{"id":"https://openalex.org/W4382677727","doi":"https://doi.org/10.1109/tim.2023.3290988","title":"Co-Surface Three-Electrode Capacitive Sensoring Method for Prestressed Tendon Positioning in Grouted Duct","display_name":"Co-Surface Three-Electrode Capacitive Sensoring Method for Prestressed Tendon Positioning in Grouted Duct","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4382677727","doi":"https://doi.org/10.1109/tim.2023.3290988"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2023.3290988","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2023.3290988","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Wenlong Tao","orcid":"https://orcid.org/0000-0002-2226-1274"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wenlong Tao","raw_affiliation_strings":["School of Automation, Northwestern Polytechnical University, Xi&#x2019;an, China"],"raw_orcid":"https://orcid.org/0000-0002-2226-1274","affiliations":[{"raw_affiliation_string":"School of Automation, Northwestern Polytechnical University, Xi&#x2019;an, China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090653293","display_name":"Yingnan Kang","orcid":"https://orcid.org/0000-0002-1745-9761"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yingnan Kang","raw_affiliation_strings":["School of Automation, Northwestern Polytechnical University, Xi&#x2019;an, China"],"raw_orcid":"https://orcid.org/0000-0002-1745-9761","affiliations":[{"raw_affiliation_string":"School of Automation, Northwestern Polytechnical University, Xi&#x2019;an, China","institution_ids":["https://openalex.org/I17145004"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021812383","display_name":"Nan Li","orcid":"https://orcid.org/0000-0003-3731-1518"},"institutions":[{"id":"https://openalex.org/I17145004","display_name":"Northwestern Polytechnical University","ror":"https://ror.org/01y0j0j86","country_code":"CN","type":"education","lineage":["https://openalex.org/I17145004"]},{"id":"https://openalex.org/I37796252","display_name":"Beijing University of Technology","ror":"https://ror.org/037b1pp87","country_code":"CN","type":"education","lineage":["https://openalex.org/I37796252"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Nan Li","raw_affiliation_strings":["School of Automation, Northwestern Polytechnical University, Xi&#x2019;an, China","Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing University of Technology, Beijing, China"],"raw_orcid":"https://orcid.org/0000-0003-3731-1518","affiliations":[{"raw_affiliation_string":"School of Automation, Northwestern Polytechnical University, Xi&#x2019;an, China","institution_ids":["https://openalex.org/I17145004"]},{"raw_affiliation_string":"Beijing Engineering Research Center of Precision Measurement Technology and Instruments, Beijing University of Technology, Beijing, China","institution_ids":["https://openalex.org/I37796252"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5065658551","display_name":"Hwa Kian Chai","orcid":"https://orcid.org/0000-0002-4153-9155"},"institutions":[{"id":"https://openalex.org/I98677209","display_name":"University of Edinburgh","ror":"https://ror.org/01nrxwf90","country_code":"GB","type":"education","lineage":["https://openalex.org/I98677209"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Hwa Kian Chai","raw_affiliation_strings":["School of Engineering, The University of Edinburgh, Edinburgh, U.K","School of Engineering, The University of Edinburgh, South Bridge, Edinburgh, United Kingdom"],"raw_orcid":"https://orcid.org/0000-0002-4153-9155","affiliations":[{"raw_affiliation_string":"School of Engineering, The University of Edinburgh, Edinburgh, U.K","institution_ids":["https://openalex.org/I98677209"]},{"raw_affiliation_string":"School of Engineering, The University of Edinburgh, South Bridge, Edinburgh, United Kingdom","institution_ids":["https://openalex.org/I98677209"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5044092715","display_name":"Yunjie Yang","orcid":"https://orcid.org/0000-0002-5797-9753"},"institutions":[{"id":"https://openalex.org/I98677209","display_name":"University of Edinburgh","ror":"https://ror.org/01nrxwf90","country_code":"GB","type":"education","lineage":["https://openalex.org/I98677209"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Yunjie Yang","raw_affiliation_strings":["School of Engineering, The University of Edinburgh, Edinburgh, U.K","School of Engineering, The University of Edinburgh, South Bridge, Edinburgh, United Kingdom"],"raw_orcid":"https://orcid.org/0000-0002-5797-9753","affiliations":[{"raw_affiliation_string":"School of Engineering, The University of Edinburgh, Edinburgh, U.K","institution_ids":["https://openalex.org/I98677209"]},{"raw_affiliation_string":"School of Engineering, The University of Edinburgh, South Bridge, Edinburgh, United Kingdom","institution_ids":["https://openalex.org/I98677209"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4016,"has_fulltext":false,"cited_by_count":3,"citation_normalized_percentile":{"value":0.56991176,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":96,"max":97},"biblio":{"volume":"72","issue":null,"first_page":"1","last_page":"10"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10662","display_name":"Ultrasonics and Acoustic Wave Propagation","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.7748407125473022},{"id":"https://openalex.org/keywords/tendon","display_name":"Tendon","score":0.6713182330131531},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.6036049127578735},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5553706884384155},{"id":"https://openalex.org/keywords/duct","display_name":"Duct (anatomy)","score":0.5041433572769165},{"id":"https://openalex.org/keywords/prestressed-concrete","display_name":"Prestressed concrete","score":0.46303945779800415},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.41584789752960205},{"id":"https://openalex.org/keywords/structural-engineering","display_name":"Structural engineering","score":0.41076183319091797},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.37712010741233826},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3397839665412903},{"id":"https://openalex.org/keywords/composite-material","display_name":"Composite