{"id":"https://openalex.org/W4414221864","doi":"https://doi.org/10.1109/tim.2025.3608340","title":"High-Sensitivity Operation of Unshielded Radio Frequency Atomic Magnetometers Using Phase-Lock Techniques","display_name":"High-Sensitivity Operation of Unshielded Radio Frequency Atomic Magnetometers Using Phase-Lock Techniques","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4414221864","doi":"https://doi.org/10.1109/tim.2025.3608340"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2025.3608340","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2025.3608340","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://discovery.ucl.ac.uk/10215724/1/Renzoni_High-Sensitivity%20Operation%20of%20Unshielded%20Radio%20Frequency%20Atomic%20Magnetometers%20Using%20Phase-Lock%20Techniques_AAM.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5082959508","display_name":"Han Yao","orcid":"https://orcid.org/0000-0003-3354-252X"},"institutions":[{"id":"https://openalex.org/I36399199","display_name":"Nanjing University of Science and Technology","ror":"https://ror.org/00xp9wg62","country_code":"CN","type":"education","lineage":["https://openalex.org/I36399199"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Han Yao","raw_affiliation_strings":["School of Physics, Nanjing University of Science and Technology, Nanjing, China"],"raw_orcid":"https://orcid.org/0000-0003-3354-252X","affiliations":[{"raw_affiliation_string":"School of Physics, Nanjing University of Science and Technology, Nanjing, China","institution_ids":["https://openalex.org/I36399199"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5071593652","display_name":"Ferruccio Renzoni","orcid":"https://orcid.org/0000-0002-4286-5323"},"institutions":[{"id":"https://openalex.org/I45129253","display_name":"University College London","ror":"https://ror.org/02jx3x895","country_code":"GB","type":"education","lineage":["https://openalex.org/I124357947","https://openalex.org/I45129253"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Ferruccio Renzoni","raw_affiliation_strings":["Department of Physics and Astronomy, University College London, London, U.K","Department of Physics and Astronomy, University College London, Gower Street, London, UK"],"raw_orcid":"https://orcid.org/0000-0002-4286-5323","affiliations":[{"raw_affiliation_string":"Department of Physics and Astronomy, University College London, London, U.K","institution_ids":["https://openalex.org/I45129253"]},{"raw_affiliation_string":"Department of Physics and Astronomy, University College London, Gower Street, London, UK","institution_ids":["https://openalex.org/I45129253"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.8364,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.86130685,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":98},"biblio":{"volume":"74","issue":null,"first_page":"1","last_page":"9"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12004","display_name":"Advanced Frequency and Time Standards","score":0.9761999845504761,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9675999879837036,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/magnetometer","display_name":"Magnetometer","score":0.9172000288963318},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.7003999948501587},{"id":"https://openalex.org/keywords/fluxgate-compass","display_name":"Fluxgate compass","score":0.6956999897956848},{"id":"https://openalex.org/keywords/compensation","display_name":"Compensation (psychology)","score":0.6802999973297119},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.38920000195503235},{"id":"https://openalex.org/keywords/radio-frequency","display_name":"Radio frequency","score":0.38760000467300415},{"id":"https://openalex.org/keywords/magnetic-noise","display_name":"Magnetic noise","score":0.31450000405311584}],"concepts":[{"id":"https://openalex.org/C153946474","wikidata":"https://www.wikidata.org/wiki/Q333921","display_name":"Magnetometer","level":3,"score":0.9172000288963318},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.7003999948501587},{"id":"https://openalex.org/C28044941","wikidata":"https://www.wikidata.org/wiki/Q2735870","display_name":"Fluxgate compass","level":4,"score":0.6956999897956848},{"id":"https://openalex.org/C2780023022","wikidata":"https://www.wikidata.org/wiki/Q1338171","display_name":"Compensation (psychology)","level":2,"score":0.6802999973297119},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.420199990272522},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4018999934196472},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3937000036239624},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.38920000195503235},{"id":"https://openalex.org/C74064498","wikidata":"https://www.wikidata.org/wiki/Q3396184","display_name":"Radio frequency","level":2,"score":0.38760000467300415},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.38609999418258667},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.33500000834465027},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.32739999890327454},{"id":"https://openalex.org/C2983215976","wikidata":"https://www.wikidata.org/wiki/Q5141464","display_name":"Magnetic noise","level":3,"score":0.31450000405311584},{"id":"https://openalex.org/C196597080","wikidata":"https://www.wikidata.org/wiki/Q227467","display_name":"Atomic