{"id":"https://openalex.org/W4368232732","doi":"https://doi.org/10.1109/tim.2023.3268656","title":"Fast Emissivity Measuring Apparatus With Adjustable Focusing and Field Calibration","display_name":"Fast Emissivity Measuring Apparatus With Adjustable Focusing and Field Calibration","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4368232732","doi":"https://doi.org/10.1109/tim.2023.3268656"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2023.3268656","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/tim.2023.3268656","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010727438","display_name":"Baolin Zhao","orcid":"https://orcid.org/0000-0002-8203-3097"},"institutions":[{"id":"https://openalex.org/I75955062","display_name":"Henan Normal University","ror":"https://ror.org/00s13br28","country_code":"CN","type":"education","lineage":["https://openalex.org/I75955062"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Baolin Zhao","raw_affiliation_strings":["Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China"],"raw_orcid":"https://orcid.org/0000-0002-8203-3097","affiliations":[{"raw_affiliation_string":"Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","institution_ids":["https://openalex.org/I75955062"]},{"raw_affiliation_string":"School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China","institution_ids":["https://openalex.org/I75955062"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5031639211","display_name":"Kaihua Zhang","orcid":"https://orcid.org/0000-0002-1689-4550"},"institutions":[{"id":"https://openalex.org/I75955062","display_name":"Henan Normal University","ror":"https://ror.org/00s13br28","country_code":"CN","type":"education","lineage":["https://openalex.org/I75955062"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kaihua Zhang","raw_affiliation_strings":["Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China"],"raw_orcid":"https://orcid.org/0000-0002-1689-4550","affiliations":[{"raw_affiliation_string":"Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","institution_ids":["https://openalex.org/I75955062"]},{"raw_affiliation_string":"School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China","institution_ids":["https://openalex.org/I75955062"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018322940","display_name":"Kun Yu","orcid":"https://orcid.org/0000-0001-6578-1336"},"institutions":[{"id":"https://openalex.org/I75955062","display_name":"Henan Normal University","ror":"https://ror.org/00s13br28","country_code":"CN","type":"education","lineage":["https://openalex.org/I75955062"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kun Yu","raw_affiliation_strings":["Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China"],"raw_orcid":"https://orcid.org/0000-0001-6578-1336","affiliations":[{"raw_affiliation_string":"Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","institution_ids":["https://openalex.org/I75955062"]},{"raw_affiliation_string":"School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China","institution_ids":["https://openalex.org/I75955062"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100761343","display_name":"Yufang Liu","orcid":"https://orcid.org/0000-0003-1896-8864"},"institutions":[{"id":"https://openalex.org/I75955062","display_name":"Henan Normal University","ror":"https://ror.org/00s13br28","country_code":"CN","type":"education","lineage":["https://openalex.org/I75955062"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yufang Liu","raw_affiliation_strings":["Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China"],"raw_orcid":"https://orcid.org/0000-0003-1896-8864","affiliations":[{"raw_affiliation_string":"Henan Key Laboratory of Infrared Materials and Spectrum Measures and Applications, School of Physics, Henan Normal University, Xinxiang, Henan, China","institution_ids":["https://openalex.org/I75955062"]},{"raw_affiliation_string":"School of Physics, Henan key laboratory of infrared materials & spectrum measures and applications, Henan Normal University, Xinxiang, Henan, PR China","institution_ids":["https://openalex.org/I75955062"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I75955062"],"apc_list":null,"apc_paid":null,"fwci":5.0974,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.94794343,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":97},"biblio":{"volume":"72","issue":null,"first_page":"1","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11856","display_name":"Thermography and Photoacoustic