material","score":0.30061647295951843},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17760086059570312},{"id":"https://openalex.org/keywords/anatomy","display_name":"Anatomy","score":0.15517258644104004},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.12406614422798157},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.07261848449707031}],"concepts":[{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.7748407125473022},{"id":"https://openalex.org/C2780105995","wikidata":"https://www.wikidata.org/wiki/Q232358","display_name":"Tendon","level":2,"score":0.6713182330131531},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.6036049127578735},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5553706884384155},{"id":"https://openalex.org/C2781212128","wikidata":"https://www.wikidata.org/wiki/Q2256181","display_name":"Duct (anatomy)","level":2,"score":0.5041433572769165},{"id":"https://openalex.org/C2780886216","wikidata":"https://www.wikidata.org/wiki/Q465444","display_name":"Prestressed concrete","level":2,"score":0.46303945779800415},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.41584789752960205},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.41076183319091797},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.37712010741233826},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3397839665412903},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.30061647295951843},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17760086059570312},{"id":"https://openalex.org/C105702510","wikidata":"https://www.wikidata.org/wiki/Q514","display_name":"Anatomy","level":1,"score":0.15517258644104004},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.12406614422798157},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.07261848449707031},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2023.3290988","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2023.3290988","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G2194342028","display_name":null,"funder_award_id":"51875477","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G6359950996","display_name":null,"funder_award_id":"52275545","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G7404377243","display_name":null,"funder_award_id":"2023-ZDLGY-41","funder_id":"https://openalex.org/F4320329783","funder_display_name":"Key Industry Innovation Chain of Shaanxi"},{"id":"https://openalex.org/G745719754","display_name":null,"funder_award_id":"EP/P001661/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320329783","display_name":"Key Industry Innovation Chain of Shaanxi","ror":null},{"id":"https://openalex.org/F4320334627","display_name":"Engineering and Physical Sciences Research Council","ror":"https://ror.org/0439y7842"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":30,"referenced_works":["https://openalex.org/W610553411","https://openalex.org/W1973394915","https://openalex.org/W2036261140","https://openalex.org/W2036323223","https://openalex.org/W2051053296","https://openalex.org/W2073046487","https://openalex.org/W2075731438","https://openalex.org/W2078819065","https://openalex.org/W2089787839","https://openalex.org/W2136807842","https://openalex.org/W2144645188","https://openalex.org/W2149324338","https://openalex.org/W2248392037","https://openalex.org/W2487644592","https://openalex.org/W2490447124","https://openalex.org/W2509443795","https://openalex.org/W2510104922","https://openalex.org/W2511618837","https://openalex.org/W2617183596","https://openalex.org/W2762826825","https://openalex.org/W2800355071","https://openalex.org/W2898932890","https://openalex.org/W2948731506","https://openalex.org/W3031682485","https://openalex.org/W3133776225","https://openalex.org/W3165899867","https://openalex.org/W4283757437","https://openalex.org/W4297818265","https://openalex.org/W6691058374","https://openalex.org/W6791542838"],"related_works":["https://openalex.org/W2389324249","https://openalex.org/W2386300132","https://openalex.org/W2523659113","https://openalex.org/W2351223753","https://openalex.org/W2391313674","https://openalex.org/W2355963886","https://openalex.org/W2393038550","https://openalex.org/W604555887","https://openalex.org/W2355883357","https://openalex.org/W2375489063"],"abstract_inverted_index":{"The":[0,18,71,85,143,158,191,204],"grouted":[1,27,38,108,112,225],"duct":[2,39,113],"is":[3,21,40,56,77,165],"an":[4,115],"important":[5],"part":[6,24],"of":[7,25,32,61,73,81,118,127,139,151,161,173,179,185,187,219],"the":[8,22,26,30,33,37,51,59,62,68,74,82,99,129,134,140,147,152,162,171,174,176,180,183,188,194,202,214,220,224],"bridge,":[9],"and":[10,13,29,65,94,103,120,136,182,196,216],"its":[11],"quality":[12,44],"safety":[14],"are":[15],"closely":[16],"related.":[17],"prestressed":[19,34,63,122,141,163,189,221],"tendon":[20,35,64,123,154,164,222],"crucial":[23],"duct,":[28],"positioning":[31,60,160],"in":[36,223],"a":[41,111,121,125],"prerequisite":[42],"for":[43,58,212],"evaluation.":[45],"Based":[46],"on":[47],"capacitive":[48,54,207],"sensing":[49],"technology,":[50],"three-electrode":[52,75,130,205],"Co-surface":[53],"sensor":[55,86,131,144,208],"designed":[57],"compared":[66],"with":[67,114,124,155],"dual-electrode":[69,83],"structure.":[70,84],"sensitivity":[72],"structure":[76,172],"about":[78],"twice":[79],"that":[80],"performance":[87],"was":[88],"evaluated":[89],"by":[90,167],"finite":[91],"element":[92],"simulations":[93],"experiments.":[95],"This":[96],"study":[97],"analyzed":[98],"differences":[100],"between":[101,193],"simulation":[102,197],"experimental":[104,195],"results":[105,198],"through":[106],"6":[107],"ducts.":[109],"For":[110],"inner":[116],"diameter":[117],"80mm":[119],"radius":[126],"8mm,":[128],"can":[132,145,209],"localize":[133],"angular":[135,215],"radial":[137,148,217],"position":[138,149,218],"tendon.":[142,190],"distinguish":[146],"change":[150],"prestressing":[153],"10mm":[156],"intervals.":[157],"precise":[159],"affected":[166],"factors":[168],"such":[169],"as":[170],"sensor,":[175],"material":[177],"properties":[178],"concrete,":[181],"degree":[184],"corrosion":[186],"difference":[192],"does":[199],"not":[200],"affect":[201],"conclusion.":[203],"co-surface":[206],"be":[210],"used":[211],"detecting":[213],"duct.":[226]},"counts_by_year":[{"year":2025,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
