{"id":"https://openalex.org/W3048438842","doi":"https://doi.org/10.1109/tim.2020.3015605","title":"A Comparison of Front-End Amplifiers for Tetrapolar Bioimpedance Measurements","display_name":"A Comparison of Front-End Amplifiers for Tetrapolar Bioimpedance Measurements","publication_year":2020,"publication_date":"2020-08-11","ids":{"openalex":"https://openalex.org/W3048438842","doi":"https://doi.org/10.1109/tim.2020.3015605","mag":"3048438842"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2020.3015605","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tim.2020.3015605","pdf_url":"https://ieeexplore.ieee.org/ielx7/19/9259274/09164909.pdf","source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://ieeexplore.ieee.org/ielx7/19/9259274/09164909.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5009743607","display_name":"Panagiotis Kassanos","orcid":"https://orcid.org/0000-0003-4597-8558"},"institutions":[{"id":"https://openalex.org/I47508984","display_name":"Imperial College London","ror":"https://ror.org/041kmwe10","country_code":"GB","type":"education","lineage":["https://openalex.org/I47508984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Panagiotis Kassanos","raw_affiliation_strings":["The Hamlyn Centre, Institute of Global Health Innovation, Imperial College London, London, U.K"],"raw_orcid":"https://orcid.org/0000-0003-4597-8558","affiliations":[{"raw_affiliation_string":"The Hamlyn Centre, Institute of Global Health Innovation, Imperial College London, London, U.K","institution_ids":["https://openalex.org/I47508984"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079576982","display_name":"Florent Seichepine","orcid":"https://orcid.org/0000-0001-5063-0367"},"institutions":[{"id":"https://openalex.org/I47508984","display_name":"Imperial College London","ror":"https://ror.org/041kmwe10","country_code":"GB","type":"education","lineage":["https://openalex.org/I47508984"]}],"countries":["GB"],"is_corresponding":false,"raw_author_name":"Florent Seichepine","raw_affiliation_strings":["The Hamlyn Centre, Institute of Global Health Innovation, Imperial College London, London, U.K"],"raw_orcid":"https://orcid.org/0000-0001-5063-0367","affiliations":[{"raw_affiliation_string":"The Hamlyn Centre, Institute of Global Health Innovation, Imperial College London, London, U.K","institution_ids":["https://openalex.org/I47508984"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5085036036","display_name":"Guang\u2010Zhong Yang","orcid":"https://orcid.org/0000-0003-4060-4020"},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]},{"id":"https://openalex.org/I47508984","display_name":"Imperial College London","ror":"https://ror.org/041kmwe10","country_code":"GB","type":"education","lineage":["https://openalex.org/I47508984"]}],"countries":["CN","GB"],"is_corresponding":false,"raw_author_name":"Guang-Zhong Yang","raw_affiliation_strings":["Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China","The Hamlyn Centre, Institute of Global Health Innovation, Imperial College London, London, U.K"],"raw_orcid":"https://orcid.org/0000-0003-4060-4020","affiliations":[{"raw_affiliation_string":"Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]},{"raw_affiliation_string":"The Hamlyn Centre, Institute of Global Health Innovation, Imperial College London, London, U.K","institution_ids":["https://openalex.org/I47508984"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.8325,"has_fulltext":true,"cited_by_count":14,"citation_normalized_percentile":{"value":0.72981294,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"70","issue":null,"first_page":"1","last_page":"14"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12279","display_name":"Body Composition Measurement Techniques","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2737","display_name":"Physiology"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9934999942779541,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.7563725113868713},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.6421163082122803},{"id":"https://openalex.org/keywords/resistor","display_name":"Resistor","score":0.5717313289642334},{"id":"https://openalex.org/keywords/front-and-back-ends","display_name":"Front and back