{"id":"https://openalex.org/W1993036147","doi":"https://doi.org/10.1109/tsg.2014.2302476","title":"A Coordinated Multi-Switch Attack for Cascading Failures in Smart Grid","display_name":"A Coordinated Multi-Switch Attack for Cascading Failures in Smart Grid","publication_year":2014,"publication_date":"2014-04-11","ids":{"openalex":"https://openalex.org/W1993036147","doi":"https://doi.org/10.1109/tsg.2014.2302476","mag":"1993036147"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2014.2302476","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2014.2302476","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100449812","display_name":"Shan Liu","orcid":"https://orcid.org/0000-0003-3399-7081"},"institutions":[{"id":"https://openalex.org/I75689368","display_name":"Communication University of China","ror":"https://ror.org/04facbs33","country_code":"CN","type":"education","lineage":["https://openalex.org/I75689368"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shan Liu","raw_affiliation_strings":["Department of Network Engineering, Communication University of China, Beijing, China","[Department of Network Engineering, Communication University of China, Beijing, China]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Network Engineering, Communication University of China, Beijing, China","institution_ids":["https://openalex.org/I75689368"]},{"raw_affiliation_string":"[Department of Network Engineering, Communication University of China, Beijing, China]","institution_ids":["https://openalex.org/I75689368"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100427435","display_name":"Bo Chen","orcid":"https://orcid.org/0000-0003-4145-0676"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Bo Chen","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, United States","Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, United States","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5085825043","display_name":"Takis Zourntos","orcid":null},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Takis Zourntos","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, United States","Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, United States","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077035168","display_name":"Deepa Kundur","orcid":"https://orcid.org/0000-0001-5999-1847"},"institutions":[{"id":"https://openalex.org/I185261750","display_name":"University of Toronto","ror":"https://ror.org/03dbr7087","country_code":"CA","type":"education","lineage":["https://openalex.org/I185261750"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Deepa Kundur","raw_affiliation_strings":["Department of Electrical and Computer Engineering, University of Toronto, Toronto, Ontario, Canada","Dept. of Electr. & Comput. Eng., Univ. of Toronto, Toronto, ON, Canada#TAB#"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, University of Toronto, Toronto, Ontario, Canada","institution_ids":["https://openalex.org/I185261750"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng., Univ. of Toronto, Toronto, ON, Canada#TAB#","institution_ids":["https://openalex.org/I185261750"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048501979","display_name":"Karen L. Butler-Purry","orcid":"https://orcid.org/0000-0001-6835-7960"},"institutions":[{"id":"https://openalex.org/I91045830","display_name":"Texas A&M University","ror":"https://ror.org/01f5ytq51","country_code":"US","type":"education","lineage":["https://openalex.org/I91045830"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Karen Butler-Purry","raw_affiliation_strings":["Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, United States","Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas, United States","institution_ids":["https://openalex.org/I91045830"]},{"raw_affiliation_string":"Dept. of Electr. & Comput. Eng, Texas A&M Univ., College Station, TX, USA","institution_ids":["https://openalex.org/I91045830"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":13.7011,"has_fulltext":false,"cited_by_count":125,"citation_normalized_percentile":{"value":0.9887985,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":100},"biblio":{"volume":"5","issue":"3","first_page":"1183","last_page":"1195"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10400","display_name":"Network Security and Intrusion Detection","score":0.9732999801635742,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9603999853134155,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.8740767240524292},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.7189825773239136},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5539822578430176},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.529521644115448},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5181916356086731},{"id":"https://openalex.org/keywords/context","display_name":"Context (archaeology)","score":0.5170774459838867},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.5053754448890686},{"id":"https://openalex.org/keywords/adversary","display_name":"Adversary","score":0.48298707604408264},{"id":"https://openalex.org/keywords/computer-security","display_name":"Computer