{"id":"https://openalex.org/W2153591206","doi":"https://doi.org/10.1109/tr.2010.2103596","title":"Periodic Inspection Optimization Models for a Repairable System Subject to Hidden Failures","display_name":"Periodic Inspection Optimization Models for a Repairable System Subject to Hidden Failures","publication_year":2011,"publication_date":"2011-01-13","ids":{"openalex":"https://openalex.org/W2153591206","doi":"https://doi.org/10.1109/tr.2010.2103596","mag":"2153591206"},"language":"en","primary_location":{"id":"doi:10.1109/tr.2010.2103596","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tr.2010.2103596","pdf_url":null,"source":{"id":"https://openalex.org/S87725633","display_name":"IEEE Transactions on Reliability","issn_l":"0018-9529","issn":["0018-9529","1558-1721"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Reliability","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5059636008","display_name":"Sharareh Taghipour","orcid":"https://orcid.org/0000-0003-3816-2462"},"institutions":[{"id":"https://openalex.org/I185261750","display_name":"University of Toronto","ror":"https://ror.org/03dbr7087","country_code":"CA","type":"education","lineage":["https://openalex.org/I185261750"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Sharareh Taghipour","raw_affiliation_strings":["Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ONT, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ONT, Canada","institution_ids":["https://openalex.org/I185261750"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080227774","display_name":"Dragan Banjevi\u0107","orcid":"https://orcid.org/0000-0002-5549-0655"},"institutions":[{"id":"https://openalex.org/I185261750","display_name":"University of Toronto","ror":"https://ror.org/03dbr7087","country_code":"CA","type":"education","lineage":["https://openalex.org/I185261750"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Dragan Banjevic","raw_affiliation_strings":["Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ONT, Canada"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, ONT, Canada","institution_ids":["https://openalex.org/I185261750"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I185261750"],"apc_list":null,"apc_paid":null,"fwci":19.8834,"has_fulltext":false,"cited_by_count":130,"citation_normalized_percentile":{"value":0.9928847,"is_in_top_1_percent":true,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":96,"max":100},"biblio":{"volume":"60","issue":"1","first_page":"275","last_page":"285"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11357","display_name":"Risk and Safety Analysis","score":0.9979000091552734,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T12423","display_name":"Software Reliability and Analysis Research","score":0.9925000071525574,"subfield":{"id":"https://openalex.org/subfields/1712","display_name":"Software"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/interval","display_name":"Interval (graph theory)","score":0.6993263959884644},{"id":"https://openalex.org/keywords/component","display_name":"Component (thermodynamics)","score":0.6628544330596924},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5337045788764954},{"id":"https://openalex.org/keywords/maintenance-engineering","display_name":"Maintenance engineering","score":0.4743572473526001},{"id":"https://openalex.org/keywords/mathematical-optimization","display_name":"Mathematical optimization","score":0.4699174463748932},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4393233060836792},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.3587636947631836},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3128991723060608},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.2990410327911377}],"concepts":[{"id":"https://openalex.org/C2778067643","wikidata":"https://www.wikidata.org/wiki/Q166507","display_name":"Interval (graph theory)","level":2,"score":0.6993263959884644},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.6628544330596924},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5337045788764954},{"id":"https://openalex.org/C23725684","wikidata":"https://www.wikidata.org/wiki/Q616377","display_name":"Maintenance engineering","level":2,"score":0.4743572473526001},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.4699174463748932},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4393233060836792},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.3587636947631836},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3128991723060608},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.2990410327911377},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C114614502","wikidata":"https://www.wikidata.org/wiki/Q76592","display_name":"Combinatorics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tr.2010.2103596","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tr.2010.2103596","pdf_url":null,"source":{"id":"https://openalex.org/S87725633","display_name":"IEEE Transactions on Reliability","issn_l":"0018-9529","issn":["0018-9529","1558-1721"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Reliability","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W606463773","https://openalex.org/W1977154607","https://openalex.org/W1979247873","https://openalex.org/W1985900655","https://openalex.org/W1997911366","https://openalex.org/W2003996217","https://openalex.org/W2009321353","https://openalex.org/W2011391307","https://openalex.org/W2024666582","https://openalex.org/W2048525832","https://openalex.org/W2053510719","https://openalex.org/W2057753869","https://openalex.org/W2084704513","https://openalex.org/W2084712111","https://openalex.org/W2085896549","https://openalex.org/W2093468313","https://openalex.org/W2096657153","https://openalex.org/W2107636880","https://openalex.org/W2118613329","https://openalex.org/W2119777027","https://openalex.org/W2120772990","https://openalex.org/W2122454250","https://openalex.org/W2145345033","https://openalex.org/W2159501681","https://openalex.org/W2161706532","https://openalex.org/W2322524800","https://openalex.org/W2494547223","https://openalex.org/W4233309072","https://openalex.org/W4236448029","https://openalex.org/W4245521939","https://openalex.org/W4299665420"],"related_works":["https://openalex.org/W2025178194","https://openalex.org/W1971749138","https://openalex.org/W2008730376","https://openalex.org/W2014857038","https://openalex.org/W2122594448","https://openalex.org/W2168011386","https://openalex.org/W2601840227","https://openalex.org/W2560663152","https://openalex.org/W1486463439","https://openalex.org/W1493851196"],"abstract_inverted_index":{"This":[0],"paper":[1],"proposes":[2],"a":[3,19,38,64,115,120],"model":[4],"to":[5,24,70],"find":[6],"an":[7],"optimal":[8,101],"periodic":[9,35],"inspection":[10,102],"interval":[11],"over":[12,88],"finite":[13,89],"and":[14,83,90],"infinite":[15,91],"time":[16,92],"horizons":[17],"for":[18,86,119],"multi-component":[20],"repairable":[21],"system":[22],"subject":[23],"hidden":[25],"failures.":[26],"The":[27,106],"components'":[28],"failures":[29,74],"can":[30],"only":[31],"be":[32],"rectified":[33],"at":[34],"inspections,":[36],"when":[37],"failed":[39],"component":[40],"is":[41,112],"either":[42],"minimally":[43],"repaired,":[44],"or":[45,60],"replaced":[46],"with":[47,57],"some":[48],"age":[49],"dependent":[50],"probabilities.":[51],"We":[52],"calculate":[53,71],"the":[54,97,100,110],"excepted":[55],"cost":[56],"delayed":[58],"replacement":[59],"minimal":[61,81],"repair":[62],"of":[63,73,80,96,99],"component.":[65],"Recursive":[66],"procedures":[67],"are":[68,104],"developed":[69],"probabilities":[72],"in":[75,109],"every":[76],"interval,":[77],"expected":[78,84],"number":[79],"repairs,":[82],"downtimes":[85],"optimization":[87],"horizons.":[93],"Numerical":[94],"examples":[95,111],"calculation":[98],"frequencies":[103],"given.":[105],"data":[107,118],"used":[108],"adapted":[113],"from":[114],"hospital's":[116],"maintenance":[117],"general":[121],"infusion":[122],"pump.":[123]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":3},{"year":2023,"cited_by_count":32},{"year":2022,"cited_by_count":8},{"year":2021,"cited_by_count":11},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":6},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":16},{"year":2015,"cited_by_count":18},{"year":2014,"cited_by_count":8},{"year":2013,"cited_by_count":4},{"year":2012,"cited_by_count":5}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