ends","score":0.5034820437431335},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.45619186758995056},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.3958006203174591},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.351961612701416},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.2571723759174347},{"id":"https://openalex.org/keywords/mechanical-engineering","display_name":"Mechanical engineering","score":0.1459658145904541},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.0746472179889679}],"concepts":[{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.7563725113868713},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.6421163082122803},{"id":"https://openalex.org/C137488568","wikidata":"https://www.wikidata.org/wiki/Q5321","display_name":"Resistor","level":3,"score":0.5717313289642334},{"id":"https://openalex.org/C53016008","wikidata":"https://www.wikidata.org/wiki/Q620167","display_name":"Front and back ends","level":2,"score":0.5034820437431335},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.45619186758995056},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3958006203174591},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.351961612701416},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2571723759174347},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.1459658145904541},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.0746472179889679}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tim.2020.3015605","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tim.2020.3015605","pdf_url":"https://ieeexplore.ieee.org/ielx7/19/9259274/09164909.pdf","source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:spiral.imperial.ac.uk:10044/1/102797","is_oa":true,"landing_page_url":"http://hdl.handle.net/10044/1/102797","pdf_url":null,"source":{"id":"https://openalex.org/S4306401396","display_name":"Spiral (Imperial College London)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I47508984","host_organization_name":"Imperial College London","host_organization_lineage":["https://openalex.org/I47508984"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"14","raw_type":"Journal Article"}],"best_oa_location":{"id":"doi:10.1109/tim.2020.3015605","is_oa":true,"landing_page_url":"https://doi.org/10.1109/tim.2020.3015605","pdf_url":"https://ieeexplore.ieee.org/ielx7/19/9259274/09164909.pdf","source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.5699999928474426,"id":"https://metadata.un.org/sdg/7"}],"awards":[{"id":"https://openalex.org/G2819266950","display_name":null,"funder_award_id":"EP/P012779/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G367728017","display_name":"Smart Sensing for Surgery","funder_award_id":"EP/L014149/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G6468914036","display_name":null,"funder_award_id":"EP/P012779","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G6687449722","display_name":null,"funder_award_id":"EP/L014149/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"},{"id":"https://openalex.org/G793360779","display_name":"Micro-Robotics for Surgery","funder_award_id":"EP/P012779/1","funder_id":"https://openalex.org/F4320334627","funder_display_name":"Engineering and Physical Sciences Research Council"}],"funders":[{"id":"https://openalex.org/F4320334627","display_name":"Engineering and Physical Sciences Research Council","ror":"https://ror.org/0439y7842"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W3048438842.pdf","grobid_xml":"https://content.openalex.org/works/W3048438842.grobid-xml"},"referenced_works_count":49,"referenced_works":["https://openalex.org/W1519534852","https://openalex.org/W1551475221","https://openalex.org/W1952300823","https://openalex.org/W1966077412","https://openalex.org/W1970676909","https://openalex.org/W1979724394","https://openalex.org/W1979844585","https://openalex.org/W1995492397","https://openalex.org/W2004460525","https://openalex.org/W2006846449","https://openalex.org/W2012122748","https://openalex.org/W2017428114","https://openalex.org/W2025490457","https://openalex.org/W2029352896","https://openalex.org/W2039518448","https://openalex.org/W2041993119","https://openalex.org/W2047589674","https://openalex.org/W2048564825","https://openalex.org/W2051691547","https://openalex.org/W2055637338","https://openalex.org/W2071177160","https://openalex.org/W2074122741