{"id":"https://openalex.org/W4285273923","doi":"https://doi.org/10.1109/tim.2022.3178738","title":"Suppression of Nonuniform Magnetic Fields in Magnetic Shielding System for SERF Co-Magnetometer","display_name":"Suppression of Nonuniform Magnetic Fields in Magnetic Shielding System for SERF Co-Magnetometer","publication_year":2022,"publication_date":"2022-01-01","ids":{"openalex":"https://openalex.org/W4285273923","doi":"https://doi.org/10.1109/tim.2022.3178738"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2022.3178738","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2022.3178738","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5021148241","display_name":"Yang Fu","orcid":"https://orcid.org/0000-0002-9817-0619"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yang Fu","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China"],"raw_orcid":"https://orcid.org/0000-0002-9817-0619","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]},{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029221427","display_name":"Zhuo Wang","orcid":"https://orcid.org/0000-0002-2735-6969"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhuo Wang","raw_affiliation_strings":["Beihang Hangzhou Innovation Institute Yuhang, Hangzhou, China","Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China, and Research Institute for Frontier Science, and The Key Laboratory of Ministry of Industry and Information Technology on Quantum Sensing Technology, Beihang University, Beijing 100191, China"],"raw_orcid":"https://orcid.org/0000-0002-2735-6969","affiliations":[{"raw_affiliation_string":"Beihang Hangzhou Innovation Institute Yuhang, Hangzhou, China","institution_ids":[]},{"raw_affiliation_string":"Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China, and Research Institute for Frontier Science, and The Key Laboratory of Ministry of Industry and Information Technology on Quantum Sensing Technology, Beihang University, Beijing 100191, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5029926016","display_name":"Xing Li","orcid":"https://orcid.org/0000-0003-3300-8132"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Li Xing","raw_affiliation_strings":["Division of Thermophysics and Process Measurements, National Institute of Metrology (NIM), Beijing, China","Division of Thermophysics and Process Measurements, National Institute of Metrology, NIM, Beijing 100029, China"],"raw_orcid":"https://orcid.org/0000-0003-3300-8132","affiliations":[{"raw_affiliation_string":"Division of Thermophysics and Process Measurements, National Institute of Metrology (NIM), Beijing, China","institution_ids":["https://openalex.org/I4210162136"]},{"raw_affiliation_string":"Division of Thermophysics and Process Measurements, National Institute of Metrology, NIM, Beijing 100029, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5050566348","display_name":"Wenfeng Fan","orcid":"https://orcid.org/0000-0002-8624-9215"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wenfeng Fan","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China"],"raw_orcid":"https://orcid.org/0000-0002-8624-9215","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]},{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5066191068","display_name":"Jiasen Ruan","orcid":"https://orcid.org/0000-0003-4408-0279"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiasen Ruan","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China"],"raw_orcid":"https://orcid.org/0000-0003-4408-0279","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]},{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048616943","display_name":"Haoying Pang","orcid":"https://orcid.org/0000-0002-6219-1231"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haoying Pang","raw_affiliation_strings":["School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China"],"raw_orcid":"https://orcid.org/0000-0002-6219-1231","affiliations":[{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]},{"raw_affiliation_string":"School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China, and Beihang Hangzhou Innovation Institute Yuhang, Xixi Octagon City, Yuhang District, Hangzhou 310023, China","institution_ids":["https://openalex.org/I82880672"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":2.9732,"has_fulltext":false,"cited_by_count":25,"citation_normalized_percentile":{"value":0.92097589,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"71","issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9973000288009644,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11809","display_name":"Advanced NMR Techniques and Applications","score":0.9937999844551086,"subfield":{"id":"https://openalex.org/subfields/1607","display_name":"Spectroscopy"},"field":{"id":"https://openalex.org/fields/16","display_name":"Chemistry"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/magnetometer","display_name":"Magnetometer","score":0.8377984762191772},{"id":"https://openalex.org/keywords/electromagnetic-shielding","display_name":"Electromagnetic shielding","score":0.7933404445648193},{"id":"https://openalex.org/keywords/magnetic-noise","display_name":"Magnetic noise","score":0.5765386819839478},{"id":"https://openalex.org/keywords/magnetic-field","display_name":"Magnetic field","score":0.5470184087753296},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.5026068687438965},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.4607546925544739},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.33672648668289185},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3283214271068573},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2172483205795288}],"concepts":[{"id":"https://openalex.org/C153946474","wikidata":"https://www.wikidata.org/wiki/Q333921","display_name":"Magnetometer","level":3,"score":0.8377984762191772},{"id":"https://openalex.org/C2265751","wikidata":"https://www.wikidata.org/wiki/Q332007","display_name":"Electromagnetic