{"id":"https://openalex.org/W2098559306","doi":"https://doi.org/10.1109/titb.2009.2037619","title":"Toward a Highly Accurate Ambulatory System for Clinical Gait Analysis via UWB Radios","display_name":"Toward a Highly Accurate Ambulatory System for Clinical Gait Analysis via UWB Radios","publication_year":2009,"publication_date":"2009-12-16","ids":{"openalex":"https://openalex.org/W2098559306","doi":"https://doi.org/10.1109/titb.2009.2037619","mag":"2098559306","pmid":"https://pubmed.ncbi.nlm.nih.gov/20007056"},"language":"en","primary_location":{"id":"doi:10.1109/titb.2009.2037619","is_oa":false,"landing_page_url":"https://doi.org/10.1109/titb.2009.2037619","pdf_url":null,"source":{"id":"https://openalex.org/S68937846","display_name":"IEEE Transactions on Information Technology in Biomedicine","issn_l":"1089-7771","issn":["1089-7771","1558-0032"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Information Technology in Biomedicine","raw_type":"journal-article"},"type":"article","indexed_in":["crossref","pubmed"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029474759","display_name":"Heba Shaban","orcid":"https://orcid.org/0000-0001-6603-8915"},"institutions":[{"id":"https://openalex.org/I859038795","display_name":"Virginia Tech","ror":"https://ror.org/02smfhw86","country_code":"US","type":"education","lineage":["https://openalex.org/I859038795"]},{"id":"https://openalex.org/I4210086935","display_name":"Arab Academy for Science, Technology, and Maritime Transport","ror":null,"country_code":"EG","type":null,"lineage":["https://openalex.org/I4210086935"]}],"countries":["EG","US"],"is_corresponding":true,"raw_author_name":"H.A. Shaban","raw_affiliation_strings":["Virginia Polytechnic Institute and State University at Alexandria (VT-MENA), Arab Academy for Science and Technology, Alexandria 1029, Egypt. hshaban@vt.edu","Virginia Tech Research Group, Blacksburg, VA, USA"],"affiliations":[{"raw_affiliation_string":"Virginia Polytechnic Institute and State University at Alexandria (VT-MENA), Arab Academy for Science and Technology, Alexandria 1029, Egypt. hshaban@vt.edu","institution_ids":["https://openalex.org/I4210086935"]},{"raw_affiliation_string":"Virginia Tech Research Group, Blacksburg, VA, USA","institution_ids":["https://openalex.org/I859038795"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072434761","display_name":"Mohamad Abou El-Nasr","orcid":"https://orcid.org/0000-0002-7694-6615"},"institutions":[{"id":"https://openalex.org/I859038795","display_name":"Virginia Tech","ror":"https://ror.org/02smfhw86","country_code":"US","type":"education","lineage":["https://openalex.org/I859038795"]},{"id":"https://openalex.org/I59272784","display_name":"Arab Academy for Science, Technology, and Maritime Transport","ror":"https://ror.org/0004vyj87","country_code":"EG","type":"education","lineage":["https://openalex.org/I59272784"]}],"countries":["EG","US"],"is_corresponding":false,"raw_author_name":"M.A. El-Nasr","raw_affiliation_strings":["Department of Computer Engineering, Arab Academy for Science, Technology and Maritime Transport, Alexandria, Egypt","Virginia Tech Research Group, Blacksburg, VA, USA"],"affiliations":[{"raw_affiliation_string":"Department of Computer Engineering, Arab Academy for Science, Technology and Maritime Transport, Alexandria, Egypt","institution_ids":["https://openalex.org/I59272784"]},{"raw_affiliation_string":"Virginia Tech Research Group, Blacksburg, VA, USA","institution_ids":["https://openalex.org/I859038795"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5052487611","display_name":"R. Michael Buehrer","orcid":"https://orcid.org/0000-0002-7196-1154"},"institutions":[{"id":"https://openalex.org/I859038795","display_name":"Virginia Tech","ror":"https://ror.org/02smfhw86","country_code":"US","type":"education","lineage":["https://openalex.org/I859038795"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"R.M. Buehrer","raw_affiliation_strings":["Virginia Tech Research Group, Blacksburg, VA, USA"],"affiliations":[{"raw_affiliation_string":"Virginia Tech Research Group, Blacksburg, VA, USA","institution_ids":["https://openalex.org/I859038795"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5029474759"],"corresponding_institution_ids":["https://openalex.org/I4210086935","https://openalex.org/I859038795"],"apc_list":null,"apc_paid":null,"fwci":4.4469,"has_fulltext":false,"cited_by_count":68,"citation_normalized_percentile":{"value":0.944334,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"14","issue":"2","first_page":"284","last_page":"291"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11932","display_name":"Wireless Body Area Networks","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10326","display_name":"Indoor and Outdoor Localization Technologies","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12024","display_name":"Ultra-Wideband Communications