{"id":"https://openalex.org/W4409683773","doi":"https://doi.org/10.1109/tim.2025.3555701","title":"A Dynamic High-Fidelity Equivalent Circuit Phantom for Intracardiac Communication in Pacemaker Indications","display_name":"A Dynamic High-Fidelity Equivalent Circuit Phantom for Intracardiac Communication in Pacemaker Indications","publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W4409683773","doi":"https://doi.org/10.1109/tim.2025.3555701"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2025.3555701","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2025.3555701","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100759526","display_name":"Dongming Li","orcid":"https://orcid.org/0000-0001-9102-1787"},"institutions":[{"id":"https://openalex.org/I80947539","display_name":"Fuzhou University","ror":"https://ror.org/011xvna82","country_code":"CN","type":"education","lineage":["https://openalex.org/I80947539"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Dongming Li","raw_affiliation_strings":["College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, China"],"raw_orcid":"https://orcid.org/0000-0001-9102-1787","affiliations":[{"raw_affiliation_string":"College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, China","institution_ids":["https://openalex.org/I80947539"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Jiamei Wang","orcid":"https://orcid.org/0009-0003-2168-7729"},"institutions":[{"id":"https://openalex.org/I80947539","display_name":"Fuzhou University","ror":"https://ror.org/011xvna82","country_code":"CN","type":"education","lineage":["https://openalex.org/I80947539"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiamei Wang","raw_affiliation_strings":["College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China"],"raw_orcid":"https://orcid.org/0009-0003-2168-7729","affiliations":[{"raw_affiliation_string":"College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China","institution_ids":["https://openalex.org/I80947539"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5114686101","display_name":"Han Wang","orcid":"https://orcid.org/0009-0007-2747-7625"},"institutions":[{"id":"https://openalex.org/I80947539","display_name":"Fuzhou University","ror":"https://ror.org/011xvna82","country_code":"CN","type":"education","lineage":["https://openalex.org/I80947539"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Han Wang","raw_affiliation_strings":["College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China"],"raw_orcid":"https://orcid.org/0009-0007-2747-7625","affiliations":[{"raw_affiliation_string":"College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China","institution_ids":["https://openalex.org/I80947539"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108216429","display_name":"Xiaoguo Huang","orcid":null},"institutions":[{"id":"https://openalex.org/I80947539","display_name":"Fuzhou University","ror":"https://ror.org/011xvna82","country_code":"CN","type":"education","lineage":["https://openalex.org/I80947539"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaojiang Huang","raw_affiliation_strings":["College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China"],"raw_orcid":"https://orcid.org/0009-0005-3418-3647","affiliations":[{"raw_affiliation_string":"College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China","institution_ids":["https://openalex.org/I80947539"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5104076351","display_name":"Jiejie Yang","orcid":"https://orcid.org/0009-0002-6380-4586"},"institutions":[{"id":"https://openalex.org/I80947539","display_name":"Fuzhou University","ror":"https://ror.org/011xvna82","country_code":"CN","type":"education","lineage":["https://openalex.org/I80947539"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiejie Yang","raw_affiliation_strings":["College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China"],"raw_orcid":"https://orcid.org/0009-0002-6380-4586","affiliations":[{"raw_affiliation_string":"College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China","institution_ids":["https://openalex.org/I80947539"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008053134","display_name":"Yueming Gao","orcid":"https://orcid.org/0000-0002-0197-6043"},"institutions":[{"id":"https://openalex.org/I80947539","display_name":"Fuzhou University","ror":"https://ror.org/011xvna82","country_code":"CN","type":"education","lineage":["https://openalex.org/I80947539"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yueming