{"id":"https://openalex.org/W2035640651","doi":"https://doi.org/10.1109/tsg.2013.2295540","title":"The Impact of Uncertain Physical Parameters on HVAC Demand Response","display_name":"The Impact of Uncertain Physical Parameters on HVAC Demand Response","publication_year":2014,"publication_date":"2014-02-04","ids":{"openalex":"https://openalex.org/W2035640651","doi":"https://doi.org/10.1109/tsg.2013.2295540","mag":"2035640651"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2013.2295540","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2013.2295540","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5109081636","display_name":"Yannan Sun","orcid":null},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yannan Sun","raw_affiliation_strings":["Pacific Northwest National Laboratory, Richland, WA, USA","Northwest Nat. Lab., Richland, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest National Laboratory, Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]},{"raw_affiliation_string":"Northwest Nat. Lab., Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5085217555","display_name":"Marcelo Elizondo","orcid":"https://orcid.org/0000-0002-6621-252X"},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Marcelo Elizondo","raw_affiliation_strings":["Pacific Northwest National Laboratory, Richland, WA, USA","Northwest Nat. Lab., Richland, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest National Laboratory, Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]},{"raw_affiliation_string":"Northwest Nat. Lab., Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086816369","display_name":"Shuai Lu","orcid":"https://orcid.org/0000-0002-5753-5327"},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Shuai Lu","raw_affiliation_strings":["Pacific Northwest National Laboratory, Richland, WA, USA","Northwest Nat. Lab., Richland, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest National Laboratory, Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]},{"raw_affiliation_string":"Northwest Nat. Lab., Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5050210222","display_name":"Jason Fuller","orcid":"https://orcid.org/0000-0002-0462-0093"},"institutions":[{"id":"https://openalex.org/I142606810","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307","country_code":"US","type":"facility","lineage":["https://openalex.org/I1325736334","https://openalex.org/I1330989302","https://openalex.org/I142606810","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Jason C. Fuller","raw_affiliation_strings":["Pacific Northwest National Laboratory, Richland, WA, USA","Northwest Nat. Lab., Richland, WA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Pacific Northwest National Laboratory, Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]},{"raw_affiliation_string":"Northwest Nat. Lab., Richland, WA, USA","institution_ids":["https://openalex.org/I142606810"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I142606810"],"apc_list":null,"apc_paid":null,"fwci":2.4863,"has_fulltext":false,"cited_by_count":43,"citation_normalized_percentile":{"value":0.902805,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"5","issue":"2","first_page":"916","last_page":"923"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.9789999723434448,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvac","display_name":"HVAC","score":0.9376269578933716},{"id":"https://openalex.org/keywords/demand-response","display_name":"Demand response","score":0.695921003818512},{"id":"https://openalex.org/keywords/population","display_name":"Population","score":0.5271862745285034},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.440559983253479},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"Air conditioning","score":0.426928848028183},{"id":"https://openalex.org/keywords/monte-carlo-method","display_name":"Monte Carlo method","score":0.42198723554611206},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.411196768283844},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.39958328008651733},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.23209354281425476},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.13190549612045288},{"id":"https://openalex.org/keywords/electricity","display_name":"Electricity","score":0.12746748328208923},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.09679192304611206}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9376269578933716},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.695921003818512},{"id":"https://openalex.org/C2908647359","wikidata":"https://www.wikidata.org/wiki/Q2625603","display_name":"Population","level":2,"score":0.5271862745285034},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.440559983253479},