{"id":"https://openalex.org/W4391759615","doi":"https://doi.org/10.1109/toh.2024.3364689","title":"A Hydraulic Haptic Actuator for Simulation of Cardiac Catheters","display_name":"A Hydraulic Haptic Actuator for Simulation of Cardiac Catheters","publication_year":2024,"publication_date":"2024-02-12","ids":{"openalex":"https://openalex.org/W4391759615","doi":"https://doi.org/10.1109/toh.2024.3364689","pmid":"https://pubmed.ncbi.nlm.nih.gov/38345951"},"language":"en","primary_location":{"id":"doi:10.1109/toh.2024.3364689","is_oa":false,"landing_page_url":"https://doi.org/10.1109/toh.2024.3364689","pdf_url":null,"source":{"id":"https://openalex.org/S38993383","display_name":"IEEE Transactions on Haptics","issn_l":"1939-1412","issn":["1939-1412","2329-4051","2334-0134"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Haptics","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5047289686","display_name":"Chengjie Li","orcid":"https://orcid.org/0000-0001-7652-0078"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chengjie Li","raw_affiliation_strings":["School of Mechanical Engineering, Jiangsu Ocean University, Lianyungang, China"],"raw_orcid":"https://orcid.org/0000-0001-7652-0078","affiliations":[{"raw_affiliation_string":"School of Mechanical Engineering, Jiangsu Ocean University, Lianyungang, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5007964198","display_name":"Doo Yong Lee","orcid":"https://orcid.org/0000-0003-4769-1331"},"institutions":[{"id":"https://openalex.org/I157485424","display_name":"Korea Advanced Institute of Science and Technology","ror":"https://ror.org/05apxxy63","country_code":"KR","type":"education","lineage":["https://openalex.org/I157485424"]}],"countries":["KR"],"is_corresponding":false,"raw_author_name":"Doo Yong Lee","raw_affiliation_strings":["Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea"],"raw_orcid":"https://orcid.org/0000-0003-4769-1331","affiliations":[{"raw_affiliation_string":"Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, South Korea","institution_ids":["https://openalex.org/I157485424"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0136106,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"17","issue":"3","first_page":"461","last_page":"470"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11687","display_name":"Teleoperation and Haptic Systems","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11687","display_name":"Teleoperation and Haptic Systems","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10868","display_name":"Soft Robotics and Applications","score":0.9786999821662903,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10916","display_name":"Surgical Simulation and Training","score":0.9768000245094299,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/haptic-technology","display_name":"Haptic technology","score":0.9053550958633423},{"id":"https://openalex.org/keywords/actuator","display_name":"Actuator","score":0.8274825811386108},{"id":"https://openalex.org/keywords/catheter","display_name":"Catheter","score":0.6246862411499023},{"id":"https://openalex.org/keywords/simulation","display_name":"Simulation","score":0.48478883504867554},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.42094987630844116},{"id":"https://openalex.org/keywords/control-theory","display_name":"Control theory (sociology)","score":0.4012230634689331},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.36891934275627136},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3500995337963104},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.3485678434371948},{"id":"https://openalex.org/keywords/surgery","display_name":"Surgery","score":0.19125404953956604},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.132676899433136},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.12395811080932617},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.09917619824409485}],"concepts":[{"id":"https://openalex.org/C152086174","wikidata":"https://www.wikidata.org/wiki/Q3030571","display_name":"Haptic technology","level":2,"score":0.9053550958633423},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.8274825811386108},{"id":"https://openalex.org/C2781267111","wikidata":"https://www.wikidata.org/wiki/Q652297","display_name":"Catheter","level":2,"score":0.6246862411499023},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.48478883504867554},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.42094987630844116},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4012230634689331},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.36891934275627136},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3500995337963104},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3485678434371948},{"id":"https://openalex.org/C141071460","wikidata":"https://www.wikidata.org/wiki/Q40821","display_name":"Surgery","level":1,"score":0.19125404953956604},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.132676899433136},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.12395811080932617},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.09917619824409485},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.0}],"mesh":[{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D003198","descriptor_name":"Computer Simulation","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012826","descriptor_name":"Silicone Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012826","descriptor_name":"Silicone Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012826","descriptor_name":"Silicone Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012826","descriptor_name":"Silicone Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D012826","descriptor_name":"Silicone