{"id":"https://openalex.org/W4410492148","doi":"https://doi.org/10.1109/tim.2025.3571111","title":"In Situ Measurement of Vapor Cell Temperature in Optically Pumped Magnetometer Based on Light Absorption","display_name":"In Situ Measurement of Vapor Cell Temperature in Optically Pumped Magnetometer Based on Light Absorption","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4410492148","doi":"https://doi.org/10.1109/tim.2025.3571111"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2025.3571111","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2025.3571111","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009440902","display_name":"Haoyuan Sun","orcid":"https://orcid.org/0009-0008-3421-2497"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haoyuan Sun","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China"],"raw_orcid":"https://orcid.org/0009-0008-3421-2497","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006126871","display_name":"Xinda Song","orcid":"https://orcid.org/0000-0003-2837-7646"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xinda Song","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-2837-7646","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001132879","display_name":"Le Jia","orcid":"https://orcid.org/0000-0002-5656-1339"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Le Jia","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0002-5656-1339","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Jing Zhang","orcid":"https://orcid.org/0000-0003-0788-1827"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jing Zhang","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-0788-1827","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100412395","display_name":"Gang Liu","orcid":"https://orcid.org/0000-0001-7636-7712"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Gang Liu","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0001-7636-7712","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0714876,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"74","issue":null,"first_page":"1","last_page":"10"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9976999759674072,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/magnetometer","display_name":"Magnetometer","score":0.8270386457443237},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.6508966684341431},{"id":"https://openalex.org/keywords/optical-pumping","display_name":"Optical pumping","score":0.5905276536941528},{"id":"https://openalex.org/keywords/in-situ","display_name":"In situ","score":0.5725176334381104},{"id":"https://openalex.org/keywords/absorption","display_name":"Absorption (acoustics)","score":0.5713126063346863},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.5202701687812805},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.5088639259338379},{"id":"https://openalex.org/keywords/optoelectronics","display_name":"Optoelectronics","score":0.45818793773651123},{"id":"https://openalex.org/keywords/atom-optics","display_name":"Atom optics","score":0.43727877736091614},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.2642698884010315},{"id":"https://openalex.org/keywords/laser","display_name":"Laser","score":0.2311684787273407},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.18409931659698486}],"concepts":[{"id":"https://openalex.org/C153946474","wikidata":"https://www.wikidata.org/wiki/Q333921","display_name":"Magnetometer","level":3,"score":0.8270386457443237},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6508966684341431},{"id":"https://openalex.org/C148651041","wikidata":"https://www.wikidata.org/wiki/Q2027473","display_name":"Optical pumping","level":3,"score":0.5905276536941528},{"id":"https://openalex.org/C2777822432","wikidata":"https://www.wikidata.org/wiki/Q216681","display_name":"In situ","level":2,"score":0.5725176334381104},{"id":"https://openalex.org/C125287762","wikidata":"https://www.wikidata.org/wiki/Q1758948","display_name":"Absorption (acoustics)","level":2,"score":0.5713126063346863},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.5202701687812805},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.5088639259338379},{"id":"https://openalex.org/C49040817","wikidata":"https://www.wikidata.org/wiki/Q193091","display_name":"Optoelectronics","level":1,"score":0.45818793773651123},{"id":"https://openalex.org/C2775929963","wikidata":"https://www.wikidata.org/wiki/Q245987","display_name":"Atom optics","level":2,"score":0.43727877736091614},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.2642698884010315},{"id":"https://openalex.org/C520434653","wikidata":"https://www.wikidata.org/wiki/Q38867","display_name":"Laser","level":2,"score":0.2311684787273407},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18409931659698486},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2025.3571111","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2025.3571111","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7099999785423279,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":36,"referenced_works":["https://openalex.org/W2134542170","https://openalex.org/W2473628221","https://openalex.org/W2498294865","https://openalex.org/W2766250057","https://openalex.org/W2791548393","https://openalex.org/W2885507818","https://openalex.org/W2898226994","https://openalex.org/W2941472979","https://openalex.org/W2967267902","https://openalex.org/W3006672642","https://openalex.org/W3013369514","https://openalex.org/W3041034016","https://openalex.org/W3097132226","https://openalex.org/W3159185677","https://openalex.org/W3197871634","https://openalex.org/W3201966318","https://openalex.org/W3204845320","https://openalex.org/W3204881247","https://openalex.org/W3213745067","https://openalex.org/W4210251548","https://openalex.org/W4210461362","https://openalex.org/W4293199254","https://openalex.org/W4293254539","https://openalex.org/W4321014800","https://openalex.org/W4362720569","https://openalex.org/W4366334171","https://openalex.org/W4367359654","https://openalex.org/W4368371729","https://openalex.org/W4377968968","https://openalex.org/W4385578882","https://openalex.org/W4388505122","https://openalex.org/W4389160433","https://openalex.org/W4389494908","https://openalex.org/W4397020964","https://openalex.org/W4406208333","https://openalex.org/W4407942194"],"related_works":["https://openalex.org/W2074940407","https://openalex.org/W2035596186","https://openalex.org/W2885295284","https://openalex.org/W2398658113","https://openalex.org/W309521798","https://openalex.org/W1502875874","https://openalex.org/W2546229752","https://openalex.org/W3200811804","https://openalex.org/W2012010059","https://openalex.org/W4403723212"],"abstract_inverted_index":{"Optically":[0],"Pumped":[1],"Magnetometer":[2],"(OPM)":[3],"is":[4],"an":[5,45],"emerging":[6],"non-invasive":[7],"biological":[8],"magnetic":[9,28,75],"imaging":[10],"sensor.":[11],"The":[12],"vapor":[13,42],"cell,":[14],"its":[15],"core":[16],"component,":[17],"requires":[18],"stable":[19],"temperature":[20,37,55,64,82,98,116,120],"control":[21,83,99,121],"to":[22],"achieve":[23],"ultra-high":[24],"sensitivity":[25,141],"in":[26,88],"weak":[27],"field":[29],"detection.":[30],"This":[31,77],"paper":[32],"presents":[33],"a":[34,85],"full-time,":[35],"magnetic-field-free":[36],"measurement":[38,65,89],"scheme":[39],"for":[40],"atomic":[41],"cells,":[43],"employing":[44],"light":[46,51,62,104,135],"absorption":[47,63,136],"model":[48,66,78],"that":[49],"converts":[50],"intensity":[52],"variations":[53],"into":[54],"readings.":[56],"First,":[57],"we":[58,92],"enhance":[59],"the":[60,69,97,139],"conventional":[61],"by":[67,142],"incorporating":[68],"influences":[70],"from":[71],"static":[72],"and":[73,95,106],"modulated":[74],"fields.":[76],"modification":[79],"enabled":[80],"full-time":[81],"achieving":[84],"0.72\u00b0C":[86],"reduction":[87],"error.":[90],"Subsequently,":[91],"experimentally":[93],"quantify":[94],"analyze":[96],"performance":[100,122],"under":[101],"different":[102],"incident":[103],"intensities":[105],"across":[107],"various":[108],"OPM":[109],"configurations.":[110],"Furthermore,":[111],"cross-validation":[112],"with":[113,133],"platinum":[114,130],"resistance":[115,131],"measurements":[117],"demonstrates":[118],"comparable":[119],"of":[123],"our":[124,134],"proposed":[125],"method.":[126],"Most":[127],"importantly,":[128],"replacing":[129],"sensors":[132],"method":[137],"enhances":[138],"OPM\u2019s":[140],"2.83":[143],"fT/\u221aHz.":[144]},"counts_by_year":[],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
