{"id":"https://openalex.org/W4417304977","doi":"https://doi.org/10.1109/tmi.2025.3643618","title":"Multifocal Optical-Resolution Photoacoustic Microscopy With a Masked Single-Element Transducer","display_name":"Multifocal Optical-Resolution Photoacoustic Microscopy With a Masked Single-Element Transducer","publication_year":2025,"publication_date":"2025-12-12","ids":{"openalex":"https://openalex.org/W4417304977","doi":"https://doi.org/10.1109/tmi.2025.3643618","pmid":"https://pubmed.ncbi.nlm.nih.gov/41385414"},"language":"en","primary_location":{"id":"doi:10.1109/tmi.2025.3643618","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tmi.2025.3643618","pdf_url":null,"source":{"id":"https://openalex.org/S58069681","display_name":"IEEE Transactions on Medical Imaging","issn_l":"0278-0062","issn":["0278-0062","1558-254X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Medical Imaging","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC13056231/pdf/nihms-2157915.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Xiaofei Luo","orcid":"https://orcid.org/0000-0002-3005-4240"},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Xiaofei Luo","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":"https://orcid.org/0000-0002-3005-4240","affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5000314739","display_name":"Rui Cao","orcid":"https://orcid.org/0000-0003-4444-7528"},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Rui Cao","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":"https://orcid.org/0000-0003-4444-7528","affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Peng Hu","orcid":"https://orcid.org/0000-0002-2933-1239"},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Peng Hu","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":"https://orcid.org/0000-0002-2933-1239","affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5049729161","display_name":"Yilin Luo","orcid":"https://orcid.org/0000-0002-4611-3049"},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yilin Luo","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":"https://orcid.org/0000-0002-4611-3049","affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023395566","display_name":"Yushun Zeng","orcid":"https://orcid.org/0000-0001-5995-4085"},"institutions":[{"id":"https://openalex.org/I4210099443","display_name":"Southern California Eye Institute","ror":"https://ror.org/012mmb732","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I4210099443"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yushun Zeng","raw_affiliation_strings":["Alfred E. Mann Department of Biomedical Engineering, USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA"],"raw_orcid":"https://orcid.org/0000-0001-5995-4085","affiliations":[{"raw_affiliation_string":"Alfred E. Mann Department of Biomedical Engineering, USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA","institution_ids":["https://openalex.org/I4210099443"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5084614459","display_name":"Yide Zhang","orcid":"https://orcid.org/0000-0002-9463-3970"},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Yide Zhang","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":"https://orcid.org/0000-0002-9463-3970","affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028898035","display_name":"Manxiu Cui","orcid":"https://orcid.org/0000-0003-0788-9511"},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Manxiu Cui","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":"https://orcid.org/0000-0003-0788-9511","affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081250646","display_name":"Qifa Zhou","orcid":"https://orcid.org/0000-0003-1527-3020"},"institutions":[{"id":"https://openalex.org/I4210099443","display_name":"Southern California Eye Institute","ror":"https://ror.org/012mmb732","country_code":"US","type":"healthcare","lineage":["https://openalex.org/I4210099443"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Qifa Zhou","raw_affiliation_strings":["Alfred E. Mann Department of Biomedical Engineering, USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA"],"raw_orcid":"https://orcid.org/0000-0003-1527-3020","affiliations":[{"raw_affiliation_string":"Alfred E. Mann Department of Biomedical Engineering, USC Roski Eye Institute, University of Southern California, Los Angeles, CA, USA","institution_ids":["https://openalex.org/I4210099443"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022809072","display_name":"Geng Ku","orcid":null},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Geng Ku","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5008233636","display_name":"Lihong V. Wang","orcid":"https://orcid.org/0000-0001-9783-4383"},"institutions":[{"id":"https://openalex.org/I122411786","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055","country_code":"US","type":"education","lineage":["https://openalex.org/I122411786"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Lihong V. Wang","raw_affiliation_strings":["Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Andrew and Peggy Cherng Department of Medical Engineering, Caltech Optical Imaging Laboratory, Pasadena, CA, USA","institution_ids":["https://openalex.org/I122411786"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.31711062,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"45","issue":"5","first_page":"2015","last_page":"2022"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12015","display_name":"Photoacoustic