0},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C86339819","wikidata":"https://www.wikidata.org/wiki/Q407384","display_name":"Transcription factor","level":3,"score":0.0},{"id":"https://openalex.org/C136764020","wikidata":"https://www.wikidata.org/wiki/Q466","display_name":"World Wide Web","level":1,"score":0.0},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C55493867","wikidata":"https://www.wikidata.org/wiki/Q7094","display_name":"Biochemistry","level":1,"score":0.0},{"id":"https://openalex.org/C158448853","wikidata":"https://www.wikidata.org/wiki/Q425218","display_name":"Repressor","level":4,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2016.2598754","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2016.2598754","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.9100000262260437,"id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":38,"referenced_works":["https://openalex.org/W1595498733","https://openalex.org/W1968167335","https://openalex.org/W1984560471","https://openalex.org/W1985849528","https://openalex.org/W2002506366","https://openalex.org/W2009878557","https://openalex.org/W2021464726","https://openalex.org/W2024485885","https://openalex.org/W2025218579","https://openalex.org/W2037607291","https://openalex.org/W2039856804","https://openalex.org/W2040522043","https://openalex.org/W2042454807","https://openalex.org/W2044982174","https://openalex.org/W2045622192","https://openalex.org/W2046207811","https://openalex.org/W2046463737","https://openalex.org/W2050683383","https://openalex.org/W2054988483","https://openalex.org/W2054989445","https://openalex.org/W2057111548","https://openalex.org/W2062564430","https://openalex.org/W2064469609","https://openalex.org/W2068060907","https://openalex.org/W2075709523","https://openalex.org/W2079585583","https://openalex.org/W2094414566","https://openalex.org/W2094490323","https://openalex.org/W2095508122","https://openalex.org/W2099144109","https://openalex.org/W2104093457","https://openalex.org/W2107991856","https://openalex.org/W2110330152","https://openalex.org/W2113138664","https://openalex.org/W2122723365","https://openalex.org/W2135797872","https://openalex.org/W2141659147","https://openalex.org/W2332901540"],"related_works":["https://openalex.org/W2522559011","https://openalex.org/W2749199243","https://openalex.org/W2392147676","https://openalex.org/W2548554710","https://openalex.org/W2785674290","https://openalex.org/W4205838918","https://openalex.org/W1998413294","https://openalex.org/W2977117508","https://openalex.org/W2990374856","https://openalex.org/W39487273"],"abstract_inverted_index":{"Residential":[0],"energy":[1,14,23],"management":[2],"(REM)":[3],"program":[4],"is":[5,104,159],"a":[6,27,60,99],"demand":[7,118],"response":[8],"(DR)":[9],"tool":[10],"that":[11],"automatically":[12],"manages":[13],"consumption":[15,24],"of":[16,26,41,85,110,126,132,141,149,154],"controllable":[17],"household":[18],"appliances":[19,86],"to":[20,30,37,74,91,106,138,146,164,170],"improve":[21,38,107],"the":[22,65,81,88,92,96,111,121,151,165,182],"profile":[25],"house":[28],"according":[29],"electricity":[31],"price.":[32],"REM":[33,62,184],"intends":[34],"not":[35],"only":[36],"technical":[39,108],"aspects":[40],"distribution":[42,112,142],"systems":[43],"but":[44],"also":[45],"motivate":[46],"customers":[47,175],"for":[48,174],"active":[49],"participation":[50],"in":[51,179],"DR":[52],"programs.":[53],"In":[54,64,95],"this":[55,57,133],"regard,":[56],"paper":[58],"proposes":[59],"two-level":[61],"framework.":[63],"first":[66],"level,":[67,98],"each":[68,127],"customer":[69],"runs":[70],"an":[71],"optimization":[72,102,135],"problem":[73],"minimize":[75,139,147],"his":[76],"payment":[77,89,124],"cost":[78,90,125],"and":[79,87,145,162,176],"sends":[80],"desired":[82,123,152],"operation":[83],"scheduling":[84,153],"system":[93,113,143,177],"operator.":[94],"second":[97],"multiobjective":[100],"(MO)":[101],"framework":[103],"designed":[105],"characteristics":[109],"such":[114],"as":[115],"total":[116],"load":[117,144],"deviation,":[119],"given":[120],"least":[122],"customer.":[128],"The":[129,156],"objective":[130],"functions":[131],"MO":[134],"structure":[136],"are":[137],"deviation":[140],"costs":[148],"modifying":[150],"customers.":[155],"proposed":[157],"algorithm":[158],"mathematically":[160],"modeled":[161],"applied":[163],"IEEE":[166],"34-node":[167],"test":[168],"feeder":[169],"prove":[171],"its":[172],"advantages":[173],"operators":[178],"comparison":[180],"with":[181],"available":[183],"strategies.":[185]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":12},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":8},{"year":2018,"cited_by_count":12},{"year":2017,"cited_by_count":6}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