Techniques","score":0.9959999918937683,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/emissivity","display_name":"Emissivity","score":0.9252471923828125},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6992038488388062},{"id":"https://openalex.org/keywords/optics","display_name":"Optics","score":0.6731581091880798},{"id":"https://openalex.org/keywords/silicon-carbide","display_name":"Silicon carbide","score":0.611897349357605},{"id":"https://openalex.org/keywords/spectrometer","display_name":"Spectrometer","score":0.5679375529289246},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.5287798643112183},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.45678481459617615},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.4301391839981079},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2785112261772156},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.1883309781551361}],"concepts":[{"id":"https://openalex.org/C163651212","wikidata":"https://www.wikidata.org/wiki/Q899670","display_name":"Emissivity","level":2,"score":0.9252471923828125},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6992038488388062},{"id":"https://openalex.org/C120665830","wikidata":"https://www.wikidata.org/wiki/Q14620","display_name":"Optics","level":1,"score":0.6731581091880798},{"id":"https://openalex.org/C2780722187","wikidata":"https://www.wikidata.org/wiki/Q412356","display_name":"Silicon carbide","level":2,"score":0.611897349357605},{"id":"https://openalex.org/C33390570","wikidata":"https://www.wikidata.org/wiki/Q188463","display_name":"Spectrometer","level":2,"score":0.5679375529289246},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.5287798643112183},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.45678481459617615},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.4301391839981079},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2785112261772156},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.1883309781551361},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C191897082","wikidata":"https://www.wikidata.org/wiki/Q11467","display_name":"Metallurgy","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2023.3268656","is_oa":false,"landing_page_url":"http://dx.doi.org/10.1109/tim.2023.3268656","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":0.5699999928474426,"id":"https://metadata.un.org/sdg/9"}],"awards":[{"id":"https://openalex.org/G1053993209","display_name":null,"funder_award_id":"222300420209","funder_id":"https://openalex.org/F4320323845","funder_display_name":"Natural Science Foundation of Henan Province"},{"id":"https://openalex.org/G342762760","display_name":null,"funder_award_id":"20200171","funder_id":"https://openalex.org/F4320311345","funder_display_name":"Henan Normal University"},{"id":"https://openalex.org/G3760515813","display_name":null,"funder_award_id":"22A140021","funder_id":"https://openalex.org/F4320335955","funder_display_name":"Key Scientific Research Project of Colleges and Universities in Henan Province"},{"id":"https://openalex.org/G6008116006","display_name":null,"funder_award_id":"23IRTSTHN013","funder_id":"https://openalex.org/F4320322878","funder_display_name":"Henan University"},{"id":"https://openalex.org/G6202098954","display_name":null,"funder_award_id":"62075058","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G7182312092","display_name":null,"funder_award_id":"222300420011","funder_id":"https://openalex.org/F4320323845","funder_display_name":"Natural Science Foundation of Henan Province"},{"id":"https://openalex.org/G8050431771","display_name":null,"funder_award_id":"224000510007","funder_id":"https://openalex.org/F4320327776","funder_display_name":"Innovation Scientists and Technicians Troop Construction Projects of Henan Province"},{"id":"https://openalex.org/G8059642333","display_name":null,"funder_award_id":"U1804261","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320311345","display_name":"Henan Normal University","ror":"https://ror.org/00s13br28"},{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320322878","display_name":"Henan University","ror":"https://ror.org/003xyzq10"},{"id":"https://openalex.org/F4320323845","display_name":"Natural Science Foundation of Henan Province","ror":null},{"id":"https://openalex.org/F4320327776","display_name":"Innovation Scientists and Technicians Troop Construction Projects of Henan Province","ror":null},{"id":"https://openalex.org/F4320335955","display_name":"Key Scientific Research Project of Colleges and Universities in Henan