and Ultrasonic Imaging","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11856","display_name":"Thermography and Photoacoustic Techniques","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11996","display_name":"Random lasers and scattering media","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/3102","display_name":"Acoustics and Ultrasonics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/laser","display_name":"Laser","score":0.7150999903678894},{"id":"https://openalex.org/keywords/photoacoustic-imaging-in-biomedicine","display_name":"Photoacoustic imaging in biomedicine","score":0.6227999925613403},{"id":"https://openalex.org/keywords/acoustic-microscopy","display_name":"Acoustic microscopy","score":0.5867999792098999},{"id":"https://openalex.org/keywords/transducer","display_name":"Transducer","score":0.5685999989509583},{"id":"https://openalex.org/keywords/photoacoustic-doppler-effect","display_name":"Photoacoustic Doppler effect","score":0.5533000230789185},{"id":"https://openalex.org/keywords/microscopy","display_name":"Microscopy","score":0.5461000204086304},{"id":"https://openalex.org/keywords/photoacoustic-effect","display_name":"Photoacoustic effect","score":0.5347999930381775},{"id":"https://openalex.org/keywords/microscope","display_name":"Microscope","score":0.4921000003814697},{"id":"https://openalex.org/keywords/resolution","display_name":"Resolution (logic)","score":0.44290000200271606}],"concepts":[{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.7243000268936157},{"id":"https://openalex.org/C520434653","wikidata":"https://www.wikidata.org/wiki/Q38867","display_name":"Laser","level":2,"score":0.7150999903678894},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.651199996471405},{"id":"https://openalex.org/C54932901","wikidata":"https://www.wikidata.org/wiki/Q7187705","display_name":"Photoacoustic imaging in biomedicine","level":2,"score":0.6227999925613403},{"id":"https://openalex.org/C2781117724","wikidata":"https://www.wikidata.org/wiki/Q4674694","display_name":"Acoustic microscopy","level":3,"score":0.5867999792098999},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.5685999989509583},{"id":"https://openalex.org/C31771446","wikidata":"https://www.wikidata.org/wiki/Q7187700","display_name":"Photoacoustic Doppler effect","level":3,"score":0.5533000230789185},{"id":"https://openalex.org/C147080431","wikidata":"https://www.wikidata.org/wiki/Q1074953","display_name":"Microscopy","level":2,"score":0.5461000204086304},{"id":"https://openalex.org/C163740662","wikidata":"https://www.wikidata.org/wiki/Q7187702","display_name":"Photoacoustic effect","level":3,"score":0.5347999930381775},{"id":"https://openalex.org/C67649825","wikidata":"https://www.wikidata.org/wiki/Q196538","display_name":"Microscope","level":2,"score":0.4921000003814697},{"id":"https://openalex.org/C138268822","wikidata":"https://www.wikidata.org/wiki/Q1051925","display_name":"Resolution (logic)","level":2,"score":0.44290000200271606},{"id":"https://openalex.org/C81288441","wikidata":"https://www.wikidata.org/wiki/Q20736125","display_name":"Ultrasonic sensor","level":2,"score":0.44209998846054077},{"id":"https://openalex.org/C205372480","wikidata":"https://www.wikidata.org/wiki/Q210521","display_name":"Image resolution","level":2,"score":0.3928000032901764},{"id":"https://openalex.org/C77017923","wikidata":"https://www.wikidata.org/wiki/Q912313","display_name":"Optical microscope","level":3,"score":0.3402000069618225},{"id":"https://openalex.org/C141349535","wikidata":"https://www.wikidata.org/wiki/Q1361664","display_name":"Laser scanning","level":3,"score":0.3237000107765198},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.3091000020503998},{"id":"https://openalex.org/C119666444","wikidata":"https://www.wikidata.org/wiki/Q5977280","display_name":"Temporal resolution","level":2,"score":0.3050000071525574},{"id":"https://openalex.org/C125287762","wikidata":"https://www.wikidata.org/wiki/Q1758948","display_name":"Absorption (acoustics)","level":2,"score":0.3003999888896942},{"id":"https://openalex.org/C2776141515","wikidata":"https://www.wikidata.org/wiki/Q1274479","display_name":"Repetition (rhetorical device)","level":2,"score":0.29809999465942383},{"id":"https://openalex.org/C92630104","wikidata":"https://www.wikidata.org/wiki/Q4115103","display_name":"Optical imaging","level":2,"score":0.2953000068664551},{"id":"https://openalex.org/C3261483","wikidata":"https://www.wikidata.org/wiki/Q119565","display_name":"Frame rate","level":2,"score":0.2808000147342682},{"id":"https://openalex.org/C121477167","wikidata":"https://www.wikidata.org/wiki/Q17154002","display_name":"Semiconductor laser theory","level":3,"score":0.2782999873161316},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.27730000019073486},{"id":"https://openalex.org/C132771110","wikidata":"https://www.wikidata.org/wiki/Q506922","display_name":"Adaptive optics","level":2,"score":0.272599995136261},{"id":"https://openalex.org/C2777286522","wikidata":"https://www.wikidata.org/wiki/Q900415","display_name":"Photoacoustic spectroscopy","level":3,"score":0.27129998803138733},{"id":"https://openalex.org/C31601959","wikidata":"https://www.wikidata.org/wiki/Q931309","display_name":"Medical imaging","level":2,"score":0.25859999656677246},{"id":"https://openalex.org/C17163034","wikidata":"https://www.wikidata.org/wiki/Q390528","display_name":"Fiber laser","level":3,"score":0.2581999897956848},{"id":"https://openalex.org/C109592283","wikidata":"https://www.wikidata.org/wiki/Q7187705","display_name":"Photoacoustic