shielding","level":2,"score":0.7933404445648193},{"id":"https://openalex.org/C2983215976","wikidata":"https://www.wikidata.org/wiki/Q5141464","display_name":"Magnetic noise","level":3,"score":0.5765386819839478},{"id":"https://openalex.org/C115260700","wikidata":"https://www.wikidata.org/wiki/Q11408","display_name":"Magnetic field","level":2,"score":0.5470184087753296},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.5026068687438965},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.4607546925544739},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.33672648668289185},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3283214271068573},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2172483205795288},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2022.3178738","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2022.3178738","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[{"id":"https://openalex.org/G246606981","display_name":null,"funder_award_id":"2021B0101410005","funder_id":"https://openalex.org/F4320336405","funder_display_name":"Special Project for Research and Development in Key areas of Guangdong Province"},{"id":"https://openalex.org/G8365184137","display_name":null,"funder_award_id":"61,673,041","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"},{"id":"https://openalex.org/G848868329","display_name":null,"funder_award_id":"2021M703049","funder_id":"https://openalex.org/F4320321543","funder_display_name":"China Postdoctoral Science Foundation"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"},{"id":"https://openalex.org/F4320321543","display_name":"China Postdoctoral Science Foundation","ror":"https://ror.org/0426zh255"},{"id":"https://openalex.org/F4320336405","display_name":"Special Project for Research and Development in Key areas of Guangdong Province","ror":null}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":27,"referenced_works":["https://openalex.org/W1994996514","https://openalex.org/W1998320990","https://openalex.org/W2021509196","https://openalex.org/W2024722184","https://openalex.org/W2024814797","https://openalex.org/W2044227619","https://openalex.org/W2069474037","https://openalex.org/W2074378897","https://openalex.org/W2084327784","https://openalex.org/W2091146774","https://openalex.org/W2106167652","https://openalex.org/W2107998420","https://openalex.org/W2126115658","https://openalex.org/W2131775935","https://openalex.org/W2146477972","https://openalex.org/W2149060128","https://openalex.org/W2157409049","https://openalex.org/W2480200965","https://openalex.org/W2509759833","https://openalex.org/W2746720193","https://openalex.org/W2800277557","https://openalex.org/W2963387834","https://openalex.org/W2986893055","https://openalex.org/W3098191548","https://openalex.org/W3104430908","https://openalex.org/W3106043300","https://openalex.org/W4214951056"],"related_works":["https://openalex.org/W3046171984","https://openalex.org/W2137094089","https://openalex.org/W2885295284","https://openalex.org/W1619180110","https://openalex.org/W4388428235","https://openalex.org/W2522577304","https://openalex.org/W1644379107","https://openalex.org/W2125500725","https://openalex.org/W2086481172","https://openalex.org/W2064206114"],"abstract_inverted_index":{"Spin-exchange":[0],"relaxation-free":[1],"(SERF)":[2],"co-magnetometer":[3,35,57,169],"typically":[4],"use":[5],"a":[6,82,139],"low-noise":[7,20],"magnetic":[8,21,27,68,74,112,126,143],"shield":[9],"system,":[10],"which":[11,60,149],"is":[12,31,58,89,160,170],"composed":[13],"of":[14,50,66,73,130,166],"outer":[15],"&#x03BC;-metal":[16],"shields":[17,69,132],"and":[18,40,70,91,123],"inner":[19],"shield,":[22],"to":[23,36],"provide":[24],"the":[25,34,55,62,71,94,110,115,125,131,141,152,157,163,167],"required":[26],"environment.":[28],"Proper":[29],"degaussing":[30,51,63,84,98,106],"essential":[32],"for":[33,54],"obtain":[37],"low":[38],"remanence":[39],"field":[41,113],"gradient.":[42],"In":[43],"this":[44,105],"paper,":[45],"an":[46],"improved":[47],"design":[48],"method":[49],"device":[52,85,107],"suitable":[53],"SERF":[56,168],"proposed,":[59],"considers":[61],"performance":[64],"demand":[65],"multi-material":[67],"introduction":[72],"noise":[75,165],"by":[76,119,134,172],"metal":[77],"materials.":[78],"Based":[79],"on":[80],"this,":[81],"coil-shaped":[83],"in":[86,114],"separate":[87],"type":[88],"designed":[90],"compared":[92],"with":[93],"existing":[95],"detachable":[96],"pole-shaped":[97],"device.":[99],"The":[100],"experimental":[101],"results":[102],"show":[103],"that":[104,156],"can":[108,145],"reduce":[109,124],"residual":[111],"three":[116],"axis":[117],"directions":[118],"more":[120,135],"than":[121,136],"65%,":[122],"gradient":[127],"within":[128],"&#x00B1;10mm":[129],"center":[133],"80%.":[137],"As":[138],"result,":[140],"non-uniform":[142],"fields":[144],"be":[146],"effectively":[147],"reduced,":[148],"greatly":[150],"suppress":[151],"electron":[153],"relaxation":[154],"so":[155],"signal-to-noise":[158],"ratio":[159],"improved.":[161],"Furthermore,":[162],"signal":[164],"reduced":[171],"about":[173],"25%.":[174]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":11},{"year":2024,"cited_by_count":5},{"year":2023,"cited_by_count":6},{"year":2022,"cited_by_count":1}],"updated_date":"2026-08-01T09:00:35.917206","created_date":"2025-10-10T00:00:00"}
