{"id":"https://openalex.org/W2343995367","doi":"https://doi.org/10.1109/tsg.2015.2513743","title":"Use of Adaptive Thermal Storage System as Smart Load for Voltage Control and Demand Response","display_name":"Use of Adaptive Thermal Storage System as Smart Load for Voltage Control and Demand Response","publication_year":2016,"publication_date":"2016-01-14","ids":{"openalex":"https://openalex.org/W2343995367","doi":"https://doi.org/10.1109/tsg.2015.2513743","mag":"2343995367"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2015.2513743","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2015.2513743","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5065532171","display_name":"Xiao Luo","orcid":"https://orcid.org/0000-0001-9002-9947"},"institutions":[{"id":"https://openalex.org/I889458895","display_name":"University of Hong Kong","ror":"https://ror.org/02zhqgq86","country_code":"HK","type":"education","lineage":["https://openalex.org/I889458895"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Xiao Luo","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong","institution_ids":["https://openalex.org/I889458895"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5020181160","display_name":"Chi-Kwan Lee","orcid":"https://orcid.org/0000-0002-0160-5808"},"institutions":[{"id":"https://openalex.org/I889458895","display_name":"University of Hong Kong","ror":"https://ror.org/02zhqgq86","country_code":"HK","type":"education","lineage":["https://openalex.org/I889458895"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Chi Kwan Lee","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong","institution_ids":["https://openalex.org/I889458895"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044633695","display_name":"Wai Man Ng","orcid":"https://orcid.org/0000-0003-4703-4278"},"institutions":[{"id":"https://openalex.org/I889458895","display_name":"University of Hong Kong","ror":"https://ror.org/02zhqgq86","country_code":"HK","type":"education","lineage":["https://openalex.org/I889458895"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Wai Man Ng","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong","institution_ids":["https://openalex.org/I889458895"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045614770","display_name":"Shuo Yan","orcid":"https://orcid.org/0000-0003-0413-7007"},"institutions":[{"id":"https://openalex.org/I889458895","display_name":"University of Hong Kong","ror":"https://ror.org/02zhqgq86","country_code":"HK","type":"education","lineage":["https://openalex.org/I889458895"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Shuo Yan","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong","institution_ids":["https://openalex.org/I889458895"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065433851","display_name":"Balarko Chaudhuri","orcid":"https://orcid.org/0000-0003-3747-7534"},"institutions":[{"id":"https://openalex.org/I47508984","display_name":"Imperial College London","ror":"https://ror.org/041kmwe10","country_code":"GB","type":"education","lineage":["https://openalex.org/I47508984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Balarko Chaudhuri","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, Imperial College London, London, U.K"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, Imperial College London, London, U.K","institution_ids":["https://openalex.org/I47508984"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5042360095","display_name":"S.Y.R. Hui","orcid":"https://orcid.org/0000-0002-5992-6559"},"institutions":[{"id":"https://openalex.org/I47508984","display_name":"Imperial College London","ror":"https://ror.org/041kmwe10","country_code":"GB","type":"education","lineage":["https://openalex.org/I47508984"]},{"id":"https://openalex.org/I889458895","display_name":"University of Hong Kong","ror":"https://ror.org/02zhqgq86","country_code":"HK","type":"education","lineage":["https://openalex.org/I889458895"]}],"countries":["GB","HK"],"is_corresponding":false,"raw_author_name":"Shu Yuen Ron Hui","raw_affiliation_strings":["Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong","Imperial College London, London, U.K"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong","institution_ids":["https://openalex.org/I889458895"]},{"raw_affiliation_string":"Imperial College London, London, U.K","institution_ids":["https://openalex.org/I47508984"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.2767,"has_fulltext":false,"cited_by_count":57,"citation_normalized_percentile":{"value":0.94583796,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"8","issue":"3","first_page":"1231","last_page":"1241"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9958000183105469,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9919000267982483,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5760005712509155},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.5728144645690918},{"id":"https://openalex.org/keywords/peaking-power-plant","display_name":"Peaking power plant","score":0.5077697038650513},{"id":"https://openalex.org/keywords/energy-storage","display_name":"Energy storage","score":0.5074238181114197},{"id":"https://openalex.org/keywords/thermal-energy-storage","display_name":"Thermal energy storage","score":0.48103028535842896},{"id":"https://openalex.org/keywords/base-load-power-plant","display_name":"Base load power plant","score":0.4631945490837097},{"id":"https://openalex.org/keywords/load-balancing","display_name":"Load balancing (electrical power)","score":0.45760369300842285},{"id":"https://openalex.org/keywords/automotive-engineering","display_name":"Automotive engineering","score":0.4553731679916382},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.44808071851730347},{"id":"https://openalex.org/keywords/dynamic-demand","display_name":"Dynamic demand","score":0.44147029519081116},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.43313270807266235},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4312693178653717},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.417472779750824},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4113119840621948},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.40965917706489563},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.37573421001434326},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.36166632175445557},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.2653772830963135},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.2569867670536041},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.17615780234336853}],"concepts":[{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5760005712509155},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.5728144645690918},{"id":"https://openalex.org/C154594046","wikidata":"https://www.wikidata.org/wiki/Q18979989","display_name":"Peaking