{"id":"https://openalex.org/W4400878144","doi":"https://doi.org/10.1109/tim.2024.3432142","title":"Design and Characterization of a Combined Low-Power Voltage and Current Instrument Transformer for Low-Voltage Applications","display_name":"Design and Characterization of a Combined Low-Power Voltage and Current Instrument Transformer for Low-Voltage Applications","publication_year":2024,"publication_date":"2024-01-01","ids":{"openalex":"https://openalex.org/W4400878144","doi":"https://doi.org/10.1109/tim.2024.3432142"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2024.3432142","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2024.3432142","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://re.public.polimi.it/bitstream/11311/1275989/6/Paper%20sent.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5080539645","display_name":"Youpeng Huangfu","orcid":"https://orcid.org/0000-0003-0921-6951"},"institutions":[{"id":"https://openalex.org/I4391768273","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":"https://ror.org/03kd9rr37","country_code":null,"type":"facility","lineage":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]},{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Youpeng Huangfu","raw_affiliation_strings":["State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi&#x2019;an Jiaotong University, Xi&#x2019;an, China"],"raw_orcid":"https://orcid.org/0000-0003-0921-6951","affiliations":[{"raw_affiliation_string":"State Key Laboratory of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi&#x2019;an Jiaotong University, Xi&#x2019;an, China","institution_ids":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5001972308","display_name":"Marco Faifer","orcid":"https://orcid.org/0000-0002-8777-5444"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Marco Faifer","raw_affiliation_strings":["Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy"],"raw_orcid":"https://orcid.org/0000-0002-8777-5444","affiliations":[{"raw_affiliation_string":"Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017740145","display_name":"Roberto Ottoboni","orcid":"https://orcid.org/0000-0002-5371-1346"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Roberto Ottoboni","raw_affiliation_strings":["Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy"],"raw_orcid":"https://orcid.org/0000-0002-5371-1346","affiliations":[{"raw_affiliation_string":"Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5003675815","display_name":"Sergio Toscani","orcid":"https://orcid.org/0000-0003-2317-5818"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Sergio Toscani","raw_affiliation_strings":["Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy"],"raw_orcid":"https://orcid.org/0000-0003-2317-5818","affiliations":[{"raw_affiliation_string":"Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.0154,"has_fulltext":true,"cited_by_count":10,"citation_normalized_percentile":{"value":0.86458412,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"73","issue":null,"first_page":"1","last_page":"10"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9947999715805054,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9947999715805054,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9725000262260437,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9523000121116638,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.6623615026473999},{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.6616814136505127},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5641024708747864},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5538218021392822},{"id":"https://openalex.org/keywords/voltage-optimisation","display_name":"Voltage optimisation","score":0.4631110727787018},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.42674335837364197},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.4201299846172333},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4149632155895233},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3819604516029358},{"id":"https://openalex.org/keywords/switched-mode-power-supply","display_name":"Switched-mode power