{"id":"https://openalex.org/W2013413443","doi":"https://doi.org/10.1109/tsg.2015.2399497","title":"A Multiobjective Approach to Multimicrogrid System Design","display_name":"A Multiobjective Approach to Multimicrogrid System Design","publication_year":2015,"publication_date":"2015-02-26","ids":{"openalex":"https://openalex.org/W2013413443","doi":"https://doi.org/10.1109/tsg.2015.2399497","mag":"2013413443"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2015.2399497","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2015.2399497","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["arxiv","crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/1705.02123","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Wei-Yu Chiu","orcid":null},"institutions":[{"id":"https://openalex.org/I99908691","display_name":"Yuan Ze University","ror":"https://ror.org/01fv1ds98","country_code":"TW","type":"education","lineage":["https://openalex.org/I99908691"]}],"countries":["TW"],"is_corresponding":true,"raw_author_name":"Wei-Yu Chiu","raw_affiliation_strings":["Department of Electrical Engineering and with the Innovation Center for Big Data and Digital Convergence, Yuan Ze University, Taoyuan, Taiwan"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering and with the Innovation Center for Big Data and Digital Convergence, Yuan Ze University, Taoyuan, Taiwan","institution_ids":["https://openalex.org/I99908691"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Hongjian Sun","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hongjian Sun","raw_affiliation_strings":["School of Engineering and Computing Science, Durham University, Durham, U.K"],"affiliations":[{"raw_affiliation_string":"School of Engineering and Computing Science, Durham University, Durham, U.K","institution_ids":[]}]},{"author_position":"last","author":{"id":null,"display_name":"H. Vincent Poor","orcid":null},"institutions":[{"id":"https://openalex.org/I20089843","display_name":"Princeton University","ror":"https://ror.org/00hx57361","country_code":"US","type":"education","lineage":["https://openalex.org/I20089843"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"H. Vincent Poor","raw_affiliation_strings":["Department of Electrical Engineering, Princeton University, Princeton, NJ, USA"],"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Princeton University, Princeton, NJ, USA","institution_ids":["https://openalex.org/I20089843"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I99908691"],"apc_list":null,"apc_paid":null,"fwci":14.6429,"has_fulltext":false,"cited_by_count":118,"citation_normalized_percentile":{"value":0.99126631,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":100},"biblio":{"volume":"6","issue":"5","first_page":"2263","last_page":"2272"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.7346000075340271,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.7346000075340271,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.1648000031709671,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.026799999177455902,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5938000082969666},{"id":"https://openalex.org/keywords/pareto-principle","display_name":"Pareto principle","score":0.5608000159263611},{"id":"https://openalex.org/keywords/renewable-energy","display_name":"Renewable energy","score":0.5138999819755554},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"Distributed generation","score":0.45590001344680786},{"id":"https://openalex.org/keywords/operator","display_name":"Operator (biology)","score":0.45410001277923584},{"id":"https://openalex.org/keywords/multi-objective-optimization","display_name":"Multi-objective optimization","score":0.4334999918937683},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.4131999909877777},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4056999981403351},{"id":"https://openalex.org/keywords/scheme","display_name":"Scheme (mathematics)","score":0.36070001125335693},{"id":"https://openalex.org/keywords/network-planning-and-design","display_name":"Network planning and design","score":0.3594000041484833}],"concepts":[{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.6180999875068665},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5938000082969666},{"id":"https://openalex.org/C137635306","wikidata":"https://www.wikidata.org/wiki/Q182667","display_name":"Pareto principle","level":2,"score":0.5608000159263611},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5232999920845032},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5138999819755554},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.45590001344680786},{"id":"https://openalex.org/C17020691","wikidata":"https://www.wikidata.org/wiki/Q139677","display_name":"Operator (biology)","level":5,"score":0.45410001277923584},{"id":"https://openalex.org/C68781425","wikidata":"https://www.wikidata.org/wiki/Q2052203","display_name":"Multi-objective optimization","level":2,"score":0.4334999918937683},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.4131999909877777},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4056999981403351},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.36070001125335693},{"id":"https://openalex.org/C114563136","wikidata":"https://www.wikidata.org/wiki/Q19725982","display_name":"Network planning and design","level":2,"score":0.3594000041484833},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3458999991416931},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.329800009727478},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.31769999861717224},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.3163999915122986},{"id":"https://openalex.org/C2986314615","wikidata":"https://www.wikidata.org/wiki/Q36829","display_name":"Pareto optimal","level":3,"score":0.3122999966144562},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.3093999922275543},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.30889999866485596},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.30880001187324524},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3034000098705292},{"id":"https://openalex.org/C186394612","wikidata":"https://www.wikidata.org/wiki/Q7098942","display_name":"Optimal design","level":2,"score":0.3028999865055084},{"id":"https://openalex.org/C31352089","wikidata":"https://www.wikidata.org/wiki/Q3750474","display_name":"Systems