Technology","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ranging","display_name":"Ranging","score":0.9143605828285217},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.6538645625114441},{"id":"https://openalex.org/keywords/ultra-wideband","display_name":"Ultra-wideband","score":0.63310307264328},{"id":"https://openalex.org/keywords/transceiver","display_name":"Transceiver","score":0.6207446455955505},{"id":"https://openalex.org/keywords/wearable-computer","display_name":"Wearable computer","score":0.6022041440010071},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.5506753325462341},{"id":"https://openalex.org/keywords/additive-white-gaussian-noise","display_name":"Additive white Gaussian noise","score":0.5092884302139282},{"id":"https://openalex.org/keywords/gait","display_name":"Gait","score":0.50014328956604},{"id":"https://openalex.org/keywords/channel","display_name":"Channel (broadcasting)","score":0.457232803106308},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.36492806673049927},{"id":"https://openalex.org/keywords/real-time-computing","display_name":"Real-time computing","score":0.34857845306396484},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.22131815552711487},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.20687231421470642},{"id":"https://openalex.org/keywords/embedded-system","display_name":"Embedded system","score":0.14644762873649597},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.10228681564331055}],"concepts":[{"id":"https://openalex.org/C115051666","wikidata":"https://www.wikidata.org/wiki/Q6522493","display_name":"Ranging","level":2,"score":0.9143605828285217},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6538645625114441},{"id":"https://openalex.org/C21916231","wikidata":"https://www.wikidata.org/wiki/Q851424","display_name":"Ultra-wideband","level":2,"score":0.63310307264328},{"id":"https://openalex.org/C7720470","wikidata":"https://www.wikidata.org/wiki/Q954187","display_name":"Transceiver","level":3,"score":0.6207446455955505},{"id":"https://openalex.org/C150594956","wikidata":"https://www.wikidata.org/wiki/Q1334829","display_name":"Wearable computer","level":2,"score":0.6022041440010071},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.5506753325462341},{"id":"https://openalex.org/C169334058","wikidata":"https://www.wikidata.org/wiki/Q353292","display_name":"Additive white Gaussian noise","level":3,"score":0.5092884302139282},{"id":"https://openalex.org/C151800584","wikidata":"https://www.wikidata.org/wiki/Q2370000","display_name":"Gait","level":2,"score":0.50014328956604},{"id":"https://openalex.org/C127162648","wikidata":"https://www.wikidata.org/wiki/Q16858953","display_name":"Channel (broadcasting)","level":2,"score":0.457232803106308},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.36492806673049927},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.34857845306396484},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.22131815552711487},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20687231421470642},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.14644762873649597},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.10228681564331055},{"id":"https://openalex.org/C42407357","wikidata":"https://www.wikidata.org/wiki/Q521","display_name":"Physiology","level":1,"score":0.0}],"mesh":[{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D000465","descriptor_name":"Algorithms","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D001696","descriptor_name":"Biomechanical Phenomena","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001696","descriptor_name":"Biomechanical Phenomena","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D001696","descriptor_name":"Biomechanical Phenomena","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D004581","descriptor_name":"Electronics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004581","descriptor_name":"Electronics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D004581","descriptor_name":"Electronics","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D005684","descriptor_name":"Gait","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D005684","descriptor_name":"Gait","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D005684","descriptor_name":"Gait","qualifier_ui":"Q000502","qualifier_name":"physiology","is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D006801","descriptor_name":"Humans","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D008991","descriptor_name":"Monitoring, Physiologic","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D011845","descriptor_name":"Radio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011845","descriptor_name":"Radio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D011845","descriptor_name":"Radio","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D012815","descriptor_name":"Signal Processing, Computer-Assisted","qualifier_ui":null,"qualifier_name":null,"is_major_topic":true},{"descriptor_ui":"D016011","descriptor_name":"Normal