Gao","raw_affiliation_strings":["College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China"],"raw_orcid":"https://orcid.org/0000-0002-0197-6043","affiliations":[{"raw_affiliation_string":"College of Physical and Information Engineering and the International Joint Laboratory on Health Intelligent Monitoring Systems, Fuzhou University, Fuzhou, Fujian, China","institution_ids":["https://openalex.org/I80947539"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072173302","display_name":"Hung-Chun Li","orcid":null},"institutions":[{"id":"https://openalex.org/I4210165204","display_name":"Zhuhai Institute of Advanced Technology","ror":"https://ror.org/05r1mzq61","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210145761","https://openalex.org/I4210165204"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hung-Chun Li","raw_affiliation_strings":["Joint Laboratory, Zhuhai UM Science and Technology Research Institute, Lingyange Semiconductor Inc., Zhuhai, China","Joint Laboratory of Zhuhai UM Science and Technology Research Institute-Lingyange Semiconductor Incorporated, Zhuhai, China"],"raw_orcid":"https://orcid.org/0009-0009-1062-9631","affiliations":[{"raw_affiliation_string":"Joint Laboratory, Zhuhai UM Science and Technology Research Institute, Lingyange Semiconductor Inc., Zhuhai, China","institution_ids":["https://openalex.org/I4210165204"]},{"raw_affiliation_string":"Joint Laboratory of Zhuhai UM Science and Technology Research Institute-Lingyange Semiconductor Incorporated, Zhuhai, China","institution_ids":["https://openalex.org/I4210165204"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037922594","display_name":"Mang I Vai","orcid":"https://orcid.org/0000-0003-0663-0049"},"institutions":[{"id":"https://openalex.org/I117023288","display_name":"Analog Devices (United States)","ror":"https://ror.org/01545pm61","country_code":"US","type":"company","lineage":["https://openalex.org/I117023288"]},{"id":"https://openalex.org/I204512498","display_name":"University of Macau","ror":"https://ror.org/01r4q9n85","country_code":"MO","type":"education","lineage":["https://openalex.org/I204512498"]}],"countries":["MO","US"],"is_corresponding":false,"raw_author_name":"Mang I Vai","raw_affiliation_strings":["State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Macau, China","State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Taipa, MO, China"],"raw_orcid":"https://orcid.org/0000-0003-0663-0049","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Macau, China","institution_ids":["https://openalex.org/I204512498"]},{"raw_affiliation_string":"State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Taipa, MO, China","institution_ids":["https://openalex.org/I117023288","https://openalex.org/I204512498"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048442222","display_name":"Sio Hang Pun","orcid":"https://orcid.org/0000-0002-8648-2092"},"institutions":[{"id":"https://openalex.org/I117023288","display_name":"Analog Devices (United States)","ror":"https://ror.org/01545pm61","country_code":"US","type":"company","lineage":["https://openalex.org/I117023288"]},{"id":"https://openalex.org/I204512498","display_name":"University of Macau","ror":"https://ror.org/01r4q9n85","country_code":"MO","type":"education","lineage":["https://openalex.org/I204512498"]}],"countries":["MO","US"],"is_corresponding":false,"raw_author_name":"Sio Hang Pun","raw_affiliation_strings":["State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Macau, China","State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Taipa, MO, China"],"raw_orcid":"https://orcid.org/0000-0002-8648-2092","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Macau, China","institution_ids":["https://openalex.org/I204512498"]},{"raw_affiliation_string":"State Key Laboratory of Analog and Mixed-Signal VLSI, University of Macau, Taipa, MO, China","institution_ids":["https://openalex.org/I117023288","https://openalex.org/I204512498"]}]}],"institutions":[],"countries_distinct_count":3,"institutions_distinct_count":9,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.0311,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.76068524,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":"74","issue":null,"first_page":"1","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9825000166893005,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9825000166893005,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11601","display_name":"Neuroscience and Neural Engineering","score":0.974399983882904,"subfield":{"id":"https://openalex.org/subfields/2804","display_name":"Cellular and