tomography","level":3,"score":0.2500999867916107}],"mesh":[{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004867","descriptor_name":"Equipment Design","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D007091","descriptor_name":"Image Processing, Computer-Assisted","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D008853","descriptor_name":"Microscopy","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D008853","descriptor_name":"Microscopy","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D008853","descriptor_name":"Microscopy","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D008853","descriptor_name":"Microscopy","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D014159","descriptor_name":"Transducers","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":true},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true},{"descriptor_ui":"D061088","descriptor_name":"Photoacoustic Techniques","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":true}],"locations_count":3,"locations":[{"id":"doi:10.1109/tmi.2025.3643618","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tmi.2025.3643618","pdf_url":null,"source":{"id":"https://openalex.org/S58069681","display_name":"IEEE Transactions on Medical Imaging","issn_l":"0278-0062","issn":["0278-0062","1558-254X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Medical Imaging","raw_type":"journal-article"},{"id":"pmid:41385414","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/41385414","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on medical imaging","raw_type":null},{"id":"pmh:oai:pubmedcentral.nih.gov:13056231","is_oa":true,"landing_page_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC13056231/","pdf_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC13056231/pdf/nihms-2157915.pdf","source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Trans Med Imaging","raw_type":"Text"}],"best_oa_location":{"id":"pmh:oai:pubmedcentral.nih.gov:13056231","is_oa":true,"landing_page_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC13056231/","pdf_url":"https://pmc.ncbi.nlm.nih.gov/articles/PMC13056231/pdf/nihms-2157915.pdf","source":{"id":"https://openalex.org/S2764455111","display_name":"PubMed Central","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Trans Med Imaging","raw_type":"Text"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2368930801","display_name":null,"funder_award_id":"R00 EB034298","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G2880707374","display_name":null,"funder_award_id":"R01 EB028277","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G5150011950","display_name":null,"funder_award_id":"T32 EB027629","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G6034453372","display_name":null,"funder_award_id":"K99 EB035645","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"},{"id":"https://openalex.org/G803532093","display_name":null,"funder_award_id":"R35 CA220436","funder_id":"https://openalex.org/F4320332161","funder_display_name":"National Institutes of Health"}],"funders":[{"id":"https://openalex.org/F4320309398","display_name":"California Institute of Technology","ror":"https://ror.org/05dxps055"},{"id":"https://openalex.org/F4320332161","display_name":"National Institutes of Health","ror":"https://ror.org/01cwqze88"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4417304977.pdf","grobid_xml":"https://content.openalex.org/works/W4417304977.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Optical-resolution":[0],"photoacoustic":[1,47,85],"microscopy":[2,48],"(OR-PAM)":[3],"can":[4,138],"visualize":[5],"cellular-level":[6],"wavelength-dependent":[7],"optical":[8,58],"absorption":[9],"with":[10,50,103],"high":[11],"resolution":[12],"and":[13,61,145],"sensitivity.":[14],"However,":[15],"the":[16,25,31,56,104,111,127],"imaging":[17,97,151],"speed":[18,98],"of":[19,34,73],"OR-PAM":[20,102,125,143],"has":[21],"been":[22],"limited":[23],"by":[24],"laser":[26,37,106,117,128],"repetition":[27,107,129],"rate":[28,130],"due":[29],"to":[30,83,100,141],"point-by-point":[32],"scanning":[33],"a":[35,51,62,114,132],"focused":[36],"beam.":[38],"To":[39],"overcome":[40],"this":[41],"limitation,":[42],"we":[43],"propose":[44],"multifocal":[45],"optical-resolution":[46],"(MOR-PAM)":[49],"single-element":[52],"ultrasonic":[53],"transducer,":[54],"leveraging":[55],"diffractive":[57],"element":[59],"(DOE)":[60],"custom-designed":[63],"encoding":[64],"acoustic":[65,79],"mask.":[66],"The":[67,78,135],"DOE":[68],"generates":[69],"8":[70],"focal":[71,89],"spots":[72],"$3~\\mu":[74],"$":[75],"m":[76],"diameter.":[77],"mask":[80],"was":[81],"designed":[82],"encode":[84],"signals":[86],"from":[87],"different":[88],"spots.":[90],"MOR-PAM":[91,112],"achieved":[92],"an":[93],"8-fold":[94],"increase":[95],"in":[96,131],"compared":[99],"conventional":[101],"same":[105],"rate.":[108],"We":[109],"demonstrated":[110],"using":[113],"266":[115],"nm":[116],"at":[118],"10":[119],"KHz,":[120],"providing":[121],"solutions":[122],"for":[123],"rapid":[124],"beyond":[126],"cost-effective":[133],"way.":[134],"proposed":[136],"method":[137],"be":[139],"applied":[140],"versatile":[142],"configurations":[144],"enable":[146],"new":[147],"applications":[148],"where":[149],"high-speed":[150],"is":[152],"critical.":[153]},"counts_by_year":[],"updated_date":"2026-05-08T13:12:06.581006","created_date":"2025-12-12T00:00:00"}
