{"id":"https://openalex.org/W4402125007","doi":"https://doi.org/10.1109/tim.2024.3453341","title":"Removal of Motion Artifacts in PPG Signals Based on the CEEMDAN-MPE and VS_LMS Adaptive Filter","display_name":"Removal of Motion Artifacts in PPG Signals Based on the CEEMDAN-MPE and VS_LMS Adaptive Filter","publication_year":2024,"publication_date":"2024-01-01","ids":{"openalex":"https://openalex.org/W4402125007","doi":"https://doi.org/10.1109/tim.2024.3453341"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2024.3453341","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2024.3453341","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5068363983","display_name":"Linjia Zhang","orcid":"https://orcid.org/0009-0009-0866-1675"},"institutions":[{"id":"https://openalex.org/I24201400","display_name":"Chengdu University of Information Technology","ror":"https://ror.org/01yxwrh59","country_code":"CN","type":"education","lineage":["https://openalex.org/I24201400"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Linjia Zhang","raw_affiliation_strings":["Department of Electrical and Electronic Engineering and the Key Laboratory of Biological Effect of Physical Field and Instrument, Chengdu University of Information Technology, Chengdu, China"],"raw_orcid":"https://orcid.org/0009-0009-0866-1675","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering and the Key Laboratory of Biological Effect of Physical Field and Instrument, Chengdu University of Information Technology, Chengdu, China","institution_ids":["https://openalex.org/I24201400"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089360079","display_name":"Xiaomin Yu","orcid":"https://orcid.org/0000-0001-8006-6111"},"institutions":[{"id":"https://openalex.org/I24201400","display_name":"Chengdu University of Information Technology","ror":"https://ror.org/01yxwrh59","country_code":"CN","type":"education","lineage":["https://openalex.org/I24201400"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaomin Yu","raw_affiliation_strings":["Department of Electrical and Electronic Engineering and the Key Laboratory of Biological Effect of Physical Field and Instrument, Chengdu University of Information Technology, Chengdu, China"],"raw_orcid":"https://orcid.org/0000-0001-8006-6111","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering and the Key Laboratory of Biological Effect of Physical Field and Instrument, Chengdu University of Information Technology, Chengdu, China","institution_ids":["https://openalex.org/I24201400"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026793138","display_name":"Huikai Xie","orcid":"https://orcid.org/0000-0002-8393-0021"},"institutions":[{"id":"https://openalex.org/I125839683","display_name":"Beijing Institute of Technology","ror":"https://ror.org/01skt4w74","country_code":"CN","type":"education","lineage":["https://openalex.org/I125839683","https://openalex.org/I890469752"]},{"id":"https://openalex.org/I4210089056","display_name":"Beijing Microelectronics Technology Institute","ror":"https://ror.org/007y7ej30","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210089056"]},{"id":"https://openalex.org/I4210119392","display_name":"Institute of Microelectronics","ror":"https://ror.org/02s6gs133","country_code":"CN","type":"facility","lineage":["https://openalex.org/I19820366","https://openalex.org/I4210119392"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Huikai Xie","raw_affiliation_strings":["Chongqing Institute of Microelectronics and Microsystems, Beijing Institute of Technology, Chongqing, China"],"raw_orcid":"https://orcid.org/0000-0002-8393-0021","affiliations":[{"raw_affiliation_string":"Chongqing Institute of Microelectronics and Microsystems, Beijing Institute of Technology, Chongqing, China","institution_ids":["https://openalex.org/I125839683","https://openalex.org/I4210089056","https://openalex.org/I4210119392"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102138314","display_name":"Jian Lin","orcid":"https://orcid.org/0009-0006-2820-8219"},"institutions":[{"id":"https://openalex.org/I4210118397","display_name":"Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital","ror":"https://ror.org/01qh26a66","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210118397"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jian Lin","raw_affiliation_strings":["Sichuan