design","level":2,"score":0.3003999888896942},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.3003000020980835},{"id":"https://openalex.org/C118127601","wikidata":"https://www.wikidata.org/wiki/Q3797610","display_name":"Pareto analysis","level":3,"score":0.2930000126361847},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.2874999940395355},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.28119999170303345},{"id":"https://openalex.org/C2776849302","wikidata":"https://www.wikidata.org/wiki/Q1239166","display_name":"Energy market","level":3,"score":0.27309998869895935},{"id":"https://openalex.org/C2989126829","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Power network","level":4,"score":0.2712000012397766},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.2694999873638153},{"id":"https://openalex.org/C146733006","wikidata":"https://www.wikidata.org/wiki/Q676081","display_name":"Electricity market","level":3,"score":0.2621000111103058},{"id":"https://openalex.org/C2777693866","wikidata":"https://www.wikidata.org/wiki/Q359099","display_name":"Blackout","level":4,"score":0.2590999901294708}],"mesh":[],"locations_count":4,"locations":[{"id":"doi:10.1109/tsg.2015.2399497","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2015.2399497","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:dro.dur.ac.uk.OAI2:14825","is_oa":false,"landing_page_url":"http://dro.dur.ac.uk/14825/","pdf_url":null,"source":{"id":"https://openalex.org/S4377196258","display_name":"Durham Research Online (Durham University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I190082696","host_organization_name":"Durham University","host_organization_lineage":["https://openalex.org/I190082696"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"IEEE transactions on smart grid, 2015, Vol.6(5), pp.2263-2272 [Peer Reviewed Journal]","raw_type":"Article"},{"id":"pmh:oai:arXiv.org:1705.02123","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1705.02123","pdf_url":"https://arxiv.org/pdf/1705.02123","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},{"id":"pmh:oai:durham-repository.worktribe.com:1412406","is_oa":true,"landing_page_url":"https://durham-repository.worktribe.com/output/1412406","pdf_url":null,"source":{"id":"https://openalex.org/S4306400188","display_name":"Durham Research Online (Durham University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I190082696","host_organization_name":"Durham University","host_organization_lineage":["https://openalex.org/I190082696"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Journal Article"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:1705.02123","is_oa":true,"landing_page_url":"http://arxiv.org/abs/1705.02123","pdf_url":"https://arxiv.org/pdf/1705.02123","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":41,"referenced_works":["https://openalex.org/W1551852446","https://openalex.org/W1967370750","https://openalex.org/W1972262259","https://openalex.org/W1978891258","https://openalex.org/W1981657074","https://openalex.org/W1983471712","https://openalex.org/W1983820316","https://openalex.org/W1989649628","https://openalex.org/W1997188340","https://openalex.org/W1999126112","https://openalex.org/W2000535949","https://openalex.org/W2008496286","https://openalex.org/W2010133122","https://openalex.org/W2011587419","https://openalex.org/W2029623232","https://openalex.org/W2034330069","https://openalex.org/W2034441946","https://openalex.org/W2039007401","https://openalex.org/W2042170486","https://openalex.org/W2042864172","https://openalex.org/W2050342886","https://openalex.org/W2050495423","https://openalex.org/W2058192020","https://openalex.org/W2060458208","https://openalex.org/W2065686820","https://openalex.org/W2066937816","https://openalex.org/W2068060907","https://openalex.org/W2095244591","https://openalex.org/W2132011253","https://openalex.org/W2136870181","https://openalex.org/W2140988255","https://openalex.org/W2141557169","https://openalex.org/W2142784486","https://openalex.org/W2146573675","https://openalex.org/W2153339991","https://openalex.org/W2166130125","https://openalex.org/W4253678958","https://openalex.org/W4292408320","https://openalex.org/W6607099363","https://openalex.org/W6639464859","https://openalex.org/W6644877316"],"related_works":[],"abstract_inverted_index":{"The":[0,117],"main":[1],"goal":[2],"of":[3,22,26,138],"this":[4],"paper":[5],"is":[6,30,69,115],"to":[7,59,71,100,103,164],"design":[8,33],"a":[9,14,20,31,46,66,112,134,139,148],"market":[10],"operator":[11,17],"(MO)":[12],"and":[13,34,124],"distribution":[15],"network":[16,21,61,105],"(DNO)":[18],"for":[19,83],"microgrids":[23,37,92],"in":[24,49],"consideration":[25],"multiple":[27],"objectives.":[28],"This":[29],"high-level":[32],"only":[35],"those":[36],"with":[38],"nondispatchable":[39],"renewable":[40],"energy":[41,89],"sources":[42],"are":[43,130,162],"considered.":[44],"For":[45,65],"power":[47,58,125],"grid":[48],"the":[50,52,60,73,79,122,128,145,166],"network,":[51],"net":[53,74],"value":[54],"derived":[55,76],"from":[56,77],"providing":[57],"must":[62,93],"be":[63,94,159],"maximized.":[64],"microgrid,":[67],"it":[68],"desirable":[70],"maximize":[72],"gain":[75],"consuming":[78],"received":[80],"power.":[81],"Finally,":[82],"an":[84],"independent":[85],"system":[86],"operator,":[87],"stored":[88],"levels":[90],"at":[91],"maintained":[95],"as":[96,98],"close":[97],"possible":[99],"storage":[101],"capacity":[102],"secure":[104],"emergency":[106],"operation.":[107],"To":[108],"achieve":[109],"these":[110],"objectives,":[111],"multiobjective":[113,140],"approach":[114],"proposed.":[116],"price":[118],"signal":[119],"generated":[120],"by":[121,127],"MO":[123],"distributed":[126],"DNO":[129],"assigned":[131],"based":[132],"on":[133],"Pareto":[135],"optimal":[136],"solution":[137],"optimization":[141],"problem.":[142],"By":[143],"using":[144],"proposed":[146,167],"approach,":[147],"fair":[149],"scheme":[150],"that":[151],"does":[152],"not":[153],"advantage":[154],"one":[155],"particular":[156],"objective":[157],"can":[158],"attained.":[160],"Simulations":[161],"provided":[163],"validate":[165],"methodology.":[168]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":13},{"year":2022,"cited_by_count":9},{"year":2021,"cited_by_count":14},{"year":2020,"cited_by_count":15},{"year":2019,"cited_by_count":16},{"year":2018,"cited_by_count":13},{"year":2017,"cited_by_count":17},{"year":2016,"cited_by_count":12},{"year":2015,"cited_by_count":1}],"updated_date":"2026-04-04T16:13:02.066488","created_date":"2016-06-24T00:00:00"}