Molecular Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9692999720573425,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/imaging-phantom","display_name":"Imaging phantom","score":0.7579047679901123},{"id":"https://openalex.org/keywords/intracardiac-injection","display_name":"Intracardiac injection","score":0.6523497700691223},{"id":"https://openalex.org/keywords/fidelity","display_name":"Fidelity","score":0.48226791620254517},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.43295544385910034},{"id":"https://openalex.org/keywords/rlc-circuit","display_name":"RLC circuit","score":0.42209935188293457},{"id":"https://openalex.org/keywords/equivalent-circuit","display_name":"Equivalent circuit","score":0.42174577713012695},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.40365272760391235},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.3955283761024475},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3828577399253845},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.3026287257671356},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27771320939064026},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.20760700106620789},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.1876179575920105},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.14324238896369934},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.13276517391204834}],"concepts":[{"id":"https://openalex.org/C104293457","wikidata":"https://www.wikidata.org/wiki/Q28324852","display_name":"Imaging phantom","level":2,"score":0.7579047679901123},{"id":"https://openalex.org/C80093799","wikidata":"https://www.wikidata.org/wiki/Q366155","display_name":"Intracardiac injection","level":2,"score":0.6523497700691223},{"id":"https://openalex.org/C2776459999","wikidata":"https://www.wikidata.org/wiki/Q2119376","display_name":"Fidelity","level":2,"score":0.48226791620254517},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.43295544385910034},{"id":"https://openalex.org/C89880566","wikidata":"https://www.wikidata.org/wiki/Q323477","display_name":"RLC circuit","level":4,"score":0.42209935188293457},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.42174577713012695},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.40365272760391235},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3955283761024475},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3828577399253845},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3026287257671356},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27771320939064026},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.20760700106620789},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.1876179575920105},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.14324238896369934},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.13276517391204834},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2025.3555701","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2025.3555701","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2352098996","display_name":null,"funder_award_id":"62371136","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G3747472756","display_name":null,"funder_award_id":"CP-031-2022","funder_id":"https://openalex.org/F4320307797","funder_display_name":"National Semiconductor"},{"id":"https://openalex.org/G5354978054","display_name":null,"funder_award_id":"CP-017-2022","funder_id":"https://openalex.org/F4320307797","funder_display_name":"National Semiconductor"},{"id":"https://openalex.org/G7457740152","display_name":null,"funder_award_id":"2023J01401","funder_id":"https://openalex.org/F4320321878","funder_display_name":"Natural Science Foundation of Fujian Province"},{"id":"https://openalex.org/G8727641306","display_name":null,"funder_award_id":"2022YFE0115500","funder_id":"https://openalex.org/F4320335777","funder_display_name":"National Key Research and Development Program of China"}],"funders":[{"id":"https://openalex.org/F4320307797","display_name":"National Semiconductor","ror":"https://ror.org/03vsmv677"},{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320321878","display_name":"Natural Science Foundation of Fujian Province","ror":null},{"id":"https://openalex.org/F4320335777","display_name":"National Key Research and Development Program of