{"id":"https://openalex.org/W3087481541","doi":"https://doi.org/10.1109/tmi.2020.3024722","title":"Performance Evaluation and Compatibility Studies of a Compact Preclinical Scanner for Simultaneous PET/MR Imaging at 7 Tesla","display_name":"Performance Evaluation and Compatibility Studies of a Compact Preclinical Scanner for Simultaneous PET/MR Imaging at 7 Tesla","publication_year":2020,"publication_date":"2020-09-21","ids":{"openalex":"https://openalex.org/W3087481541","doi":"https://doi.org/10.1109/tmi.2020.3024722","mag":"3087481541","pmid":"https://pubmed.ncbi.nlm.nih.gov/32956042"},"language":"en","primary_location":{"id":"doi:10.1109/tmi.2020.3024722","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tmi.2020.3024722","pdf_url":"https://ieeexplore.ieee.org/ielx7/42/9310721/09201099.pdf","source":{"id":"https://openalex.org/S58069681","display_name":"IEEE Transactions on Medical Imaging","issn_l":"0278-0062","issn":["0278-0062","1558-254X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Medical Imaging","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://ieeexplore.ieee.org/ielx7/42/9310721/09201099.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021708651","display_name":"Alan Courteau","orcid":"https://orcid.org/0000-0002-0960-1334"},"institutions":[{"id":"https://openalex.org/I177064439","display_name":"Universit\u00e9 de Bourgogne","ror":"https://ror.org/03k1bsr36","country_code":"FR","type":"education","lineage":["https://openalex.org/I177064439"]},{"id":"https://openalex.org/I4210118524","display_name":"Universit\u00e9 Bourgogne Franche-Comt\u00e9","ror":"https://ror.org/02dn7x778","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210118524"]},{"id":"https://openalex.org/I4387152817","display_name":"ImViA - Imagerie et Vision Artificielle","ror":"https://ror.org/020n3gx08","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4387152817","https://openalex.org/I4405253280"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Alan Courteau","raw_affiliation_strings":["Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","Imagerie et Vision Artificielle [Dijon]"],"raw_orcid":"https://orcid.org/0000-0002-0960-1334","affiliations":[{"raw_affiliation_string":"Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","institution_ids":["https://openalex.org/I4210118524"]},{"raw_affiliation_string":"Imagerie et Vision Artificielle [Dijon]","institution_ids":["https://openalex.org/I177064439","https://openalex.org/I4387152817"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112336138","display_name":"John McGrath","orcid":null},"institutions":[{"id":"https://openalex.org/I4210154655","display_name":"Materials Solutions (United Kingdom)","ror":"https://ror.org/0504yp647","country_code":"GB","type":"company","lineage":["https://openalex.org/I4210154655"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"John McGrath","raw_affiliation_strings":["MR Solutions Ltd., Guildford, U.K","MR Solutions Guildford"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"MR Solutions Ltd., Guildford, U.K","institution_ids":["https://openalex.org/I4210154655"]},{"raw_affiliation_string":"MR Solutions Guildford","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5039324116","display_name":"Paul M. Walker","orcid":"https://orcid.org/0000-0001-6693-3936"},"institutions":[{"id":"https://openalex.org/I177064439","display_name":"Universit\u00e9 de Bourgogne","ror":"https://ror.org/03k1bsr36","country_code":"FR","type":"education","lineage":["https://openalex.org/I177064439"]},{"id":"https://openalex.org/I4210094685","display_name":"Centre Georges Fran\u00e7ois Leclerc","ror":"https://ror.org/00pjqzf38","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4210094685","https://openalex.org/I4210141925"]},{"id":"https://openalex.org/I4387152817","display_name":"ImViA - Imagerie et Vision Artificielle","ror":"https://ror.org/020n3gx08","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4387152817","https://openalex.org/I4405253280"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Paul Michael Walker","raw_affiliation_strings":["CHU Fran\u00e7ois Mitterrand, Dijon, France","Centre Hospitalier Universitaire de Dijon - H\u00f4pital Fran\u00e7ois Mitterrand","Imagerie et Vision Artificielle [Dijon]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CHU Fran\u00e7ois Mitterrand, Dijon, France","institution_ids":["https://openalex.org/I4210094685"]},{"raw_affiliation_string":"Centre Hospitalier Universitaire