{"id":"https://openalex.org/W4323767284","doi":"https://doi.org/10.1109/tim.2023.3251392","title":"Clinical Validation of a Capacitive Electrocardiogram Cushion Utilized for Arrhythmias Monitoring","display_name":"Clinical Validation of a Capacitive Electrocardiogram Cushion Utilized for Arrhythmias Monitoring","publication_year":2023,"publication_date":"2023-01-01","ids":{"openalex":"https://openalex.org/W4323767284","doi":"https://doi.org/10.1109/tim.2023.3251392"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2023.3251392","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2023.3251392","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5064823120","display_name":"Yonglin Wu","orcid":"https://orcid.org/0000-0001-6177-0517"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Yonglin Wu","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012873180","display_name":"Ke Xu","orcid":"https://orcid.org/0000-0001-7376-2805"},"institutions":[{"id":"https://openalex.org/I47508984","display_name":"Imperial College London","ror":"https://ror.org/041kmwe10","country_code":"GB","type":"education","lineage":["https://openalex.org/I47508984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Ke Xu","raw_affiliation_strings":["Department of Infectious Disease, Faculty of Medicine, Imperial College London, London, U.K","Onesense Medical Technology (Suzhou) Co., Ltd, China"],"affiliations":[{"raw_affiliation_string":"Department of Infectious Disease, Faculty of Medicine, Imperial College London, London, U.K","institution_ids":["https://openalex.org/I47508984"]},{"raw_affiliation_string":"Onesense Medical Technology (Suzhou) Co., Ltd, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103169708","display_name":"Shun Peng","orcid":"https://orcid.org/0000-0001-7573-9940"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shun Peng","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5070707520","display_name":"Yizhou Cao","orcid":"https://orcid.org/0000-0003-4170-5712"},"institutions":[{"id":"https://openalex.org/I2801556517","display_name":"Ruijin Hospital","ror":"https://ror.org/01hv94n30","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I2801556517"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yizhou Cao","raw_affiliation_strings":["Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China","Ruijin Hospital, Shanghai Jiaotong University School Of Medicine, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China","institution_ids":["https://openalex.org/I2801556517"]},{"raw_affiliation_string":"Ruijin Hospital, Shanghai Jiaotong University School Of Medicine, Shanghai, China","institution_ids":["https://openalex.org/I2801556517"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033165708","display_name":"Yongwen Huang","orcid":"https://orcid.org/0000-0001-7082-5903"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yongwen Huang","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5026564031","display_name":"Rui Cui","orcid":"https://orcid.org/0000-0002-5106-195X"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Rui Cui","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012692165","display_name":"Hangyu Zhu","orcid":"https://orcid.org/0000-0003-3211-5358"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hangyu Zhu","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101544334","display_name":"Yao Guo","orcid":"https://orcid.org/0000-0002-9300-5817"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yao Guo","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051572554","display_name":"Zhen Wang","orcid":"https://orcid.org/0000-0003-1426-8094"},"institutions":[{"id":"https://openalex.org/I157773358","display_name":"Sun Yat-sen University","ror":"https://ror.org/0064kty71","country_code":"CN","type":"education","lineage":["https://openalex.org/I157773358"]},{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]},{"id":"https://openalex.org/I4210089514","display_name":"National Clinical Research Center for Digestive Diseases","ror":"https://ror.org/00a2x9d51","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210089514"]},{"id":"https://openalex.org/I4210127074","display_name":"Zhongshan Hospital","ror":"https://ror.org/032x22645","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210127074"]},{"id":"https://openalex.org/I4210128921","display_name":"The First Affiliated Hospital, Sun Yat-sen University","ror":"https://ror.org/037p24858","country_code":"CN","type":"healthcare","lineage":["https://openalex.org/I4210128921"]},{"id":"https://openalex.org/I4210147369","display_name":"Shanghai Institute of Hematology","ror":"https://ror.org/03fz4ce66","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210147369"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhen Wang","raw_affiliation_strings":["Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China","National Clinical Research Center for Interventional Medicine, China","Shanghai Institute of Cardiovascular Diseases, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I4210128921","https://openalex.org/I4210127074","https://openalex.org/I24943067","https://openalex.org/I157773358"]},{"raw_affiliation_string":"National