","https://openalex.org/W2074258298","https://openalex.org/W2074363709","https://openalex.org/W2081435823","https://openalex.org/W2090254314","https://openalex.org/W2093262630","https://openalex.org/W2094624944","https://openalex.org/W2101550277","https://openalex.org/W2104456441","https://openalex.org/W2110528670","https://openalex.org/W2112590669","https://openalex.org/W2113147953","https://openalex.org/W2119961192","https://openalex.org/W2127962890","https://openalex.org/W2148936942","https://openalex.org/W2149262807","https://openalex.org/W2161105431","https://openalex.org/W2161248222","https://openalex.org/W2167236033","https://openalex.org/W2312852763","https://openalex.org/W2315609349","https://openalex.org/W2561948967","https://openalex.org/W2766981235","https://openalex.org/W2786528761","https://openalex.org/W2794463799","https://openalex.org/W2898196415","https://openalex.org/W6698649798","https://openalex.org/W6699352918"],"related_works":["https://openalex.org/W3200817179","https://openalex.org/W1960166976","https://openalex.org/W1992708211","https://openalex.org/W2380067098","https://openalex.org/W1548152478","https://openalex.org/W2137172615","https://openalex.org/W2112564789","https://openalex.org/W2106247205","https://openalex.org/W3209898720","https://openalex.org/W2135814299"],"abstract_inverted_index":{"Many":[0],"commercial":[1],"benchtop":[2],"impedance":[3,79,92,199,243],"analyzers":[4,244],"are":[5,17,50,59,88],"incapable":[6],"of":[7,76,98,131,139,166,194,206,213],"acquiring":[8],"accurate":[9],"tetrapolar":[10,83,100,236],"measurements,":[11],"when":[12],"large":[13],"electrode":[14,77,106],"contact":[15,78],"impedances":[16],"present,":[18],"as":[19,226],"in":[20,52,69,73,109,203,210],"bioimpedance":[21,84,101,122,208,237],"measurements":[22,93,238],"using":[23],"electrodes":[24,97],"with":[25,61,64,104,137,148,182,197,240],"micrometer-sized":[26],"features.":[27],"External":[28],"front-end":[29,123,147,196,233],"amplifiers":[30,234],"can":[31],"help":[32],"overcome":[33],"this":[34,56,114],"issue":[35],"and":[36,43,118,169,174,176,187,231,241,248],"provide":[37],"high":[38],"common-mode":[39],"rejection":[40],"ratio":[41],"(CMRR)":[42],"input":[44],"impedance.":[45],"Several":[46],"discrete":[47],"component-based":[48],"topologies":[49,142],"proposed":[51,141],"the":[53,74,96,110,127,132,140,154,191,195,198,204,207],"literature.":[54],"In":[55],"article,":[57],"these":[58],"compared":[60],"new":[62],"alternatives":[63],"regard":[65],"to":[66,81,218],"their":[67],"performance":[68],"measuring":[70],"known":[71],"loads":[72,183],"presence":[75],"models,":[80],"emulate":[82],"measurements.":[85],"These":[86],"models":[87,107],"derived":[89],"from":[90,95],"bipolar":[91],"taken":[94],"a":[99,116,145,227],"sensor.":[102],"Comparison":[103],"other":[105],"used":[108],"literature":[111],"established":[112],"that":[113],"is":[115,135,201],"good":[117],"challenging":[119],"model":[120],"for":[121,229,235,245],"amplifier":[124],"evaluation.":[125],"Among":[126],"examined":[128],"amplifiers,":[129],"one":[130,138],"best":[133],"performances":[134],"achieved":[136,159],"based":[143],"on":[144],"custom":[146],"no":[149],"external":[150],"resistors":[151],"(AD8066/AD8130).":[152],"Under":[153],"specific":[155],"testing":[156],"conditions,":[157],"it":[158],"an":[160],"uncalibrated":[161],"worst-case":[162],"absolute":[163],"measurement":[164],"deviation":[165],"4.4%":[167],"magnitude":[168],"4\u00b0":[170],"at":[171,178],"20":[172],"Hz,":[173],"2.2%":[175],"7\u00b0":[177],"1":[179],"MHz":[180],"accordingly":[181],"between":[184],"10":[185,188],"\u03a9":[186],"kg.":[189],"Finally,":[190],"practical":[192],"use":[193],"analyzer":[200],"demonstrated":[202],"characterization":[205],"sensor,":[209],"saline":[211],"solutions":[212],"varying":[214],"conductivities":[215],"(2.5-20":[216],"mS/cm)":[217],"obtain":[219],"its":[220],"cell":[221],"constant.":[222],"This":[223],"article":[224],"serves":[225],"guide":[228],"evaluating":[230],"choosing":[232],"both":[239],"without":[242],"practical/clinical":[246],"applications":[247],"material/sensor":[249],"characterization.":[250]},"counts_by_year":[{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":4},{"year":2021,"cited_by_count":3}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