Distribution","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016011","descriptor_name":"Normal Distribution","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D016011","descriptor_name":"Normal Distribution","qualifier_ui":null,"qualifier_name":null,"is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000295","qualifier_name":"instrumentation","is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false},{"descriptor_ui":"D017216","descriptor_name":"Telemedicine","qualifier_ui":"Q000379","qualifier_name":"methods","is_major_topic":false}],"locations_count":2,"locations":[{"id":"doi:10.1109/titb.2009.2037619","is_oa":false,"landing_page_url":"https://doi.org/10.1109/titb.2009.2037619","pdf_url":null,"source":{"id":"https://openalex.org/S68937846","display_name":"IEEE Transactions on Information Technology in Biomedicine","issn_l":"1089-7771","issn":["1089-7771","1558-0032"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Information Technology in Biomedicine","raw_type":"journal-article"},{"id":"pmid:20007056","is_oa":false,"landing_page_url":"https://pubmed.ncbi.nlm.nih.gov/20007056","pdf_url":null,"source":{"id":"https://openalex.org/S4306525036","display_name":"PubMed","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1299303238","host_organization_name":"National Institutes of Health","host_organization_lineage":["https://openalex.org/I1299303238"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE transactions on information technology in biomedicine : a publication of the IEEE Engineering in Medicine and Biology Society","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5299999713897705,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W55236019","https://openalex.org/W1567412329","https://openalex.org/W1971173149","https://openalex.org/W1982627577","https://openalex.org/W2011067748","https://openalex.org/W2037603996","https://openalex.org/W2045686382","https://openalex.org/W2076776363","https://openalex.org/W2119553672","https://openalex.org/W2133045983","https://openalex.org/W2143928268","https://openalex.org/W2166618391","https://openalex.org/W2169241775","https://openalex.org/W2171540294","https://openalex.org/W2541247865","https://openalex.org/W2544110504","https://openalex.org/W2544785911","https://openalex.org/W2906342460","https://openalex.org/W4249470309","https://openalex.org/W4249817017","https://openalex.org/W6643063527","https://openalex.org/W6684508163","https://openalex.org/W6685304702","https://openalex.org/W6729259153"],"related_works":["https://openalex.org/W2121815169","https://openalex.org/W2104043593","https://openalex.org/W4240182038","https://openalex.org/W2126864775","https://openalex.org/W4307330872","https://openalex.org/W3156095002","https://openalex.org/W2088455853","https://openalex.org/W2056168215","https://openalex.org/W2941646359","https://openalex.org/W2955199696"],"abstract_inverted_index":{"In":[0],"this":[1],"paper,":[2],"we":[3],"propose":[4],"and":[5,9,42,50,137,141],"investigate":[6],"a":[7,19,70],"low-cost":[8],"low-complexity":[10],"wireless":[11],"ambulatory":[12],"human":[13],"locomotion":[14],"tracking":[15],"system":[16,40,64],"that":[17],"provides":[18,98],"high":[20],"ranging":[21,71,101],"accuracy":[22,72,102,111,118],"(intersensor":[23],"distance)":[24],"suitable":[25,130],"for":[26,58,123,131,138],"the":[27,99,117,121,124,139],"assessment":[28,142],"of":[29,68,73,143],"clinical":[30,134],"gait":[31,135],"analysis":[32],"using":[33,53],"wearable":[34],"ultra":[35],"wideband":[36],"(UWB)":[37],"transceivers.":[38],"The":[39,62,109],"design":[41],"transceiver":[43],"performance":[44],"are":[45],"presented":[46],"in":[47,88,120,133],"additive-white-gaussian":[48],"noise":[49],"realistic":[51,89],"channels,":[52],"industry":[54],"accepted":[55],"channel":[56],"models":[57],"body":[59],"area":[60],"networks.":[61],"proposed":[63],"is":[65,112],"theoretically":[66],"capable":[67],"providing":[69],"0.11":[74],"cm":[75],"error":[76],"at":[77,83,103],"distances":[78],"equivalent":[79],"to":[80],"interarker":[81],"distances,":[82],"an":[84,104],"18":[85],"dB":[86],"SNR":[87,105],"on-body":[90],"UWB":[91],"channels.":[92],"Based":[93],"on":[94],"real":[95],"measurements,":[96],"it":[97,129],"target":[100],"=":[106],"20":[107],"dB.":[108],"achievable":[110],"ten":[113],"times":[114],"better":[115],"than":[116],"reported":[119],"literature":[122],"intermarker-distance":[125],"measurement.":[126],"This":[127],"makes":[128],"use":[132],"analysis,":[136],"characterization":[140],"unstable":[144],"mobility":[145],"diseases,":[146],"such":[147],"as":[148],"Parkinson's":[149],"disease.":[150]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3},{"year":2019,"cited_by_count":6},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":8},{"year":2014,"cited_by_count":7},{"year":2013,"cited_by_count":11},{"year":2012,"cited_by_count":11}],"updated_date":"2026-01-13T01:12:25.745995","created_date":"2025-10-10T00:00:00"}