China","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":39,"referenced_works":["https://openalex.org/W1937152484","https://openalex.org/W1992533865","https://openalex.org/W2051726781","https://openalex.org/W2069472142","https://openalex.org/W2073420794","https://openalex.org/W2087235720","https://openalex.org/W2100663440","https://openalex.org/W2112412365","https://openalex.org/W2116676468","https://openalex.org/W2133556882","https://openalex.org/W2137011645","https://openalex.org/W2151484914","https://openalex.org/W2153599313","https://openalex.org/W2157815735","https://openalex.org/W2169868043","https://openalex.org/W2288438387","https://openalex.org/W2316559967","https://openalex.org/W2790712606","https://openalex.org/W2898677713","https://openalex.org/W2902136392","https://openalex.org/W2903935041","https://openalex.org/W2908061638","https://openalex.org/W2908775325","https://openalex.org/W2909420799","https://openalex.org/W2914239489","https://openalex.org/W2962423504","https://openalex.org/W2996087529","https://openalex.org/W3012382621","https://openalex.org/W3013682569","https://openalex.org/W3111426669","https://openalex.org/W3135691426","https://openalex.org/W4237384596","https://openalex.org/W4282562746","https://openalex.org/W4282843412","https://openalex.org/W4312561022","https://openalex.org/W4377140679","https://openalex.org/W4391454329","https://openalex.org/W4399230551","https://openalex.org/W6722690732"],"related_works":["https://openalex.org/W2400564179","https://openalex.org/W4206905980","https://openalex.org/W2350915185","https://openalex.org/W1964632492","https://openalex.org/W2356478842","https://openalex.org/W4242170870","https://openalex.org/W2017701310","https://openalex.org/W2136950386","https://openalex.org/W2327142020","https://openalex.org/W4313018643"],"abstract_inverted_index":{"Conductive":[0],"Intracardiac":[1],"Communication":[2],"(CIC)":[3],"is":[4,55,77,108,146],"an":[5],"essential":[6],"approach":[7],"for":[8,21,57,115,221,246],"achieving":[9],"multi-chamber":[10,60,260],"pacing":[11,61,117],"in":[12,163,188],"leadless":[13,259],"pacemakers":[14],"(LCPs),":[15],"significantly":[16],"enhancing":[17,58],"the":[18,27,30,37,43,59,68,93,126,138,150,153,160,164,194,198,213,222,226,247,254],"therapeutic":[19],"outcomes":[20],"conditions":[22],"such":[23],"as":[24],"bradycardia.":[25],"However,":[26],"characteristics":[28,114,200],"of":[29,63,136,152,182,201,225,249,258],"intracardiac":[31,250],"channel":[32,48,75,113,199,233],"are":[33,169],"profoundly":[34],"affected":[35],"by":[36],"heart\u2019s":[38],"rhythmic":[39],"contractions.":[40],"Accurately":[41],"understanding":[42],"dynamic":[44,131],"transmission":[45],"mechanisms":[46],"and":[47,74,166,173,191,203,242,256],"parameters":[49],"under":[50,142],"various":[51,116,143],"cardiac":[52,71,139],"pathological":[53],"states":[54],"crucial":[56],"functionality":[62],"LCPs.":[64],"In":[65],"this":[66,101],"paper,":[67],"relationship":[69],"between":[70],"chamber":[72],"volume":[73],"impedance":[76,94],"mapped":[78],"based":[79,211],"on":[80,212],"electrocardiogram":[81],"data.":[82],"This":[83],"mapping":[84],"enables":[85],"precise,":[86],"real-time":[87],"adjustments":[88],"to":[89,110,125,148],"variable":[90],"impedance,":[91],"simulating":[92,137],"changes":[95],"occurring":[96],"with":[97,176],"each":[98],"heartbeat.":[99],"Through":[100,186],"approach,":[102],"a":[103,121,130,177,239],"time-frequency":[104],"equivalent":[105],"circuit":[106,154,195],"phantom":[107,237],"proposed":[109,236],"accurately":[111],"simulate":[112],"indications":[118],"(PIs).":[119],"Utilizing":[120],"quasi-dual-pump":[122],"structural":[123],"analogy":[124],"heart,":[127],"we":[128],"designed":[129],"experimental":[132,244],"measurement":[133,216],"platform":[134],"capable":[135],"beating":[140],"process":[141],"PIs,":[144],"which":[145],"employed":[147],"validate":[149],"accuracy":[151],"phantom.":[155],"The":[156,207,235],"results":[157,217],"demonstrate":[158],"that":[159],"correlation":[161],"coefficients":[162],"frequency":[165,190],"time":[167,178,192,214],"domains":[168],"greater":[170],"than":[171,184],"0.9432":[172],"0.9150,":[174],"respectively,":[175],"domain":[179,215],"consistency":[180],"coefficient":[181],"less":[183],"3.25.":[185],"cross-validation":[187],"both":[189],"domains,":[193],"effectively":[196],"simulates":[197],"normal":[202],"pacemaker":[204,261],"indication":[205],"hearts.":[206],"empirical":[208],"formula":[209],"established":[210],"can":[218],"be":[219],"utilized":[220],"rapid":[223],"estimation":[224],"right":[227,230],"atrial":[228],"(RA)-":[229],"ventricle":[231],"(RV)":[232],"characteristics.":[234],"offers":[238],"highly":[240],"accurate":[241],"reproducible":[243],"method":[245],"design":[248],"communication":[251],"transceivers,":[252],"advancing":[253],"development":[255],"validation":[257],"systems.":[262]},"counts_by_year":[{"year":2025,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