security","score":0.4597490131855011},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.4405127465724945},{"id":"https://openalex.org/keywords/cyber-attack","display_name":"Cyber-attack","score":0.42395728826522827},{"id":"https://openalex.org/keywords/generator","display_name":"Generator (circuit theory)","score":0.4199880361557007},{"id":"https://openalex.org/keywords/distributed-computing","display_name":"Distributed computing","score":0.41279250383377075},{"id":"https://openalex.org/keywords/computer-network","display_name":"Computer network","score":0.3510555326938629},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.27768009901046753},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.1874200999736786}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.8740767240524292},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.7189825773239136},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5539822578430176},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.529521644115448},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5181916356086731},{"id":"https://openalex.org/C2779343474","wikidata":"https://www.wikidata.org/wiki/Q3109175","display_name":"Context (archaeology)","level":2,"score":0.5170774459838867},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.5053754448890686},{"id":"https://openalex.org/C41065033","wikidata":"https://www.wikidata.org/wiki/Q2825412","display_name":"Adversary","level":2,"score":0.48298707604408264},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.4597490131855011},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4405127465724945},{"id":"https://openalex.org/C201307755","wikidata":"https://www.wikidata.org/wiki/Q4071928","display_name":"Cyber-attack","level":2,"score":0.42395728826522827},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.4199880361557007},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.41279250383377075},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3510555326938629},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.27768009901046753},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.1874200999736786},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2014.2302476","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2014.2302476","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:CiteSeerX.psu:10.1.1.717.564","is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.717.564","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://www.comm.utoronto.ca/%7Edkundur/pub_pdfs/LiuCheZouKunButTSG14.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/16","display_name":"Peace, Justice and strong institutions","score":0.8199999928474426}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1505779585","https://openalex.org/W1552094772","https://openalex.org/W1770527767","https://openalex.org/W1980576005","https://openalex.org/W2004421225","https://openalex.org/W2005028112","https://openalex.org/W2022144424","https://openalex.org/W2027688150","https://openalex.org/W2038651258","https://openalex.org/W2042615200","https://openalex.org/W2051054517","https://openalex.org/W2059950755","https://openalex.org/W2116051862","https://openalex.org/W2128027818","https://openalex.org/W2129035245","https://openalex.org/W2152624017","https://openalex.org/W2246905723","https://openalex.org/W6661173792"],"related_works":["https://openalex.org/W2135621634","https://openalex.org/W2946248804","https://openalex.org/W4308217825","https://openalex.org/W2120190783","https://openalex.org/W2365076629","https://openalex.org/W2163879918","https://openalex.org/W2900584019","https://openalex.org/W3110049015","https://openalex.org/W3204945059","https://openalex.org/W2032188264"],"abstract_inverted_index":{"This":[0],"paper":[1],"explores":[2],"distributed":[3,85],"smart":[4],"grid":[5],"attack":[6,55],"strategies":[7,87],"to":[8,23,41,54,71],"destabilize":[9,42],"power":[10,31],"system":[11,16],"components":[12],"using":[13],"variable":[14],"structure":[15],"theory.":[17],"Here,":[18],"an":[19],"opponent":[20],"is":[21],"able":[22],"remotely":[24],"control":[25],"multiple":[26],"circuit":[27],"breakers":[28],"within":[29],"a":[30,57,79],"system,":[32],"say":[33],"through":[34,46],"data":[35],"corruption":[36],"or":[37],"communication":[38],"network":[39],"attack,":[40],"target":[43],"synchronous":[44],"generators":[45],"application":[47],"of":[48,66],"state-dependent":[49],"breaker":[50],"switching.":[51],"In":[52],"contrast":[53],"via":[56],"single":[58],"breaker,":[59],"the":[60,93],"multi-switch":[61,86],"case":[62],"provides":[63],"additional":[64],"degrees":[65],"freedom":[67],"that":[68],"can":[69],"lead":[70],"stealthier":[72],"and":[73,88],"wide-scale":[74],"cascading":[75],"failures.":[76],"We":[77],"provide":[78],"dynamical":[80],"systems":[81],"context":[82],"for":[83],"formulating":[84],"execute":[89],"such":[90],"attacks":[91],"on":[92],"New":[94],"England":[95],"10-generator":[96],"39-bus":[97],"test":[98],"system.":[99]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":11},{"year":2023,"cited_by_count":10},{"year":2022,"cited_by_count":17},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":15},{"year":2019,"cited_by_count":10},{"year":2018,"cited_by_count":15},{"year":2017,"cited_by_count":14},{"year":2016,"cited_by_count":10},{"year":2015,"cited_by_count":9},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