clock","level":2,"score":0.29899999499320984},{"id":"https://openalex.org/C2779833257","wikidata":"https://www.wikidata.org/wiki/Q2663154","display_name":"Magnetic separation","level":2,"score":0.2971999943256378},{"id":"https://openalex.org/C104892082","wikidata":"https://www.wikidata.org/wiki/Q17156810","display_name":"Low frequency","level":2,"score":0.290800005197525},{"id":"https://openalex.org/C11930861","wikidata":"https://www.wikidata.org/wiki/Q181417","display_name":"Frequency modulation","level":3,"score":0.2833999991416931},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.2782999873161316},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.274399995803833},{"id":"https://openalex.org/C8590192","wikidata":"https://www.wikidata.org/wiki/Q1054694","display_name":"Frequency response","level":2,"score":0.25780001282691956},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.2515999972820282},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.250900000333786}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tim.2025.3608340","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2025.3608340","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:eprints.ucl.ac.uk.OAI2:10215724","is_oa":true,"landing_page_url":"https://discovery.ucl.ac.uk/id/eprint/10215724/","pdf_url":"https://discovery.ucl.ac.uk/10215724/1/Renzoni_High-Sensitivity%20Operation%20of%20Unshielded%20Radio%20Frequency%20Atomic%20Magnetometers%20Using%20Phase-Lock%20Techniques_AAM.pdf","source":{"id":"https://openalex.org/S4306400024","display_name":"UCL Discovery (University College London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I45129253","host_organization_name":"University College London","host_organization_lineage":["https://openalex.org/I45129253"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement , 74     , Article ARTN 9535009. (2025)","raw_type":"Article"}],"best_oa_location":{"id":"pmh:oai:eprints.ucl.ac.uk.OAI2:10215724","is_oa":true,"landing_page_url":"https://discovery.ucl.ac.uk/id/eprint/10215724/","pdf_url":"https://discovery.ucl.ac.uk/10215724/1/Renzoni_High-Sensitivity%20Operation%20of%20Unshielded%20Radio%20Frequency%20Atomic%20Magnetometers%20Using%20Phase-Lock%20Techniques_AAM.pdf","source":{"id":"https://openalex.org/S4306400024","display_name":"UCL Discovery (University College London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I45129253","host_organization_name":"University College London","host_organization_lineage":["https://openalex.org/I45129253"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement , 74     , Article ARTN 9535009. (2025)","raw_type":"Article"},"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G6576579947","display_name":null,"funder_award_id":"30925020225","funder_id":"https://openalex.org/F4320335787","funder_display_name":"Fundamental Research Funds for the Central Universities"},{"id":"https://openalex.org/G7957430525","display_name":null,"funder_award_id":"30925010210","funder_id":"https://openalex.org/F4320335787","funder_display_name":"Fundamental Research Funds for the Central Universities"}],"funders":[{"id":"https://openalex.org/F4320335787","display_name":"Fundamental Research Funds for the Central Universities","ror":null}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4414221864.pdf","grobid_xml":"https://content.openalex.org/works/W4414221864.grobid-xml"},"referenced_works_count":20,"referenced_works":["https://openalex.org/W2017741778","https://openalex.org/W2020486671","https://openalex.org/W2026391396","https://openalex.org/W2127834952","https://openalex.org/W2293842411","https://openalex.org/W2766839228","https://openalex.org/W2791548393","https://openalex.org/W2798186117","https://openalex.org/W2887944635","https://openalex.org/W2942548774","https://openalex.org/W2969486786","https://openalex.org/W3005689553","https://openalex.org/W3134664738","https://openalex.org/W4307009163","https://openalex.org/W4307043448","https://openalex.org/W4318947526","https://openalex.org/W4362557799","https://openalex.org/W4384828974","https://openalex.org/W4401542757","https://openalex.org/W4404657483"],"related_works":[],"abstract_inverted_index":{"High":[0],"sensitivity":[1,36],"operation":[2],"of":[3,12,15,25,47,87,90],"radio-frequency":[4],"atomic":[5,49],"magnetometers":[6],"in":[7,65,104],"unshielded":[8,66],"environment":[9,32,81],"requires":[10],"compensation":[11],"low-frequency":[13],"fluctuations":[14],"the":[16,23,30,45,48,75,79,85,98],"ambient":[17],"magnetic":[18,31,80],"field.":[19],"Here":[20],"we":[21],"demonstrate":[22],"use":[24],"phase-lock":[26,69,99],"techniques":[27],"to":[28,74],"stabilise":[29],"and":[33,54,93],"achieve":[34],"high":[35,38],"at":[37],"frequencies.":[39],"This":[40],"is":[41,60,71,82,95],"achieved":[42],"by":[43,62],"using":[44],"output":[46],"magnetometer":[50],"both":[51],"for":[52,55],"stabilisation":[53],"measurement":[56],"purposes.":[57],"The":[58,68],"approach":[59,70,77,100],"validated":[61],"a":[63,88],"proof-of-concept":[64],"environment.":[67],"also":[72],"compared":[73],"standard":[76],"where":[78],"stabilised":[83],"with":[84],"help":[86],"set":[89],"fluxgate":[91],"magnetometers,":[92],"it":[94],"shown":[96],"that":[97],"features":[101],"superior":[102],"performances":[103],"signal":[105],"detection.":[106]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