Clinical Research Center for Interventional Medicine, China","institution_ids":["https://openalex.org/I4210089514"]},{"raw_affiliation_string":"Shanghai Institute of Cardiovascular Diseases, Shanghai, China","institution_ids":["https://openalex.org/I4210147369"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5076568602","display_name":"Chenyun Dai","orcid":"https://orcid.org/0000-0002-3056-4339"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chenyun Dai","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5100344582","display_name":"Wei Chen","orcid":"https://orcid.org/0000-0003-3720-718X"},"institutions":[{"id":"https://openalex.org/I24943067","display_name":"Fudan University","ror":"https://ror.org/013q1eq08","country_code":"CN","type":"education","lineage":["https://openalex.org/I24943067"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wei Chen","raw_affiliation_strings":["Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China"],"affiliations":[{"raw_affiliation_string":"Center for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]},{"raw_affiliation_string":"School of Information Science and Technology, Center for Intelligent Medical Electronics, Fudan University, Shanghai, China","institution_ids":["https://openalex.org/I24943067"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":11,"corresponding_author_ids":["https://openalex.org/A5064823120"],"corresponding_institution_ids":["https://openalex.org/I24943067"],"apc_list":null,"apc_paid":null,"fwci":1.3177,"has_fulltext":false,"cited_by_count":6,"citation_normalized_percentile":{"value":0.81606913,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":96,"max":97},"biblio":{"volume":"72","issue":null,"first_page":"1","last_page":"13"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10784","display_name":"Muscle activation and electromyography studies","score":0.9940000176429749,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/supraventricular-arrhythmia","display_name":"Supraventricular arrhythmia","score":0.5852608680725098},{"id":"https://openalex.org/keywords/electrocardiography","display_name":"Electrocardiography","score":0.5705912113189697},{"id":"https://openalex.org/keywords/cushion","display_name":"Cushion","score":0.5369998812675476},{"id":"https://openalex.org/keywords/alarm","display_name":"ALARM","score":0.5330079197883606},{"id":"https://openalex.org/keywords/cardiology","display_name":"Cardiology","score":0.48916271328926086},{"id":"https://openalex.org/keywords/cardiac-arrhythmia","display_name":"Cardiac arrhythmia","score":0.4606935679912567},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.41922321915626526},{"id":"https://openalex.org/keywords/internal-medicine","display_name":"Internal medicine","score":0.4185390770435333},{"id":"https://openalex.org/keywords/heart-rate-variability","display_name":"Heart rate variability","score":0.4110924005508423},{"id":"https://openalex.org/keywords/biomedical-engineering","display_name":"Biomedical engineering","score":0.40477901697158813},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.33264124393463135},{"id":"https://openalex.org/keywords/heart-rate","display_name":"Heart rate","score":0.28559041023254395},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2713117003440857},{"id":"https://openalex.org/keywords/atrial-fibrillation","display_name":"Atrial fibrillation","score":0.21774238348007202},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.17662179470062256},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.14773809909820557}],"concepts":[{"id":"https://openalex.org/C2910597771","wikidata":"https://www.wikidata.org/wiki/Q1598909","display_name":"Supraventricular arrhythmia","level":3,"score":0.5852608680725098},{"id":"https://openalex.org/C2780040984","wikidata":"https://www.wikidata.org/wiki/Q79785","display_name":"Electrocardiography","level":2,"score":0.5705912113189697},{"id":"https://openalex.org/C2780584845","wikidata":"https://www.wikidata.org/wiki/Q10971235","display_name":"Cushion","level":2,"score":0.5369998812675476},{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.5330079197883606},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.48916271328926086},{"id":"https://openalex.org/C2988455589","wikidata":"https://www.wikidata.org/wiki/Q189331","display_name":"Cardiac arrhythmia","level":3,"score":0.4606935679912567},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.41922321915626526},{"id":"https://openalex.org/C126322002","wikidata":"https://www.wikidata.org/wiki/Q11180","display_name":"Internal medicine","level":1,"score":0.4185390770435333},{"id":"https://openalex.org/C71635504","wikidata":"https://www.wikidata.org/wiki/Q933954","display_name":"Heart rate variability","level":4,"score":0.4110924005508423},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.40477901697158813},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33264124393463135},{"id":"https://openalex.org/C2777953023","wikidata":"https://www.wikidata.org/wiki/Q1073121","display_name":"Heart