{"id":"https://openalex.org/W1991630164","doi":"https://doi.org/10.1109/tsg.2012.2208127","title":"Current-Only Directional Overcurrent Protection for Distribution Automation: Challenges and Solutions","display_name":"Current-Only Directional Overcurrent Protection for Distribution Automation: Challenges and Solutions","publication_year":2012,"publication_date":"2012-08-22","ids":{"openalex":"https://openalex.org/W1991630164","doi":"https://doi.org/10.1109/tsg.2012.2208127","mag":"1991630164"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2012.2208127","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2012.2208127","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5086713046","display_name":"Abhisek Ukil","orcid":"https://orcid.org/0000-0003-3100-7865"},"institutions":[{"id":"https://openalex.org/I885143765","display_name":"ABB (Switzerland)","ror":"https://ror.org/00ks5vt51","country_code":"CH","type":"company","lineage":["https://openalex.org/I885143765"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Abhisek Ukil","raw_affiliation_strings":["ABB Corporate Research, Dattwil-Baden, Switzerland","ABB Corp. Res., Baden-Daettwil, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ABB Corporate Research, Dattwil-Baden, Switzerland","institution_ids":["https://openalex.org/I885143765"]},{"raw_affiliation_string":"ABB Corp. Res., Baden-Daettwil, Switzerland","institution_ids":["https://openalex.org/I885143765"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046060985","display_name":"Bernhard Deck","orcid":null},"institutions":[{"id":"https://openalex.org/I885143765","display_name":"ABB (Switzerland)","ror":"https://ror.org/00ks5vt51","country_code":"CH","type":"company","lineage":["https://openalex.org/I885143765"]}],"countries":["CH"],"is_corresponding":false,"raw_author_name":"Bernhard Deck","raw_affiliation_strings":["ABB S\u00e9cheron S. A., Baden, Switzerland","ABB Secheron S.A., Baden, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ABB S\u00e9cheron S. A., Baden, Switzerland","institution_ids":["https://openalex.org/I885143765"]},{"raw_affiliation_string":"ABB Secheron S.A., Baden, Switzerland","institution_ids":["https://openalex.org/I885143765"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073913706","display_name":"Vishal H Shah","orcid":"https://orcid.org/0000-0001-6282-1988"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Vishal H Shah","raw_affiliation_strings":["ABB GISL, Vadodara, India","ABB GISL Corp. Res. Center, Vadodara, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"ABB GISL, Vadodara, India","institution_ids":[]},{"raw_affiliation_string":"ABB GISL Corp. Res. Center, Vadodara, India","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":8.4214,"has_fulltext":false,"cited_by_count":81,"citation_normalized_percentile":{"value":0.97281833,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":91,"max":99},"biblio":{"volume":"3","issue":"4","first_page":"1687","last_page":"1694"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9993000030517578,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/overcurrent","display_name":"Overcurrent","score":0.9317529201507568},{"id":"https://openalex.org/keywords/relay","display_name":"Relay","score":0.7351543307304382},{"id":"https://openalex.org/keywords/protective-relay","display_name":"Protective relay","score":0.6628928184509277},{"id":"https://openalex.org/keywords/digital-protective-relay","display_name":"Digital protective relay","score":0.5599384903907776},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.5451655983924866},{"id":"https://openalex.org/keywords/circuit-breaker","display_name":"Circuit breaker","score":0.5352725386619568},{"id":"https://openalex.org/keywords/grid","display_name":"Grid","score":0.5249353051185608},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.5212672352790833},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.4943382740020752},{"id":"https://openalex.org/keywords/smart-grid","display_name":"Smart grid","score":0.48451703786849976},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"Power-system protection","score":0.478101909160614},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.47535011172294617},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4690437912940979},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.46160024404525757},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.45931413769721985},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.4296165704727173},{"id":"https://openalex.org/keywords/transmission","display_name":"Transmission (telecommunications)","score":0.41670486330986023},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.39555981755256653}],"concepts":[{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.9317529201507568},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.7351543307304382},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.6628928184509277},{"id":"https://openalex.org/C183912175","wikidata":"https://www.wikidata.org/wiki/Q4293157","display_name":"Digital