Academy of Medical Science and Sichuan Provincial People&#x00C3;s Hospital, Chengdu, China"],"raw_orcid":"https://orcid.org/0009-0006-2820-8219","affiliations":[{"raw_affiliation_string":"Sichuan Academy of Medical Science and Sichuan Provincial People&#x00C3;s Hospital, Chengdu, China","institution_ids":["https://openalex.org/I4210118397"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082333821","display_name":"Zhengxian Wang","orcid":"https://orcid.org/0009-0007-2340-8788"},"institutions":[{"id":"https://openalex.org/I24201400","display_name":"Chengdu University of Information Technology","ror":"https://ror.org/01yxwrh59","country_code":"CN","type":"education","lineage":["https://openalex.org/I24201400"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhengxian Wang","raw_affiliation_strings":["Department of Electrical and Electronic Engineering and the Key Laboratory of Biological Effect of Physical Field and Instrument, Chengdu University of Information Technology, Chengdu, China"],"raw_orcid":"https://orcid.org/0009-0007-2340-8788","affiliations":[{"raw_affiliation_string":"Department of Electrical and Electronic Engineering and the Key Laboratory of Biological Effect of Physical Field and Instrument, Chengdu University of Information Technology, Chengdu, China","institution_ids":["https://openalex.org/I24201400"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.8876,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.68833098,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"73","issue":null,"first_page":"1","last_page":"10"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12419","display_name":"Phonocardiography and Auscultation Techniques","score":0.9850999712944031,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9824000000953674,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/adaptive-filter","display_name":"Adaptive filter","score":0.7094734311103821},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.5102710723876953},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5001029968261719},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.48778754472732544},{"id":"https://openalex.org/keywords/filtering-theory","display_name":"Filtering theory","score":0.4842681288719177},{"id":"https://openalex.org/keywords/motion","display_name":"Motion (physics)","score":0.45416978001594543},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.4359458386898041},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.3461729884147644},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.19723737239837646},{"id":"https://openalex.org/keywords/algorithm","display_name":"Algorithm","score":0.10858488082885742}],"concepts":[{"id":"https://openalex.org/C102248274","wikidata":"https://www.wikidata.org/wiki/Q168388","display_name":"Adaptive filter","level":2,"score":0.7094734311103821},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.5102710723876953},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5001029968261719},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.48778754472732544},{"id":"https://openalex.org/C2988922011","wikidata":"https://www.wikidata.org/wiki/Q5449244","display_name":"Filtering theory","level":2,"score":0.4842681288719177},{"id":"https://openalex.org/C104114177","wikidata":"https://www.wikidata.org/wiki/Q79782","display_name":"Motion (physics)","level":2,"score":0.45416978001594543},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.4359458386898041},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3461729884147644},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.19723737239837646},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.10858488082885742}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2024.3453341","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2024.3453341","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.44999998807907104,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"}],"awards":[{"id":"https://openalex.org/G5877178936","display_name":null,"funder_award_id":"2019YJ0317","funder_id":"https://openalex.org/F4320337504","funder_display_name":"Research and Development"},{"id":"https://openalex.org/G8138893607","display_name":null,"funder_award_id":"2023YFS0468","funder_id":"https://openalex.org/F4320337504","funder_display_name":"Research and