de Dijon - H\u00f4pital Fran\u00e7ois Mitterrand","institution_ids":[]},{"raw_affiliation_string":"Imagerie et Vision Artificielle [Dijon]","institution_ids":["https://openalex.org/I177064439","https://openalex.org/I4387152817"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075106489","display_name":"R Pegg","orcid":"https://orcid.org/0000-0002-2974-6194"},"institutions":[{"id":"https://openalex.org/I4210154655","display_name":"Materials Solutions (United Kingdom)","ror":"https://ror.org/0504yp647","country_code":"GB","type":"company","lineage":["https://openalex.org/I4210154655"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Rosie Pegg","raw_affiliation_strings":["MR Solutions Ltd., Guildford, U.K","MR Solutions Guildford"],"raw_orcid":"https://orcid.org/0000-0002-2974-6194","affiliations":[{"raw_affiliation_string":"MR Solutions Ltd., Guildford, U.K","institution_ids":["https://openalex.org/I4210154655"]},{"raw_affiliation_string":"MR Solutions Guildford","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112566367","display_name":"Gary V. Martin","orcid":null},"institutions":[{"id":"https://openalex.org/I4210154655","display_name":"Materials Solutions (United Kingdom)","ror":"https://ror.org/0504yp647","country_code":"GB","type":"company","lineage":["https://openalex.org/I4210154655"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Gary Martin","raw_affiliation_strings":["MR Solutions Ltd., Guildford, U.K","MR Solutions Guildford"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"MR Solutions Ltd., Guildford, U.K","institution_ids":["https://openalex.org/I4210154655"]},{"raw_affiliation_string":"MR Solutions Guildford","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062959307","display_name":"Ruslan Garipov","orcid":null},"institutions":[{"id":"https://openalex.org/I4210154655","display_name":"Materials Solutions (United Kingdom)","ror":"https://ror.org/0504yp647","country_code":"GB","type":"company","lineage":["https://openalex.org/I4210154655"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Ruslan Garipov","raw_affiliation_strings":["MR Solutions Ltd., Guildford, U.K","MR Solutions Guildford"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"MR Solutions Ltd., Guildford, U.K","institution_ids":["https://openalex.org/I4210154655"]},{"raw_affiliation_string":"MR Solutions Guildford","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5009260950","display_name":"Peter Doughty","orcid":null},"institutions":[{"id":"https://openalex.org/I4210154655","display_name":"Materials Solutions (United Kingdom)","ror":"https://ror.org/0504yp647","country_code":"GB","type":"company","lineage":["https://openalex.org/I4210154655"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Peter Doughty","raw_affiliation_strings":["MR Solutions Ltd., Guildford, U.K","MR Solutions Guildford"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"MR Solutions Ltd., Guildford, U.K","institution_ids":["https://openalex.org/I4210154655"]},{"raw_affiliation_string":"MR Solutions Guildford","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081409183","display_name":"Alexandre Cochet","orcid":"https://orcid.org/0009-0009-1187-652X"},"institutions":[{"id":"https://openalex.org/I177064439","display_name":"Universit\u00e9 de Bourgogne","ror":"https://ror.org/03k1bsr36","country_code":"FR","type":"education","lineage":["https://openalex.org/I177064439"]},{"id":"https://openalex.org/I4210094685","display_name":"Centre Georges Fran\u00e7ois Leclerc","ror":"https://ror.org/00pjqzf38","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4210094685","https://openalex.org/I4210141925"]},{"id":"https://openalex.org/I4210118524","display_name":"Universit\u00e9 Bourgogne Franche-Comt\u00e9","ror":"https://ror.org/02dn7x778","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210118524"]},{"id":"https://openalex.org/I4387152817","display_name":"ImViA - Imagerie et Vision Artificielle","ror":"https://ror.org/020n3gx08","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4387152817","https://openalex.org/I4405253280"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Alexandre Cochet","raw_affiliation_strings":["CHU Fran\u00e7ois Mitterrand, Dijon, France","Georges-Fran\u00e7ois Leclerc Cancer Centre, Unicancer, Dijon, France","Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","Centre Hospitalier Universitaire de Dijon - H\u00f4pital Fran\u00e7ois Mitterrand","Imagerie et Vision Artificielle [Dijon]","Service de M\u00e9decine Nucl\u00e9aire, Centre Georges-Fran\u00e7ois Leclerc [Dijon]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"CHU Fran\u00e7ois Mitterrand, Dijon, France","institution_ids":["https://openalex.org/I4210094685"]},{"raw_affiliation_string":"Georges-Fran\u00e7ois Leclerc Cancer Centre, Unicancer, Dijon, France","institution_ids":["https://openalex.org/I4210094685"]},{"raw_affiliation_string":"Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","institution_ids":["https://openalex.org/I4210118524"]},{"raw_affiliation_string":"Centre Hospitalier Universitaire de Dijon - H\u00f4pital Fran\u00e7ois Mitterrand","institution_ids":[]},{"raw_affiliation_string":"Imagerie et Vision Artificielle [Dijon]","institution_ids":["https://openalex.org/I177064439","https://openalex.org/I4387152817"]},{"raw_affiliation_string":"Service de M\u00e9decine Nucl\u00e9aire, Centre Georges-Fran\u00e7ois Leclerc [Dijon]","institution_ids":["https://openalex.org/I4210094685"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081178144","display_name":"Fran\u00e7ois Brunotte","orcid":"https://orcid.org/0000-0003-0700-9780"},"institutions":[{"id":"https://openalex.org/I177064439","display_name":"Universit\u00e9 de Bourgogne","ror":"https://ror.org/03k1bsr36","country_code":"FR","type":"education","lineage":["https://openalex.org/I177064439"]},{"id":"https://openalex.org/I4210118524","display_name":"Universit\u00e9 Bourgogne Franche-Comt\u00e9","ror":"https://ror.org/02dn7x778","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210118524"]},{"id":"https://openalex.org/I4387152817","display_name":"ImViA - Imagerie et Vision Artificielle","ror":"https://ror.org/020n3gx08","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4387152817","https://openalex.org/I4405253280"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Francois Brunotte","raw_affiliation_strings":["Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","Imagerie et Vision Artificielle [Dijon]"],"raw_orcid":"https://orcid.org/0000-0003-0700-9780","affiliations":[{"raw_affiliation_string":"Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","institution_ids":["https://openalex.org/I4210118524"]},{"raw_affiliation_string":"Imagerie et Vision Artificielle [Dijon]","institution_ids":["https://openalex.org/I177064439","https://openalex.org/I4387152817"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080113143","display_name":"Jean\u2010Marc Vrigneaud","orcid":"https://orcid.org/0000-0002-3441-7520"},"institutions":[{"id":"https://openalex.org/I177064439","display_name":"Universit\u00e9 de Bourgogne","ror":"https://ror.org/03k1bsr36","country_code":"FR","type":"education","lineage":["https://openalex.org/I177064439"]},{"id":"https://openalex.org/I4210094685","display_name":"Centre Georges Fran\u00e7ois Leclerc","ror":"https://ror.org/00pjqzf38","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4210094685","https://openalex.org/I4210141925"]},{"id":"https://openalex.org/I4210118524","display_name":"Universit\u00e9 Bourgogne Franche-Comt\u00e9","ror":"https://ror.org/02dn7x778","country_code":"FR","type":"education","lineage":["https://openalex.org/I4210118524"]},{"id":"https://openalex.org/I4387152817","display_name":"ImViA - Imagerie et Vision Artificielle","ror":"https://ror.org/020n3gx08","country_code":"FR","type":"facility","lineage":["https://openalex.org/I4387152817","https://openalex.org/I4405253280"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Jean-Marc Vrigneaud","raw_affiliation_strings":["Georges-Fran\u00e7ois Leclerc Cancer Centre, Unicancer, Dijon, France","Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","Imagerie et Vision Artificielle [Dijon]","Service de M\u00e9decine Nucl\u00e9aire, Centre Georges-Fran\u00e7ois Leclerc [Dijon]"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Georges-Fran\u00e7ois Leclerc Cancer Centre, Unicancer, Dijon, France","institution_ids":["https://openalex.org/I4210094685"]},{"raw_affiliation_string":"Laboratoire Imagerie et Vision Artificielle, EA 7535, University of Bourgogne-Franche-Comt\u00e9, Dijon, France","institution_ids":["https://openalex.org/I4210118524"]},{"raw_affiliation_string":"Imagerie et Vision Artificielle [Dijon]","institution_ids":["https://openalex.org/I177064439","https://openalex.org/I4387152817"]},{"raw_affiliation_string":"Service de M\u00e9decine Nucl\u00e9aire, Centre Georges-Fran\u00e7ois Leclerc [Dijon]","institution_ids":["https://openalex.org/I4210094685"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2045,"currency":"USD","value_usd":2045},"apc_paid":null,"fwci":1.1594,"has_fulltext":true,"cited_by_count":13,"citation_normalized_percentile":{"value":0.81513283,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"40","issue":"1","first_page":"205","last_page":"217"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10522","display_name":"Medical Imaging Techniques and Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10522","display_name":"Medical Imaging Techniques and Applications","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11216","display_name":"Radiation Detection and Scintillator Technologies","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/3108","display_name":"Radiation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/imaging-phantom","display_name":"Imaging phantom","score":0.801342248916626},{"id":"https://openalex.org/keywords/scanner","display_name":"Scanner","score":0.6348522305488586},{"id":"https://openalex.org/keywords/electromagnetic-coil","display_name":"Electromagnetic coil","score":0.6269482374191284},{"id":"https://openalex.org/keywords/image-quality","display_name":"Image quality","score":0.584856390953064},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.5617154240608215},{"id":"https://openalex.org/keywords/nuclear-medicine","display_name":"Nuclear medicine","score":0.5451906323432922},{"id":"https://openalex.org/keywords/full-width-at-half-maximum","display_name":"Full width at half maximum","score":0.5192187428474426},{"id":"https://openalex.org/keywords/detector","display_name":"Detector","score":0.49661022424697876},{"id":"https://openalex.org/keywords/silicon-photomultiplier","display_name":"Silicon photomultiplier","score":0.48895442485809326},{"id":"https://openalex.org/keywords/positron-emission-tomography","display_name":"Positron emission tomography","score":0.4458080232143402},{"id":"https://openalex.org/keywords/lyso","display_name":"Lyso-","score":0.44444820284843445},{"id":"https://openalex.org/keywords/image-resolution","display_name":"Image resolution","score":0.43269747495651245},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4101671278476715},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.3930002748966217},{"id":"https://openalex.org/keywords/scintillator","display_name":"Scintillator","score":0.1185905933380127},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.11849701404571533},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.08700919151306152}],"concepts":[{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.801342248916626},{"id":"https://openalex.org/C2779751349","wikidata":"https://www.wikidata.org/wiki/Q1474480","display_name":"Scanner","level":2,"score":0.6348522305488586},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.6269482374191284},{"id":"https://openalex.org/C55020928","wikidata":"https://www.wikidata.org/wiki/Q3813865","display_name":"Image quality","level":3,"score":0.584856390953064},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.5617154240608215},{"id":"https://openalex.org/C2989005","wikidata":"https://www.wikidata.org/wiki/Q214963","display_name":"Nuclear medicine","level":1,"score":0.5451906323432922},{"id":"https://openalex.org/C108649604","wikidata":"https://www.wikidata.org/wiki/Q1065170","display_name":"Full width at half maximum","level":2,"score":0.5192187428474426},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.49661022424697876},{"id":"https://openalex.org/C104335537","wikidata":"https://www.wikidata.org/wiki/Q1085747","display_name":"Silicon photomultiplier","level":4,"score":0.48895442485809326},{"id":"https://openalex.org/C2775842073","wikidata":"https://www.wikidata.org/wiki/Q208376","display_name":"Positron emission tomography","level":2,"score":0.4458080232143402},{"id":"https://openalex.org/C2780330291","wikidata":"https://www.wikidata.org/wiki/Q6710262","display_name":"Lyso-","level":4,"score":0.44444820284843445},{"id":"https://openalex.org/C205372480","wikidata":"https://www.wikidata.org/wiki/Q210521","display_name":"Image