protective relay","level":5,"score":0.5599384903907776},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5451655983924866},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.5352725386619568},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5249353051185608},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5212672352790833},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4943382740020752},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.48451703786849976},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.478101909160614},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.47535011172294617},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4690437912940979},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.46160024404525757},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45931413769721985},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.4296165704727173},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.41670486330986023},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.39555981755256653},{"id":"https://openalex.org/C2524010","wikidata":"https://www.wikidata.org/wiki/Q8087","display_name":"Geometry","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.0},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tsg.2012.2208127","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2012.2208127","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7699999809265137,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":22,"referenced_works":["https://openalex.org/W208605634","https://openalex.org/W1023701950","https://openalex.org/W1978285438","https://openalex.org/W2007167276","https://openalex.org/W2010252381","https://openalex.org/W2037580229","https://openalex.org/W2042270137","https://openalex.org/W2110711675","https://openalex.org/W2118966907","https://openalex.org/W2120323788","https://openalex.org/W2121813087","https://openalex.org/W2126621020","https://openalex.org/W2132350861","https://openalex.org/W2148123137","https://openalex.org/W2151761098","https://openalex.org/W2201250126","https://openalex.org/W2495086869","https://openalex.org/W2613332262","https://openalex.org/W4231527547","https://openalex.org/W4240894549","https://openalex.org/W4242867252","https://openalex.org/W6687668197"],"related_works":["https://openalex.org/W2128451253","https://openalex.org/W2009539361","https://openalex.org/W4200375091","https://openalex.org/W4225367228","https://openalex.org/W2341301344","https://openalex.org/W4226369685","https://openalex.org/W2910287997","https://openalex.org/W3214830231","https://openalex.org/W2157643825","https://openalex.org/W2188248784"],"abstract_inverted_index":{"Overcurrent":[0],"relays":[1,57,86],"are":[2,126],"widely":[3],"used":[4],"for":[5,63,134],"power":[6,46],"systems":[7,24],"protection.":[8],"Transmission":[9],"side":[10,124],"uses":[11],"more":[12,87],"directional":[13,55,84,99,119],"type":[14],"relays,":[15],"while":[16],"distribution":[17,123],"systems,":[18],"e.g.,":[19],"radial":[20],"and":[21,36,42,76,111],"ring-main":[22],"subtransmission":[23],"use":[25],"nondirectional":[26,91],"types.":[27],"The":[28],"fault":[29],"direction":[30,66],"may":[31],"be":[32],"forward":[33],"(between":[34,40],"relay":[35,41,120],"grid),":[37],"or":[38],"reverse":[39],"source),":[43],"the":[44,52,59,65,68,83,90,117,122,136],"normal":[45],"flow":[47],"being":[48],"from":[49],"source":[50],"to":[51],"grid.":[53,138],"Traditional":[54],"overcurrent":[56,85],"utilize":[58],"reference":[60],"voltage":[61,77],"phasor":[62],"estimating":[64],"of":[67,73,116],"fault.":[69],"This":[70,81],"requires":[71],"measurement":[72],"both":[74],"current":[75],"using":[78],"respective":[79],"sensors.":[80],"makes":[82],"costly":[88],"than":[89],"type.":[92],"In":[93],"this":[94],"paper,":[95],"a":[96,130],"novel":[97],"current-only":[98,118],"detection":[100],"possibility":[101],"is":[102,129],"highlighted":[103],"along":[104],"with":[105],"theoretical,":[106],"test":[107],"signal":[108],"analysis,":[109],"challenges":[110],"associated":[112],"solutions.":[113],"Possible":[114],"utilizations":[115],"in":[121],"protection":[125],"described,":[127],"which":[128],"key":[131],"focus":[132],"area":[133],"enabling":[135],"smart":[137]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":8},{"year":2021,"cited_by_count":8},{"year":2020,"cited_by_count":8},{"year":2019,"cited_by_count":5},{"year":2018,"cited_by_count":8},{"year":2017,"cited_by_count":11},{"year":2016,"cited_by_count":10},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":8},{"year":2013,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}