Elastomers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014110","descriptor_name":"Touch","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D014584","descriptor_name":"User-Computer Interface","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D062906","descriptor_name":"Cardiac Catheters","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true}],"locations_count":2,"locations":[{"id":"doi:10.1109/toh.2024.3364689","is_oa":false,"landing_page_url":"https://doi.org/10.1109/toh.2024.3364689","pdf_url":null,"source":{"id":"https://openalex.org/S38993383","display_name":"IEEE Transactions on Haptics","issn_l":"1939-1412","issn":["1939-1412","2329-4051","2334-0134"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Haptics","raw_type":"journal-article"},{"id":"pmid:38345951","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/38345951","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on haptics","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G1047382781","display_name":null,"funder_award_id":"1711111113","funder_id":"https://openalex.org/F4320322120","funder_display_name":"National Research Foundation of Korea"}],"funders":[{"id":"https://openalex.org/F4320322120","display_name":"National Research Foundation of Korea","ror":"https://ror.org/013aysd81"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":49,"referenced_works":["https://openalex.org/W57203137","https://openalex.org/W1586893858","https://openalex.org/W1758210173","https://openalex.org/W1966531554","https://openalex.org/W1999590572","https://openalex.org/W2009473978","https://openalex.org/W2022157562","https://openalex.org/W2042839974","https://openalex.org/W2071244056","https://openalex.org/W2072082492","https://openalex.org/W2077238250","https://openalex.org/W2078528033","https://openalex.org/W2086613819","https://openalex.org/W2101535012","https://openalex.org/W2116135069","https://openalex.org/W2153015913","https://openalex.org/W2160215454","https://openalex.org/W2163742851","https://openalex.org/W2164160147","https://openalex.org/W2294215545","https://openalex.org/W2318027444","https://openalex.org/W2332852586","https://openalex.org/W2414749422","https://openalex.org/W2510038405","https://openalex.org/W2547274897","https://openalex.org/W2576348450","https://openalex.org/W2581382109","https://openalex.org/W2586205312","https://openalex.org/W2824642132","https://openalex.org/W2909128381","https://openalex.org/W2915040685","https://openalex.org/W2921483293","https://openalex.org/W2956070412","https://openalex.org/W2964093142","https://openalex.org/W2994205609","https://openalex.org/W3001744918","https://openalex.org/W3037722175","https://openalex.org/W3090621705","https://openalex.org/W3092906413","https://openalex.org/W3094478436","https://openalex.org/W3129368054","https://openalex.org/W3157193804","https://openalex.org/W3196160372","https://openalex.org/W4206224914","https://openalex.org/W4220925926","https://openalex.org/W4224071776","https://openalex.org/W6602384173","https://openalex.org/W6679839282","https://openalex.org/W6683769470"],"related_works":["https://openalex.org/W156716224","https://openalex.org/W2111871955","https://openalex.org/W3175380930","https://openalex.org/W1989694608","https://openalex.org/W2139876914","https://openalex.org/W1986738380","https://openalex.org/W2642061445","https://openalex.org/W4233260495","https://openalex.org/W3094485622","https://openalex.org/W2731583012"],"abstract_inverted_index":{"This":[0],"article":[1],"presents":[2],"a":[3,25,155],"haptic":[4,16,22,75,143,170],"actuator":[5,23,144,171],"made":[6],"of":[7,41,79,95,110,157],"silicone":[8],"rubber":[9],"to":[10,53,72,89,100,118,121,124,134,148],"provide":[11],"both":[12],"passive":[13,151],"and":[14,63,103,154,183],"active":[15,74,160],"forces":[17],"for":[18,164],"catheter":[19,56,67,81,112,167],"simulations.":[20],"The":[21,77,108,169],"has":[24],"torus":[26],"outer":[27],"shape":[28],"with":[29,178],"an":[30],"ellipse-shaped":[31],"inside":[32,51],"chamber":[33,43],"which":[34],"is":[35,83],"actuated":[36],"by":[37,44,85],"hydraulic":[38],"pressure.":[39],"Expansion":[40],"the":[42,50,55,66,69,80,90,96,106,111,141,165,174],"providing":[45,86],"positive":[46],"pressure":[47,88],"can":[48,61,114,145,172],"squeeze":[49],"passage":[52,82,113],"resist":[54],"traveling":[57],"through.":[58,136],"Further":[59],"expansion":[60],"hold":[62],"push":[64],"back":[65],"in":[68],"axial":[70],"direction":[71],"render":[73,146,173],"forces.":[76],"size":[78],"increased":[84],"negative":[87],"chamber,":[91],"allowing":[92],"various":[93],"diameters":[94],"actual":[97],"medical":[98,132],"catheters":[99,133],"be":[101,115],"used":[102],"exchanged":[104],"during":[105],"simulation.":[107,168],"diameter":[109],"enlarged":[116],"up":[117],"1.6":[119],"times":[120],"allow":[122],"5":[123],"7":[125],"Fr":[126,128],"(1":[127],"=":[129],"1/3":[130],"mm)":[131],"pass":[135],"Experiment":[137],"results":[138],"show":[139],"that":[140],"proposed":[142],"0":[147],"2.0":[149,158],"N":[150,159,180],"feedback":[152,161],"force,":[153,162],"maximum":[156],"sufficient":[163],"cardiac":[166],"commanded":[175],"force":[176],"profile":[177],"0.10":[179],"RMS":[181],"(root-mean-squares)":[182],"10.51%":[184],"L2-norm":[185],"relative":[186],"errors.":[187]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