resolution","level":2,"score":0.43269747495651245},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4101671278476715},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.3930002748966217},{"id":"https://openalex.org/C161694136","wikidata":"https://www.wikidata.org/wiki/Q910990","display_name":"Scintillator","level":3,"score":0.1185905933380127},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.11849701404571533},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.08700919151306152},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.0},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000818","descriptor_name":"Animals","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006257","descriptor_name":"Head","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006257","descriptor_name":"Head","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006257","descriptor_name":"Head","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D008279","descriptor_name":"Magnetic Resonance Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011846","descriptor_name":"Radio Waves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011846","descriptor_name":"Radio Waves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D011846","descriptor_name":"Radio Waves","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D019047","descriptor_name":"Phantoms, Imaging","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D049268","descriptor_name":"Positron-Emission Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D049268","descriptor_name":"Positron-Emission Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D049268","descriptor_name":"Positron-Emission Tomography","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051379","descriptor_name":"Mice","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051381","descriptor_name":"Rats","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051381","descriptor_name":"Rats","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D051381","descriptor_name":"Rats","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false}],"locations_count":3,"locations":[{"id":"doi:10.1109/tmi.2020.3024722","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tmi.2020.3024722","pdf_url":"https://ieeexplore.ieee.org/ielx7/42/9310721/09201099.pdf","source":{"id":"https://openalex.org/S58069681","display_name":"IEEE Transactions on Medical Imaging","issn_l":"0278-0062","issn":["0278-0062","1558-254X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Medical Imaging","raw_type":"journal-article"},{"id":"pmid:32956042","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/32956042","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on medical imaging","raw_type":"Journal Article"},{"id":"pmh:oai:HAL:hal-03118426v1","is_oa":true,"landing_page_url":"https://ube.hal.science/hal-03118426","pdf_url":"https://ube.hal.science/hal-03118426v1/document","source":{"id":"https://openalex.org/S4306402512","display_name":"HAL (Le Centre pour la Communication Scientifique Directe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1294671590","host_organization_name":"Centre National de la Recherche Scientifique","host_organization_lineage":["https://openalex.org/I1294671590"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Medical Imaging, 2021, 40 (1), pp.205 - 217. &#x27E8;10.1109/tmi.2020.3024722&#x27E9;","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.1109/tmi.2020.3024722","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tmi.2020.3024722","pdf_url":"https://ieeexplore.ieee.org/ielx7/42/9310721/09201099.pdf","source":{"id":"https://openalex.org/S58069681","display_name":"IEEE Transactions on Medical Imaging","issn_l":"0278-0062","issn":["0278-0062","1558-254X"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Medical Imaging","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7699999809265137,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G3858294855","display_name":"IRM et TEP coupl\u00e9es en imagerie pr\u00e9-clinique","funder_award_id":"ANR-10-EQPX-0005","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"},{"id":"https://openalex.org/G5386645538","display_name":null,"funder_award_id":"ANR\u201010\u2010EQPX\u201005\u201001","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"},{"id":"https://openalex.org/G7240651115","display_name":null,"funder_award_id":"ANR-10","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"},{"id":"https://openalex.org/G8510727784","display_name":null,"funder_award_id":"ANR-10-EQPX","funder_id":"https://openalex.org/F4320320883","funder_display_name":"Agence Nationale de la Recherche"}],"funders":[{"id":"https://openalex.org/F4320320883","display_name":"Agence Nationale de la