rate","level":3,"score":0.28559041023254395},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2713117003440857},{"id":"https://openalex.org/C2779161974","wikidata":"https://www.wikidata.org/wiki/Q815819","display_name":"Atrial fibrillation","level":2,"score":0.21774238348007202},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.17662179470062256},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.14773809909820557},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2023.3251392","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2023.3251392","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G6627153076","display_name":null,"funder_award_id":"19MC1910300","funder_id":"https://openalex.org/F4320329601","funder_display_name":"Shanghai Clinical Research Center"}],"funders":[{"id":"https://openalex.org/F4320329601","display_name":"Shanghai Clinical Research Center","ror":"https://ror.org/057tkkm33"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":45,"referenced_works":["https://openalex.org/W1928755576","https://openalex.org/W1975938786","https://openalex.org/W1977787838","https://openalex.org/W1978431198","https://openalex.org/W1991860678","https://openalex.org/W2028912369","https://openalex.org/W2031417525","https://openalex.org/W2038436648","https://openalex.org/W2041691167","https://openalex.org/W2043965817","https://openalex.org/W2055741845","https://openalex.org/W2072865100","https://openalex.org/W2076151226","https://openalex.org/W2118202495","https://openalex.org/W2136177393","https://openalex.org/W2145988291","https://openalex.org/W2152846380","https://openalex.org/W2395572751","https://openalex.org/W2575291428","https://openalex.org/W2621727638","https://openalex.org/W2765422460","https://openalex.org/W2778978785","https://openalex.org/W2806290004","https://openalex.org/W2806660488","https://openalex.org/W2827727045","https://openalex.org/W2886367177","https://openalex.org/W2886982273","https://openalex.org/W2911278415","https://openalex.org/W2936354642","https://openalex.org/W2967958120","https://openalex.org/W2979578963","https://openalex.org/W2982002184","https://openalex.org/W3005762221","https://openalex.org/W3010700465","https://openalex.org/W3015802815","https://openalex.org/W3033603788","https://openalex.org/W3037065443","https://openalex.org/W3053117764","https://openalex.org/W3112178328","https://openalex.org/W3112204318","https://openalex.org/W3157109561","https://openalex.org/W3171411730","https://openalex.org/W3175128625","https://openalex.org/W4210242902","https://openalex.org/W4226203950"],"related_works":["https://openalex.org/W2357619269","https://openalex.org/W2358678369","https://openalex.org/W3097894411","https://openalex.org/W2075608093","https://openalex.org/W2171736211","https://openalex.org/W3031545524","https://openalex.org/W2368539024","https://openalex.org/W2683519576","https://openalex.org/W2095462766","https://openalex.org/W2502772723"],"abstract_inverted_index":{"Textile":[0],"capacitively-coupled":[1],"(CC)":[2],"electrodes":[3],"have":[4],"the":[5,34,43,115,124,130,144],"potential":[6],"of":[7,37,46,53,96,103,110,157,169,174],"being":[8],"integrated":[9],"into":[10],"home":[11],"textiles":[12],"to":[13,93,128,149],"realize":[14],"long-term":[15,140,175],"cardiac":[16,176],"surveillance,":[17],"since":[18],"they":[19],"are":[20],"more":[21],"comfortable":[22],"and":[23,72,76,87,135,166],"convenient":[24],"than":[25],"conventional":[26],"contact":[27],"electrodes.":[28],"Previous":[29],"study":[30],"mainly":[31],"focused":[32],"on":[33,83],"measurement":[35,74,95],"performance":[36,75],"CC-based":[38,69],"electrocardiogram":[39],"(ECG)":[40],"devices,":[41,49],"but":[42],"diagnostic":[44,77],"value":[45,78],"these":[47],"novel":[48],"such":[50],"as":[51,159],"capability":[52],"supporting":[54],"preliminary":[55,155],"arrhythmia":[56,89,170],"diagnosis,":[57],"has":[58],"not":[59],"been":[60],"investigated":[61],"comprehensively.":[62],"In":[63,91,142],"this":[64],"study,":[65],"we":[66],"proposed":[67,116,145],"a":[68,80,160],"ECG":[70,98],"cushion":[71,117,146],"assessed":[73],"by":[79],"clinical":[81],"test":[82],"4":[84],"healthy":[85],"people":[86],"7":[88],"patients.":[90],"addition":[92],"precise":[94],"critical":[97],"structures":[99],"(true":[100],"positive":[101],"rate":[102],"R":[104],"waves:":[105],"0.994\u00b10.006,":[106],"mean":[107],"absolute":[108],"error":[109],"RR":[111],"intervals:":[112],"1.690\u00b11.331":[113],"ms),":[114],"can":[118],"provide":[119,150],"valuable":[120],"information,":[121],"comparable":[122],"with":[123],"Holter,":[125],"for":[126,154,163],"cardiologists":[127],"distinguish":[129],"normal":[131],"beats,":[132],"ventricular":[133],"beats":[134],"premature":[136],"supraventricular":[137],"contractions":[138],"during":[139],"monitoring.":[141],"conclusion,":[143],"is":[147],"verified":[148],"enough":[151],"signal":[152],"details":[153],"diagnosis":[156],"arrhythmia,":[158],"promising":[161],"system":[162],"disease":[164],"screen":[165],"danger":[167],"alarm":[168],"in":[171],"certain":[172],"scenario":[173],"surveillance":[177],"at":[178],"home.":[179]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":3}],"updated_date":"2026-03-27T05:58:40.876381","created_date":"2025-10-10T00:00:00"}