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.426928848028183},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.42198723554611206},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.411196768283844},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.39958328008651733},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.23209354281425476},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.13190549612045288},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.12746748328208923},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.09679192304611206},{"id":"https://openalex.org/C144024400","wikidata":"https://www.wikidata.org/wiki/Q21201","display_name":"Sociology","level":0,"score":0.0},{"id":"https://openalex.org/C149923435","wikidata":"https://www.wikidata.org/wiki/Q37732","display_name":"Demography","level":1,"score":0.0},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2013.2295540","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2013.2295540","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.44999998807907104,"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320332681","display_name":"Binghamton University","ror":"https://ror.org/008rmbt77"},{"id":"https://openalex.org/F4320338354","display_name":"Pacific Northwest National Laboratory","ror":"https://ror.org/05h992307"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":13,"referenced_works":["https://openalex.org/W1541786028","https://openalex.org/W1999913837","https://openalex.org/W2005617509","https://openalex.org/W2076335823","https://openalex.org/W2091510875","https://openalex.org/W2117320576","https://openalex.org/W2134720410","https://openalex.org/W2148406707","https://openalex.org/W2156601564","https://openalex.org/W2160393298","https://openalex.org/W4236874811","https://openalex.org/W4252199359","https://openalex.org/W6673637559"],"related_works":["https://openalex.org/W2112866972","https://openalex.org/W2900606913","https://openalex.org/W4320003279","https://openalex.org/W2326910963","https://openalex.org/W3046823714","https://openalex.org/W1997024178","https://openalex.org/W2348218441","https://openalex.org/W4205684936","https://openalex.org/W3021806226","https://openalex.org/W2771815161"],"abstract_inverted_index":{"Heating,":[0],"ventilation":[1],"and":[2,41,53,113,154,173,191],"air":[3],"conditioning":[4],"(HVAC)":[5],"units":[6,28,65],"are":[7,117,136],"one":[8],"of":[9,27,48,61,64,77,101,107,131,146,180,218],"the":[10,46,58,75,88,99,105,111,127,139,144,151,178,181,185,188,201,216],"major":[11],"resources":[12],"providing":[13],"demand":[14],"response":[15,60,145],"(DR)":[16],"in":[17,110,133,187,215],"residential":[18],"buildings.":[19],"A":[20],"DR":[21,67,81,89,161,182,207,224],"program":[22],"requires":[23],"a":[24,31,62,71,159,165],"large":[25],"population":[26,63,149],"to":[29,66,74,86,120,176,184,200,220],"make":[30],"significant":[32],"impact":[33,130,199],"on":[34,197],"power":[35],"grid":[36],"services":[37],"like":[38],"peak":[39],"shaving":[40],"balancing.":[42],"This":[43,69],"paper":[44],"investigates":[45],"importance":[47],"various":[49],"HVAC":[50,78,95,148,203],"physical":[51],"parameters":[52,97,116,195],"their":[54,198],"distributions":[55,125,135],"that":[56],"affect":[57],"aggregate":[59,202],"signals.":[68],"is":[70],"key":[72],"step":[73],"construction":[76],"models":[79],"with":[80,170],"functionality,":[82],"given":[83,160],"insufficient":[84],"data,":[85],"predict":[87],"capacity":[90],"available":[91],"for":[92,158],"dispatch.":[93],"The":[94,129],"model":[96],"include":[98],"size":[100],"floors,":[102],"insulation":[103],"efficiency,":[104],"amount":[106],"solid":[108],"mass":[109],"house,":[112],"efficiency.":[114],"These":[115],"usually":[118],"assumed":[119],"follow":[121],"Gaussian":[122],"or":[123,206],"Uniform":[124],"over":[126],"population.":[128],"uncertainty":[132,186],"parameter":[134,189],"quantified":[137],"through":[138],"following":[140],"steps:":[141],"1)":[142],"Simulate":[143],"an":[147,222],"during":[150,155],"transient":[152],"phase":[153],"steady":[156],"state":[157],"signal;":[162],"2)":[163],"Use":[164],"quasi-Monte":[166],"Carlo":[167],"sampling":[168],"method":[169],"linear":[171],"regression":[172],"Prony":[174],"analysis":[175,212],"evaluate":[177],"sensitivity":[179],"output":[183],"distributions;":[190],"3)":[192],"Identify":[193],"important":[194],"based":[196],"response.":[204],"Utilities":[205],"providers":[208],"can":[209],"use":[210],"this":[211],"as":[213],"guidance":[214],"collection":[217],"data":[219],"derive":[221],"effective":[223],"model.":[225]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":4},{"year":2016,"cited_by_count":5},{"year":2015,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