Recherche","ror":"https://ror.org/00rbzpz17"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3087481541.pdf","grobid_xml":"https://content.openalex.org/works/W3087481541.grobid-xml"},"referenced_works_count":33,"referenced_works":["https://openalex.org/W126204668","https://openalex.org/W2012521254","https://openalex.org/W2025463179","https://openalex.org/W2034117422","https://openalex.org/W2052932094","https://openalex.org/W2083682890","https://openalex.org/W2092814340","https://openalex.org/W2119674653","https://openalex.org/W2125742970","https://openalex.org/W2127523527","https://openalex.org/W2133175443","https://openalex.org/W2142266796","https://openalex.org/W2151273857","https://openalex.org/W2286550235","https://openalex.org/W2340316031","https://openalex.org/W2344182582","https://openalex.org/W2416995348","https://openalex.org/W2475107576","https://openalex.org/W2514386604","https://openalex.org/W2544463190","https://openalex.org/W2546379232","https://openalex.org/W2754064880","https://openalex.org/W2762546926","https://openalex.org/W2795239830","https://openalex.org/W2808030994","https://openalex.org/W2896705020","https://openalex.org/W2903769242","https://openalex.org/W2941873273","https://openalex.org/W2971294649","https://openalex.org/W2982248955","https://openalex.org/W3012611725","https://openalex.org/W3015568659","https://openalex.org/W6679520547"],"related_works":["https://openalex.org/W2138226061","https://openalex.org/W3038595806","https://openalex.org/W2966550174","https://openalex.org/W2043800983","https://openalex.org/W2542554006","https://openalex.org/W2052301970","https://openalex.org/W2783176426","https://openalex.org/W2543562986","https://openalex.org/W2752806289","https://openalex.org/W2162266040"],"abstract_inverted_index":{"We":[0],"present":[1],"the":[2,58,93,97,124,145,149,197,210],"design":[3],"and":[4,17,36,51,73,82,110,118,133,141,189,209,240],"performance":[5],"of":[6,41,44,48,148,196,212,243],"a":[7,65,180],"new":[8],"compact":[9],"preclinical":[10],"system":[11],"combining":[12],"positron":[13],"emission":[14],"tomography":[15],"(PET)":[16],"magnetic":[18,229],"resonance":[19],"imaging":[20],"(MRI)":[21],"for":[22],"simultaneous":[23,88,248],"scans.":[24,249],"The":[25,60,174,216,227,238],"PET":[26,61,72],"contains":[27],"sixteen":[28],"SiPM-based":[29],"detector":[30],"heads":[31],"arranged":[32],"in":[33,64],"two":[34],"octagons":[35],"covers":[37],"an":[38],"axial":[39,146],"field":[40,230],"view":[42],"(FOV)":[43],"102.5":[45],"mm.":[46,173,237],"Depth":[47],"interaction":[49],"effects":[50],"detector's":[52],"temperature":[53],"variations":[54],"are":[55],"compensated":[56],"by":[57],"system.":[59],"is":[62],"integrated":[63],"dry":[66],"magnet":[67],"operating":[68],"at":[69,107,113,130,136,157,163],"7":[70],"T.":[71],"MRI":[74],"characteristics":[75],"were":[76,90,104,245],"assessed":[77],"complying":[78],"with":[79,117,140,179,187],"international":[80],"standards":[81],"interferences":[83],"between":[84],"both":[85],"subsystems":[86],"during":[87,247],"scans":[89],"addressed.":[91],"For":[92,122],"rat":[94],"size":[95],"phantom,":[96],"peak":[98,125,175],"noise":[99],"equivalent":[100],"count":[101,218],"rates":[102],"(NECR)":[103],"96.4":[105],"kcps":[106,112,129,135],"30.2":[108],"MBq":[109,115,132,138],"132.3":[111],"28.4":[114],"respectively":[116,139],"without":[119,142,191],"RF":[120],"coil.":[121,143,192],"mouse,":[123],"NECR":[126],"was":[127,185,214,221,232],"300.0":[128],"34.5":[131],"426.9":[134],"34.3":[137],"At":[144],"centre":[147],"FOV,":[150],"spatial":[151],"resolutions":[152],"expressed":[153],"as":[154],"full":[155,161],"width":[156,162],"half":[158],"maximum":[159,165],"/":[160],"tenth":[164],"(FWHM/FWTM)":[166],"ranged":[167,204],"from":[168,205],"1.69/3.19":[169],"mm":[170],"to":[171,207,224],"2.39/4.87":[172],"absolute":[176],"sensitivity":[177],"obtained":[178],"250-750":[181],"keV":[182],"energy":[183],"window":[184],"7.5%":[186],"coil":[188],"7.9%":[190],"Spill":[193],"over":[194,235],"ratios":[195],"NEMA":[198],"NU4-2008":[199],"image":[200,217],"quality":[201],"(NEMA-IQ)":[202],"phantom":[203],"0.25":[206],"0.96":[208],"percentage":[211],"non-uniformity":[213],"5.7%.":[215],"versus":[219],"activity":[220],"linear":[222],"up":[223],"40":[225,236],"MBq.":[226],"principal":[228],"variation":[231],"0.03":[233],"ppm/mm":[234],"qualitative":[239],"quantitative":[241],"aspects":[242],"data":[244],"preserved":[246]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":5}],"updated_date":"2026-08-28T12:50:07.497085","created_date":"2025-10-10T00:00:00"}