Development"}],"funders":[{"id":"https://openalex.org/F4320337504","display_name":"Research and Development","ror":"https://ror.org/027s68j25"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":31,"referenced_works":["https://openalex.org/W87496662","https://openalex.org/W1965789387","https://openalex.org/W1998104979","https://openalex.org/W2021285056","https://openalex.org/W2030134993","https://openalex.org/W2083872334","https://openalex.org/W2085953673","https://openalex.org/W2101394537","https://openalex.org/W2103675325","https://openalex.org/W2107994016","https://openalex.org/W2117987876","https://openalex.org/W2120495964","https://openalex.org/W2130007238","https://openalex.org/W2143428794","https://openalex.org/W2146587431","https://openalex.org/W2159674655","https://openalex.org/W2166722852","https://openalex.org/W2171380770","https://openalex.org/W2294747933","https://openalex.org/W2552949171","https://openalex.org/W2626247988","https://openalex.org/W2770618476","https://openalex.org/W2785226973","https://openalex.org/W2911012145","https://openalex.org/W2996358218","https://openalex.org/W3080956775","https://openalex.org/W3099855885","https://openalex.org/W3172928837","https://openalex.org/W4223649787","https://openalex.org/W4225468936","https://openalex.org/W4317802340"],"related_works":["https://openalex.org/W4386051551","https://openalex.org/W1500438404","https://openalex.org/W1501804233","https://openalex.org/W1976504964","https://openalex.org/W2039473711","https://openalex.org/W2112857436","https://openalex.org/W2142537705","https://openalex.org/W2166470059","https://openalex.org/W1999667596","https://openalex.org/W1848664427"],"abstract_inverted_index":{"The":[0,176,218],"performance":[1],"of":[2,29,36,167,206,230],"a":[3,37,54,68,158,163],"wearable":[4],"oximeter":[5],"based":[6,66],"on":[7,67],"processing":[8],"photoplethysmographic":[9],"(PPG)":[10],"signals":[11,63,151,243],"is":[12,43,49,64,106,124],"largely":[13],"affected":[14],"by":[15],"the":[16,26,34,46,75,97,102,112,118,143,149,172,204,207,222,227],"motion":[17,21],"artifacts":[18],"(MAs)":[19],"during":[20,186,194,244],"episodes.":[22],"To":[23],"effectively":[24],"improve":[25,226],"estimation":[27,228],"accuracy":[28,229],"arterial":[30],"oxygen":[31],"saturation":[32],"(SpO2),":[33],"quality":[35],"reference":[38,70,98,121,173],"noise":[39,71,99,122],"signal":[40,72,78,123],"before":[41],"it":[42],"applied":[44,125],"to":[45,94,126,131,171],"adaptive":[47,129],"filtering":[48],"vital.":[50],"In":[51],"this":[52],"study,":[53],"novel":[55],"method":[56],"for":[57,85,210,236],"reducing":[58,136,211],"MAs":[59],"in":[60,135],"corrupted":[61,76,114],"PPG":[62,77,115,150,242],"proposed,":[65],"synthetic":[69,120],"generated":[73],"from":[74,148,157],"itself":[79],"and":[80,101,156,181,190,193,199,213,232],"an":[81],"efficient":[82],"adapter":[83],"filter":[84],"MA":[86,113,137,212],"reduction.":[87],"Specifically,":[88],"three":[89],"methods":[90],"are":[91],"first":[92],"used":[93],"individually":[95],"generate":[96],"signals,":[100],"most":[103],"suitable":[104],"one":[105],"selected":[107,119],"using":[108,153],"correlation":[109,165],"analysis":[110],"with":[111],"signal.":[116],"Thus,":[117],"four":[127],"different":[128],"filters":[130],"assess":[132],"their":[133],"effectiveness":[134],"noise.":[138],"Experimental":[139],"results":[140],"showed":[141],"that":[142,221,240],"estimated":[144],"SpO2":[145,174,216,231],"values,":[146],"derived":[147],"acquired":[152],"self-designed":[154],"equipment":[155],"publicly":[159],"online":[160],"dataset,":[161],"had":[162],"Pearson":[164],"coefficient":[166],"0.9775":[168],"when":[169],"compared":[170],"values.":[175,217],"mean":[177,182],"absolute":[178],"error":[179,184],"(MAE)":[180],"squared":[183],"(mse)":[185],"walking":[187],"were":[188,197],"0.5721":[189],"0.4615,":[191],"respectively,":[192,201],"jogging,":[195],"they":[196],"0.7231":[198],"0.5202,":[200],"which":[202],"demonstrated":[203],"efficacy":[205],"proposed":[208,223],"scheme":[209,224],"accurately":[214],"estimating":[215],"study":[219],"shows":[220],"can":[225],"may":[233],"be":[234],"suited":[235],"modern":[237],"pulse":[238],"oximeters":[239],"utilize":[241],"motion.":[245]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":6}],"updated_date":"2026-07-22T07:51:19.307946","created_date":"2025-10-10T00:00:00"}
