{"id":"https://openalex.org/W4393405620","doi":"https://doi.org/10.1109/tim.2024.3383488","title":"Efficient Detection of Series Arc Fault at the Back End of Frequency Converter Using KTDM-Optimized Lightweight Model","display_name":"Efficient Detection of Series Arc Fault at the Back End of Frequency Converter Using KTDM-Optimized Lightweight Model","publication_year":2024,"publication_date":"2024-01-01","ids":{"openalex":"https://openalex.org/W4393405620","doi":"https://doi.org/10.1109/tim.2024.3383488"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2024.3383488","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2024.3383488","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5056870188","display_name":"Zhiyong Wang","orcid":"https://orcid.org/0000-0003-0815-9254"},"institutions":[{"id":"https://openalex.org/I176808543","display_name":"Liaoning Technical University","ror":"https://ror.org/01n2bd587","country_code":"CN","type":"education","lineage":["https://openalex.org/I176808543"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Zhiyong Wang","raw_affiliation_strings":["Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China"],"raw_orcid":"https://orcid.org/0000-0003-0815-9254","affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China","institution_ids":["https://openalex.org/I176808543"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065405247","display_name":"Shigang Tian","orcid":"https://orcid.org/0000-0001-7088-4399"},"institutions":[{"id":"https://openalex.org/I176808543","display_name":"Liaoning Technical University","ror":"https://ror.org/01n2bd587","country_code":"CN","type":"education","lineage":["https://openalex.org/I176808543"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shigang Tian","raw_affiliation_strings":["Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China"],"raw_orcid":"https://orcid.org/0000-0001-7088-4399","affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China","institution_ids":["https://openalex.org/I176808543"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034996982","display_name":"H. Gao","orcid":"https://orcid.org/0000-0002-5466-4510"},"institutions":[{"id":"https://openalex.org/I176808543","display_name":"Liaoning Technical University","ror":"https://ror.org/01n2bd587","country_code":"CN","type":"education","lineage":["https://openalex.org/I176808543"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongxin Gao","raw_affiliation_strings":["Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China"],"raw_orcid":"https://orcid.org/0000-0002-5466-4510","affiliations":[{"raw_affiliation_string":"Faculty of Electrical and Control Engineering, Liaoning Technical University, Huludao, China","institution_ids":["https://openalex.org/I176808543"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5040650687","display_name":"Fengyi Guo","orcid":"https://orcid.org/0000-0002-2785-8109"},"institutions":[{"id":"https://openalex.org/I146620803","display_name":"Wenzhou University","ror":"https://ror.org/020hxh324","country_code":"CN","type":"education","lineage":["https://openalex.org/I146620803"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fengyi Guo","raw_affiliation_strings":["College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China"],"raw_orcid":"https://orcid.org/0000-0002-2785-8109","affiliations":[{"raw_affiliation_string":"College of Electrical and Electronic Engineering, Wenzhou University, Wenzhou, China","institution_ids":["https://openalex.org/I146620803"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5056870188"],"corresponding_institution_ids":["https://openalex.org/I176808543"],"apc_list":null,"apc_paid":null,"fwci":1.6023,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.82868722,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":99},"biblio":{"volume":"73","issue":null,"first_page":"1","last_page":"15"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9794999957084656,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10834","display_name":"Welding Techniques and Residual Stresses","score":0.9458000063896179,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/series","display_name":"Series (stratigraphy)","score":0.6160144805908203},{"id":"https://openalex.org/keywords/arc","display_name":"Arc (geometry)","score":0.5145949125289917},{"id":"https://openalex.org/keywords/fault","display_name":"Fault (geology)","score":0.48847877979278564},{"id":"https://openalex.org/keywords/fault-detection-and-isolation","display_name":"Fault detection and isolation","score":0.4653404951095581},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4297619163990021},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.38430294394493103},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3363964259624481},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.31172531843185425},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.11130890250205994},{"id":"https://openalex.org/keywords/geology","display_name":"Geology","score":0.08599722385406494}],"concepts":[{"id":"https://openalex.org/C143724316","wikidata":"https://www.wikidata.org/wiki/Q312468","display_name":"Series (stratigraphy)","level":2,"score":0.6160144805908203},{"id":"https://openalex.org/C83415579","wikidata":"https://www.wikidata.org/wiki/Q161973","display_name":"Arc (geometry)","level":2,"score":0.5145949125289917},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.48847877979278564},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.4653404951095581},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4297619163990021},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.38430294394493103},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3363964259624481},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.31172531843185425},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.11130890250205994},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.08599722385406494},{"id":"https://openalex.org/C165205528","wikidata":"https://www.wikidata.org/wiki/Q83371","display_name":"Seismology","level":1,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0},{"id":"https://openalex.org/C172707124","wikidata":"https://www.wikidata.org/wiki/Q423488","display_name":"Actuator","level":2,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2024.3383488","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2024.3383488","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4399999976158142,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G8931163074","display_name":null,"funder_award_id":"52077158","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":39,"referenced_works":["https://openalex.org/W1987971958","https://openalex.org/W2187089797","https://openalex.org/W2809624076","https://openalex.org/W2926172260","https://openalex.org/W2951104886","https://openalex.org/W2963140444","https://openalex.org/W2965862774","https://openalex.org/W2995607862","https://openalex.org/W2998423323","https://openalex.org/W3001340915","https://openalex.org/W3017746288","https://openalex.org/W3082299565","https://openalex.org/W3119697583","https://openalex.org/W3121696187","https://openalex.org/W3144184193","https://openalex.org/W3161461318","https://openalex.org/W3164563352","https://openalex.org/W3177367985","https://openalex.org/W3184612210","https://openalex.org/W3205004044","https://openalex.org/W3217631125","https://openalex.org/W4205391559","https://openalex.org/W4213433538","https://openalex.org/W4214687991","https://openalex.org/W4223986110","https://openalex.org/W4225647516","https://openalex.org/W4226068325","https://openalex.org/W4226367113","https://openalex.org/W4295956177","https://openalex.org/W4317038568","https://openalex.org/W4378805016","https://openalex.org/W4386083031","https://openalex.org/W6668990524","https://openalex.org/W6752515464","https://openalex.org/W6753069482","https://openalex.org/W6762718338","https://openalex.org/W6769906912","https://openalex.org/W6776320331","https://openalex.org/W6788034315"],"related_works":["https://openalex.org/W2544839741","https://openalex.org/W2810064750","https://openalex.org/W3036572561","https://openalex.org/W1919101720","https://openalex.org/W2515218844","https://openalex.org/W1885735754","https://openalex.org/W3045564025","https://openalex.org/W1965970232","https://openalex.org/W2033676320","https://openalex.org/W4390822878"],"abstract_inverted_index":{"Series":[0],"arc":[1],"fault":[2],"(SAF)":[3],"is":[4,14],"one":[5],"of":[6,10,25,101,127,161,202],"the":[7,22,45,49,55,72,76,85,99,110,119,124,128,136,145,157,162,166,197,203],"main":[8],"causes":[9],"electrical":[11],"fire.":[12],"There":[13],"no":[15],"effective":[16],"detection":[17,40],"method":[18,92,151],"for":[19],"SAF":[20,31,39,46,56,73,177],"at":[21,48],"back":[23],"end":[24],"frequency":[26],"converter":[27],"(BEFC).":[28],"A":[29],"lightweight":[30,65,90],"identification":[32,57,111,186,209],"model":[33,58,129,168,204],"was":[34,42,59,81,95,106,169],"proposed":[35,96],"and":[36,75,152,155,188,199,211],"an":[37,172],"on-line":[38],"device":[41,174],"developed.":[43],"First,":[44],"experiments":[47],"BEFC":[50],"were":[51,68],"carried":[52],"out.":[53],"Second,":[54],"designed":[60],"based":[61,97],"on":[62,98],"EfficientNet,":[63],"multiple":[64],"modules":[66],"MBConv":[67],"applied":[69],"to":[70,83,108,171,175],"extract":[71],"features,":[74],"global":[77],"average":[78],"pooling":[79],"layer":[80],"used":[82,107],"improve":[84,196],"model\u2019s":[86],"complexity.":[87],"Third,":[88],"a":[89],"design":[91],"KTDM,":[93],"which":[94],"idea":[100],"reducing":[102],"feature":[103,120],"mapping":[104],"redundancy,":[105],"optimize":[109],"model.":[112],"The":[113],"specific":[114],"steps":[115],"include:":[116],"a)":[117],"visualize":[118],"mappings":[121],"output":[122],"from":[123],"convolutional":[125,163],"layers":[126],"by":[130,139,148],"using":[131,140,149],"t-SNE":[132],"algorithm;":[133,142],"2)":[134],"cluster":[135],"visualization":[137],"results":[138,147],"k-means++":[141],"3)":[143],"analyze":[144],"clustering":[146],"elbow":[150],"silhouette":[153],"coefficient,":[154],"determine":[156],"optimal":[158],"channel":[159],"number":[160],"layers.":[164],"Finally,":[165],"optimized":[167],"deployed":[170],"embedded":[173],"detect":[176],"under":[178],"various":[179],"operation":[180],"conditions":[181],"in":[182],"real":[183],"time.":[184],"Both":[185],"accuracy":[187,210],"real-time":[189,200],"performance":[190,201],"meet":[191],"IEC62606":[192],"standard.":[193],"KTDM":[194],"can":[195],"complexity":[198],"without":[205],"obviously":[206],"lowering":[207],"its":[208],"robustness.":[212]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":6},{"year":2024,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}