supply","score":0.36877793073654175}],"concepts":[{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.6623615026473999},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.6616814136505127},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5641024708747864},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5538218021392822},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.4631110727787018},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.42674335837364197},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.4201299846172333},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4149632155895233},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3819604516029358},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.36877793073654175}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tim.2024.3432142","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2024.3432142","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:re.public.polimi.it:11311/1275989","is_oa":true,"landing_page_url":"https://hdl.handle.net/11311/1275989","pdf_url":"https://re.public.polimi.it/bitstream/11311/1275989/6/Paper%20sent.pdf","source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:re.public.polimi.it:11311/1275989","is_oa":true,"landing_page_url":"https://hdl.handle.net/11311/1275989","pdf_url":"https://re.public.polimi.it/bitstream/11311/1275989/6/Paper%20sent.pdf","source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8299999833106995,"id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G6982584056","display_name":null,"funder_award_id":"EIPE24208","funder_id":"https://openalex.org/F4320327040","funder_display_name":"State Key Laboratory of Electrical Insulation and Power Equipment"}],"funders":[{"id":"https://openalex.org/F4320327040","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":null}],"has_content":{"pdf":true,"grobid_xml":false},"content_urls":{"pdf":"https://content.openalex.org/works/W4400878144.pdf"},"referenced_works_count":35,"referenced_works":["https://openalex.org/W2012968878","https://openalex.org/W2034289781","https://openalex.org/W2079071820","https://openalex.org/W2114555874","https://openalex.org/W2127394451","https://openalex.org/W2156002823","https://openalex.org/W2171992165","https://openalex.org/W2194461366","https://openalex.org/W2296077479","https://openalex.org/W2319758096","https://openalex.org/W2576921197","https://openalex.org/W2605195494","https://openalex.org/W2734421138","https://openalex.org/W2751581916","https://openalex.org/W2883547583","https://openalex.org/W2904445663","https://openalex.org/W2931214005","https://openalex.org/W2946671858","https://openalex.org/W2966872289","https://openalex.org/W2984780699","https://openalex.org/W3000343853","https://openalex.org/W3037575284","https://openalex.org/W3047172377","https://openalex.org/W3081869193","https://openalex.org/W3093753235","https://openalex.org/W3120380926","https://openalex.org/W3133706333","https://openalex.org/W3203938210","https://openalex.org/W3217424419","https://openalex.org/W4241853782","https://openalex.org/W4289731790","https://openalex.org/W4294643406","https://openalex.org/W4312355981","https://openalex.org/W4379805690","https://openalex.org/W4385839644"],"related_works":["https://openalex.org/W1561501392","https://openalex.org/W4293087601","https://openalex.org/W2376722172","https://openalex.org/W2906318537","https://openalex.org/W2103067147","https://openalex.org/W2393114038","https://openalex.org/W2375362099","https://openalex.org/W1976160988","https://openalex.org/W4253452958","https://openalex.org/W2124981743"],"abstract_inverted_index":{"Recent":[0],"trends":[1],"in":[2],"smart":[3],"substations":[4],"have":[5],"massively":[6],"motivated":[7],"the":[8,16,32,70,79,84,114,118],"integration":[9],"of":[10,18,34,83,117],"low-power":[11,37],"instrument":[12,41],"transformers":[13],"(LPITs)":[14],"for":[15,31,43,63,78,132,146],"purpose":[17],"metering,":[19],"monitoring,":[20],"protection,":[21],"and":[22,39,55,65,95,128,134,143,153],"control.":[23],"In":[24,49],"this":[25],"article,":[26],"a":[27,35,51,56,141],"novel":[28],"design":[29],"principle":[30],"development":[33],"combined":[36,119,147],"voltage":[38,53,64,85,94,133],"current":[40,66,100,135],"transformer":[42],"low-voltage":[44],"(LV)":[45],"applications":[46],"is":[47,73],"proposed.":[48],"specific,":[50],"capacitive":[52],"divider":[54],"shielded":[57],"Rogowski":[58],"coil":[59],"(RC)":[60],"are":[61],"employed":[62],"measurement,":[67,136],"respectively.":[68,137],"Significantly,":[69],"RC":[71],"shield":[72],"exploited":[74],"as":[75],"an":[76],"electrode":[77],"high-voltage":[80],"(HV)":[81],"capacitance":[82],"divider.":[86],"A":[87,97],"prototype":[88],"featuring":[89],"400":[90],"V":[91],"rated":[92,98],"primary":[93,99],"500":[96],"has":[101,107],"been":[102,108],"developed.":[103],"Subsequently,":[104],"accuracy":[105,130],"characterization":[106],"carried":[109],"out.":[110],"Experimental":[111],"results":[112],"confirm":[113],"full":[115],"compliance":[116],"transducer":[120],"with":[121,150],"IEC":[122],"61":[123],"869":[124],"standards,":[125],"assuring":[126],"0.5":[127],"0.1":[129],"classes":[131],"This":[138],"research":[139],"provides":[140],"compact":[142],"cost-effective":[144],"solution":[145],"LV":[148],"LPITs":[149],"high":[151],"precision":[152],"wide":[154],"dynamic":[155],"range.":[156]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":7},{"year":2024,"cited_by_count":1}],"updated_date":"2026-08-11T07:18:39.950985","created_date":"2025-10-10T00:00:00"}