Province","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":49,"referenced_works":["https://openalex.org/W1198369850","https://openalex.org/W1814973469","https://openalex.org/W1913815982","https://openalex.org/W1975099518","https://openalex.org/W1981396443","https://openalex.org/W1981636125","https://openalex.org/W1983431539","https://openalex.org/W2013125540","https://openalex.org/W2017046529","https://openalex.org/W2019795571","https://openalex.org/W2029652333","https://openalex.org/W2036521608","https://openalex.org/W2049123304","https://openalex.org/W2089219595","https://openalex.org/W2094228744","https://openalex.org/W2114313713","https://openalex.org/W2118003784","https://openalex.org/W2123873447","https://openalex.org/W2168292799","https://openalex.org/W2202589295","https://openalex.org/W2311154158","https://openalex.org/W2428542943","https://openalex.org/W2466128349","https://openalex.org/W2466686045","https://openalex.org/W2544315124","https://openalex.org/W2546956049","https://openalex.org/W2586079435","https://openalex.org/W2624310273","https://openalex.org/W2731387524","https://openalex.org/W2744669521","https://openalex.org/W2750705428","https://openalex.org/W2808553924","https://openalex.org/W2811298999","https://openalex.org/W2903499875","https://openalex.org/W2917996504","https://openalex.org/W2946822046","https://openalex.org/W2991259777","https://openalex.org/W2993010764","https://openalex.org/W2993521278","https://openalex.org/W3013860733","https://openalex.org/W3112865609","https://openalex.org/W3134590420","https://openalex.org/W3135118009","https://openalex.org/W3178680665","https://openalex.org/W3198548158","https://openalex.org/W4205645209","https://openalex.org/W4244657392","https://openalex.org/W6628220564","https://openalex.org/W6684370726"],"related_works":["https://openalex.org/W2092610690","https://openalex.org/W2360511589","https://openalex.org/W1567094779","https://openalex.org/W2571987858","https://openalex.org/W2993521278","https://openalex.org/W292381545","https://openalex.org/W70117827","https://openalex.org/W1635724746","https://openalex.org/W2114776132","https://openalex.org/W2027886253"],"abstract_inverted_index":{"A":[0],"fast":[1],"emissivity":[2,46,125,144,211],"measuring":[3],"apparatus":[4,70,102,147,173],"in":[5,26,44,48,95,122,149,187],"the":[6,31,38,42,75,78,83,86,90,101,104,107,112,120,136,140,146,153,160,163,180,188,204,209],"range":[7,190],"of":[8,37,68,77,100,126,142,155,162,168,171,191,208,212],"1.4\u2013<inline-formula":[9,192],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[10,193],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">":[11,194],"<tex-math":[12,195],"notation=\"LaTeX\">$2.5":[13,196],"\\mu":[14,197],"\\text{m}$":[15,198],"</tex-math></inline-formula>":[16],"with":[17,119,152],"adjustable":[18],"focusing":[19],"and":[20,34,82,89,130,139,179],"field":[21],"calibration":[22],"has":[23],"been":[24],"developed":[25],"this":[27,62,69,172],"article.":[28],"Benefiting":[29],"from":[30],"portable,":[32],"fast,":[33],"efficient":[35],"characteristics":[36],"fiber":[39],"optic":[40],"spectrometer,":[41],"rapid":[43],"situ":[45],"measurement":[47,113],"industry,":[49],"such":[50],"as":[51],"aluminum":[52],"profile":[53],"casting":[54],"or":[55],"molten-salt":[56],"monitoring,":[57],"can":[58],"be":[59],"realized":[60],"by":[61,135,145],"apparatus.":[63,164],"The":[64,97,124,165],"light":[65],"path":[66],"system":[67],"is":[71,93,133,174,183,214],"designed":[72],"based":[73],"on":[74],"principle":[76],"Newtonian":[79],"reflecting":[80],"telescope,":[81],"relationship":[84],"between":[85],"radiation":[87,105,170],"signal":[88,114],"object":[91],"distance":[92],"analyzed":[94],"detail.":[96],"focus":[98],"adjustment":[99],"improves":[103],"entering":[106],"system,":[108],"thus":[109],"ensuring":[110],"that":[111],"does":[115],"not":[116,175],"decrease":[117],"rapidly":[118],"increase":[121],"distance.":[123],"silicon":[127,132],"carbide":[128],"(SIC)":[129],"pure":[131],"calculated":[134],"Fresnel":[137],"formula":[138],"results":[141],"measured":[143],"are":[148],"good":[150],"agreement":[151],"data":[154],"theoretical":[156],"calculation,":[157],"which":[158],"verifies":[159],"reliability":[161],"maximum":[166],"error":[167,182],"calibrated":[169],"more":[176],"than":[177,185,216],"2.5%,":[178],"average":[181],"less":[184,215],"1%":[186],"wavelength":[189],"</tex-math></inline-formula>.":[199],"In":[200],"a":[201],"feasibility":[202],"test,":[203],"relative":[205],"combined":[206],"uncertainty":[207],"spectral":[210],"SIC":[213],"5.73%.":[217]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2}],"updated_date":"2025-12-21T01:58:51.020947","created_date":"2025-10-10T00:00:00"}
