{"id":"https://openalex.org/W2061738154","doi":"https://doi.org/10.1109/tsg.2011.2180937","title":"Reliability Evaluation of Phasor Measurement Unit Using Monte Carlo Dynamic Fault Tree Method","display_name":"Reliability Evaluation of Phasor Measurement Unit Using Monte Carlo Dynamic Fault Tree Method","publication_year":2012,"publication_date":"2012-02-13","ids":{"openalex":"https://openalex.org/W2061738154","doi":"https://doi.org/10.1109/tsg.2011.2180937","mag":"2061738154"},"language":"en","primary_location":{"id":"doi:10.1109/tsg.2011.2180937","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2011.2180937","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100364029","display_name":"Peng Zhang","orcid":"https://orcid.org/0000-0001-6957-6874"},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Peng Zhang","raw_affiliation_strings":["Department of Electrical Engineering, Hong Kong Polytechnic University, Hong Kong, China","Dept. of Electr. Eng., Hong Kong Polytech. Univ., Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Hong Kong Polytechnic University, Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Hong Kong Polytech. Univ., Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5034113722","display_name":"Ka Wing Chan","orcid":"https://orcid.org/0000-0001-7462-0753"},"institutions":[{"id":"https://openalex.org/I14243506","display_name":"Hong Kong Polytechnic University","ror":"https://ror.org/0030zas98","country_code":"HK","type":"education","lineage":["https://openalex.org/I14243506"]}],"countries":["HK"],"is_corresponding":false,"raw_author_name":"Ka Wing Chan","raw_affiliation_strings":["Department of Electrical Engineering, Hong Kong Polytechnic University, Hong Kong, China","Dept. of Electr. Eng., Hong Kong Polytech. Univ., Hong Kong, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Hong Kong Polytechnic University, Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]},{"raw_affiliation_string":"Dept. of Electr. Eng., Hong Kong Polytech. Univ., Hong Kong, China","institution_ids":["https://openalex.org/I14243506"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I14243506"],"apc_list":null,"apc_paid":null,"fwci":5.8927,"has_fulltext":false,"cited_by_count":89,"citation_normalized_percentile":{"value":0.96558854,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":93,"max":99},"biblio":{"volume":"3","issue":"3","first_page":"1235","last_page":"1243"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.9965000152587891,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10917","display_name":"Smart Grid Security and Resilience","score":0.979200005531311,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/phasor-measurement-unit","display_name":"Phasor measurement unit","score":0.7926870584487915},{"id":"https://openalex.org/keywords/phasor","display_name":"Phasor","score":0.7301121354103088},{"id":"https://openalex.org/keywords/fault-tree-analysis","display_name":"Fault tree analysis","score":0.7259365320205688},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.6351209878921509},{"id":"https://openalex.org/keywords/monte-carlo-method","display_name":"Monte Carlo method","score":0.6181944608688354},{"id":"https://openalex.org/keywords/reliability","display_name":"Reliability (semiconductor)","score":0.6135832071304321},{"id":"https://openalex.org/keywords/redundancy","display_name":"Redundancy (engineering)","score":0.6041585206985474},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5294142365455627},{"id":"https://openalex.org/keywords/global-positioning-system","display_name":"Global Positioning System","score":0.5015535354614258},{"id":"https://openalex.org/keywords/reliability-block-diagram","display_name":"Reliability block diagram","score":0.43475258350372314},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.36379873752593994},{"id":"https://openalex.org/keywords/electric-power-system","display_name":"Electric power system","score":0.34090912342071533},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.1399526298046112},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.078785240650177}],"concepts":[{"id":"https://openalex.org/C2778229166","wikidata":"https://www.wikidata.org/wiki/Q8290","display_name":"Phasor measurement unit","level":5,"score":0.7926870584487915},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.7301121354103088},{"id":"https://openalex.org/C107094494","wikidata":"https://www.wikidata.org/wiki/Q428453","display_name":"Fault tree analysis","level":2,"score":0.7259365320205688},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.6351209878921509},{"id":"https://openalex.org/C19499675","wikidata":"https://www.wikidata.org/wiki/Q232207","display_name":"Monte Carlo method","level":2,"score":0.6181944608688354},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6135832071304321},{"id":"https://openalex.org/C152124472","wikidata":"https://www.wikidata.org/wiki/Q1204361","display_name":"Redundancy (engineering)","level":2,"score":0.6041585206985474},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5294142365455627},{"id":"https://openalex.org/C60229501","wikidata":"https://www.wikidata.org/wiki/Q18822","display_name":"Global Positioning System","level":2,"score":0.5015535354614258},{"id":"https://openalex.org/C18074226","wikidata":"https://www.wikidata.org/wiki/Q7310986","display_name":"Reliability block diagram","level":3,"score":0.43475258350372314},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.36379873752593994},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.34090912342071533},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.1399526298046112},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.078785240650177},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.0}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tsg.2011.2180937","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tsg.2011.2180937","pdf_url":null,"source":{"id":"https://openalex.org/S59604973","display_name":"IEEE Transactions on Smart Grid","issn_l":"1949-3053","issn":["1949-3053","1949-3061"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Smart Grid","raw_type":"journal-article"},{"id":"pmh:oai:ira.lib.polyu.edu.hk:10397/23440","is_oa":false,"landing_page_url":"http://hdl.handle.net/10397/23440","pdf_url":null,"source":{"id":"https://openalex.org/S4306400205","display_name":"PolyU Institutional Research Archive (Hong Kong Polytechnic University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I14243506","host_organization_name":"Hong Kong Polytechnic University","host_organization_lineage":["https://openalex.org/I14243506"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Journal/Magazine Article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W208605634","https://openalex.org/W1554758995","https://openalex.org/W1594556396","https://openalex.org/W1603152397","https://openalex.org/W1967395177","https://openalex.org/W1977748932","https://openalex.org/W1988567966","https://openalex.org/W2003782690","https://openalex.org/W2021424048","https://openalex.org/W2025057466","https://openalex.org/W2075028659","https://openalex.org/W2079038730","https://openalex.org/W2091608876","https://openalex.org/W2104993847","https://openalex.org/W2114159238","https://openalex.org/W2117557235","https://openalex.org/W2123733250","https://openalex.org/W2124588089","https://openalex.org/W2133773217","https://openalex.org/W2135569060","https://openalex.org/W2142643400","https://openalex.org/W2170449522","https://openalex.org/W2349531446","https://openalex.org/W2542523650","https://openalex.org/W3118245752","https://openalex.org/W6678362214","https://openalex.org/W6680124339","https://openalex.org/W6788445593","https://openalex.org/W7037107400"],"related_works":["https://openalex.org/W2084019529","https://openalex.org/W1963750642","https://openalex.org/W2167870875","https://openalex.org/W2914999846","https://openalex.org/W2912755537","https://openalex.org/W2188491941","https://openalex.org/W2130666994","https://openalex.org/W2696260070","https://openalex.org/W2787313303","https://openalex.org/W2348369745"],"abstract_inverted_index":{"Reliability":[0],"evaluation":[1,15,27,44,81],"of":[2,16,50,70,76,82,111,127,142,159],"phasor":[3],"measurement":[4],"unit":[5],"(PMU)":[6],"is":[7,38,52,151],"a":[8,24,145],"primary":[9],"key":[10],"element":[11],"in":[12,97],"the":[13,42,67,77,98,109,124,135,140,157],"reliability":[14,26,43,48,68,80,110,141],"wide-area":[17,147],"monitoring":[18],"system":[19],"(WAMS).":[20],"In":[21],"this":[22],"paper,":[23],"comprehensive":[25],"method":[28],"based":[29],"on":[30,45,108],"Monte":[31,62],"Carlo":[32,63],"dynamic":[33,55],"fault":[34,56],"tree":[35,57],"(MCDFT)":[36],"analysis":[37,92,117],"proposed":[39,78],"to":[40,65,121],"conduct":[41],"PMU.":[46,71,112,143],"The":[47,72],"model":[49],"PMU":[51,83,160],"constructed":[53],"using":[54,61],"modeling":[58],"and":[59,74,88,101,114,130],"analyzed":[60],"simulation":[64,87],"evaluate":[66],"indices":[69],"validity":[73],"advantages":[75],"MCDFT":[79],"were":[84],"verified":[85],"with":[86],"comparison":[89],"studies.":[90],"Importance":[91],"showed":[93],"that":[94,123],"basic":[95],"components":[96],"GPS":[99,128],"receiver":[100,129],"CPU":[102,131],"hardware":[103,132],"modules":[104],"have":[105],"high":[106],"impacts":[107],"Sensitivity":[113],"redundancy":[115,125],"design":[116,126],"are":[118],"then":[119],"applied":[120],"conclude":[122],"would":[133],"be":[134],"best":[136],"measure":[137],"for":[138,156],"improving":[139],"Finally,":[144],"self-adaptive":[146],"damping":[148],"control":[149],"scheme":[150],"taken":[152],"as":[153],"an":[154],"example":[155],"application":[158],"reliability.":[161]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":6},{"year":2023,"cited_by_count":5},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":11},{"year":2018,"cited_by_count":7},{"year":2017,"cited_by_count":10},{"year":2016,"cited_by_count":8},{"year":2015,"cited_by_count":9},{"year":2014,"cited_by_count":12},{"year":2013,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