power plant","level":4,"score":0.5077697038650513},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.5074238181114197},{"id":"https://openalex.org/C183287310","wikidata":"https://www.wikidata.org/wiki/Q2142963","display_name":"Thermal energy storage","level":2,"score":0.48103028535842896},{"id":"https://openalex.org/C123153844","wikidata":"https://www.wikidata.org/wiki/Q360897","display_name":"Base load power plant","level":4,"score":0.4631945490837097},{"id":"https://openalex.org/C138959212","wikidata":"https://www.wikidata.org/wiki/Q1806783","display_name":"Load balancing (electrical power)","level":3,"score":0.45760369300842285},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4553731679916382},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.44808071851730347},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.44147029519081116},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.43313270807266235},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4312693178653717},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.417472779750824},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4113119840621948},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.40965917706489563},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37573421001434326},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.36166632175445557},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.2653772830963135},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.2569867670536041},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.17615780234336853},{"id":"https://openalex.org/C15744967","wikidata":"https://www.wikidata.org/wiki/Q9418","display_name":"Psychology","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C18903297","wikidata":"https://www.wikidata.org/wiki/Q7150","display_name":"Ecology","level":1,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C11171543","wikidata":"https://www.wikidata.org/wiki/Q41630","display_name":"Psychoanalysis","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tsg.2015.2513743","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2015.2513743","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:hub.hku.hk:10722/247392","is_oa":false,"landing_page_url":"http://hdl.handle.net/10722/247392","pdf_url":null,"source":{"id":"https://openalex.org/S4377196271","display_name":"The HKU Scholars Hub (University of Hong Kong)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I889458895","host_organization_name":"University of Hong Kong","host_organization_lineage":["https://openalex.org/I889458895"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Article"},{"id":"pmh:oai:spiral.imperial.ac.uk:10044/1/34682","is_oa":false,"landing_page_url":"http://hdl.handle.net/10044/1/34682","pdf_url":null,"source":{"id":"https://openalex.org/S4306401396","display_name":"Spiral (Imperial College London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I47508984","host_organization_name":"Imperial College London","host_organization_lineage":["https://openalex.org/I47508984"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"1241","raw_type":"Journal Article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8899999856948853,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G4288122205","display_name":"Integrated Operation and Planning for Smart Electric Distribution Networks (OPEN)","funder_award_id":"EP/K006274/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G6513674592","display_name":null,"funder_award_id":"EP/K006274/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"}],"funders":[{"id":"https://openalex.org/F4320334627","display_name":"Engineering and Physical Sciences Research Council","ror":"https://ror.org/0439y7842"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1967688701","https://openalex.org/W1978836830","https://openalex.org/W2005585337","https://openalex.org/W2012192910","https://openalex.org/W2022935688","https://openalex.org/W2024314554","https://openalex.org/W2027037246","https://openalex.org/W2031187448","https://openalex.org/W2036573293","https://openalex.org/W2037573409","https://openalex.org/W2040964155","https://openalex.org/W2049194150","https://openalex.org/W2092050925","https://openalex.org/W2120411297","https://openalex.org/W2135000777","https://openalex.org/W2144456054","https://openalex.org/W2536359511","https://openalex.org/W2541592390","https://openalex.org/W6656694211"],"related_works":["https://openalex.org/W1986909959","https://openalex.org/W92211312","https://openalex.org/W4387415905","https://openalex.org/W2385272050","https://openalex.org/W68763171","https://openalex.org/W4226407635","https://openalex.org/W3126575123","https://openalex.org/W2353074559","https://openalex.org/W4304091547","https://openalex.org/W3159717474"],"abstract_inverted_index":{"This":[0],"paper":[1],"describes":[2],"how":[3],"a":[4,12,41,50,88,93],"large-scale":[5,94],"ice-thermal":[6,95,126],"storage":[7,96,127],"can":[8,67],"be":[9],"turned":[10],"into":[11],"smart":[13],"load":[14,35,44,66],"for":[15,80],"fast":[16],"voltage":[17,133],"control":[18],"and":[19,76,115,134],"demand-side":[20],"management":[21],"in":[22,49,71,128,131,137],"power":[23,53,69,78,82,117,139],"systems":[24],"with":[25],"intermittent":[26],"renewable":[27],"power,":[28],"while":[29,73],"maintaining":[30],"its":[31],"existing":[32],"function":[33],"of":[34,39,59,111,124],"shaving.":[36],"The":[37,119],"possibility":[38],"modifying":[40],"conventional":[42],"thermal":[43,65],"has":[45,98],"been":[46,99],"practically":[47],"demonstrated":[48],"refrigerator":[51],"using":[52,108,125],"electronics":[54],"technology.":[55],"With":[56],"the":[57,63,81,104,122],"help":[58],"an":[60],"electric":[61],"spring,":[62],"modified":[64],"reduce":[68],"imbalance":[70],"buildings":[72,130],"providing":[74],"active":[75],"reactive":[77],"compensation":[79],"grid.":[83],"Based":[84],"on":[85],"practical":[86],"data,":[87],"building":[89],"energy":[90],"model":[91],"incorporating":[92],"system":[97],"successfully":[100],"used":[101],"to":[102],"demonstrate":[103],"advantageous":[105],"demand-response":[106],"features":[107],"computer":[109],"simulation":[110],"both":[112],"grid":[113],"connected":[114],"isolated":[116],"systems.":[118],"results":[120],"indicate":[121],"potential":[123],"tall":[129],"reducing":[132],"frequency":[135],"fluctuations":[136],"weak":[138],"grids.":[140]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":10},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":10},{"year":2018,"cited_by_count":9},{"year":2017,"cited_by_count":3},{"year":2016,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2016-06-24T00:00:00"}