{"id":"https://openalex.org/W3008740798","doi":"https://doi.org/10.1109/tim.2020.3007295","title":"Delineation and Analysis of Seismocardiographic Systole and Diastole Profiles","display_name":"Delineation and Analysis of Seismocardiographic Systole and Diastole Profiles","publication_year":2020,"publication_date":"2020-07-06","ids":{"openalex":"https://openalex.org/W3008740798","doi":"https://doi.org/10.1109/tim.2020.3007295","mag":"3008740798"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2020.3007295","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2020.3007295","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["arxiv","crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/2002.10405","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Tilendra Choudhary","orcid":"https://orcid.org/0000-0001-5012-9046"},"institutions":[{"id":"https://openalex.org/I1317621060","display_name":"Indian Institute of Technology Guwahati","ror":"https://ror.org/0022nd079","country_code":"IN","type":"education","lineage":["https://openalex.org/I1317621060"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Tilendra Choudhary","raw_affiliation_strings":["IIT Guwahati, Guwahati, India"],"raw_orcid":"https://orcid.org/0000-0001-5012-9046","affiliations":[{"raw_affiliation_string":"IIT Guwahati, Guwahati, India","institution_ids":["https://openalex.org/I1317621060"]}]},{"author_position":"middle","author":{"id":null,"display_name":"M. K. Bhuyan","orcid":"https://orcid.org/0000-0003-2152-5466"},"institutions":[{"id":"https://openalex.org/I1317621060","display_name":"Indian Institute of Technology Guwahati","ror":"https://ror.org/0022nd079","country_code":"IN","type":"education","lineage":["https://openalex.org/I1317621060"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"M. K. Bhuyan","raw_affiliation_strings":["IIT Guwahati, Guwahati, India"],"raw_orcid":"https://orcid.org/0000-0003-2152-5466","affiliations":[{"raw_affiliation_string":"IIT Guwahati, Guwahati, India","institution_ids":["https://openalex.org/I1317621060"]}]},{"author_position":"last","author":{"id":null,"display_name":"L. N. Sharma","orcid":"https://orcid.org/0000-0002-8233-8982"},"institutions":[{"id":"https://openalex.org/I1317621060","display_name":"Indian Institute of Technology Guwahati","ror":"https://ror.org/0022nd079","country_code":"IN","type":"education","lineage":["https://openalex.org/I1317621060"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"L. N. Sharma","raw_affiliation_strings":["IIT Guwahati, Guwahati, India"],"raw_orcid":"https://orcid.org/0000-0002-8233-8982","affiliations":[{"raw_affiliation_string":"IIT Guwahati, Guwahati, India","institution_ids":["https://openalex.org/I1317621060"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I1317621060"],"apc_list":null,"apc_paid":null,"fwci":0.2207,"has_fulltext":false,"cited_by_count":9,"citation_normalized_percentile":{"value":0.42726998,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"70","issue":null,"first_page":"1","last_page":"8"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.989300012588501,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10065","display_name":"Atrial Fibrillation Management and Outcomes","score":0.0013000000035390258,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12419","display_name":"Phonocardiography and Auscultation Techniques","score":0.0008999999845400453,"subfield":{"id":"https://openalex.org/subfields/2740","display_name":"Pulmonary and Respiratory Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fiducial-marker","display_name":"Fiducial marker","score":0.732699990272522},{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.660099983215332},{"id":"https://openalex.org/keywords/diastole","display_name":"Diastole","score":0.544700026512146},{"id":"https://openalex.org/keywords/envelope","display_name":"Envelope (radar)","score":0.5328999757766724},{"id":"https://openalex.org/keywords/systole","display_name":"Systole","score":0.5249999761581421},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.4700999855995178},{"id":"https://openalex.org/keywords/signal-processing","display_name":"Signal processing","score":0.4537000060081482},{"id":"https://openalex.org/keywords/pattern-recognition","display_name":"Pattern recognition (psychology)","score":0.38119998574256897}],"concepts":[{"id":"https://openalex.org/C173974348","wikidata":"https://www.wikidata.org/wiki/Q1469893","display_name":"Fiducial marker","level":2,"score":0.732699990272522},{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.660099983215332},{"id":"https://openalex.org/C57900726","wikidata":"https://www.wikidata.org/wiki/Q492905","display_name":"Diastole","level":3,"score":0.544700026512146},{"id":"https://openalex.org/C65155139","wikidata":"https://www.wikidata.org/wiki/Q5380912","display_name":"Envelope (radar)","level":3,"score":0.5328999757766724},{"id":"https://openalex.org/C169554166","wikidata":"https://www.wikidata.org/wiki/Q496359","display_name":"Systole","level":4,"score":0.5249999761581421},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.4700999855995178},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.4537000060081482},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3971000015735626},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.38119998574256897},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3758000135421753},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.35589998960494995},{"id":"https://openalex.org/C39300077","wikidata":"https://www.wikidata.org/wiki/Q9530","display_name":"Breathing","level":2,"score":0.3357999920845032},{"id":"https://openalex.org/C2777402240","wikidata":"https://www.wikidata.org/wiki/Q6783436","display_name":"Masking (illustration)","level":2,"score":0.32280001044273376},{"id":"https://openalex.org/C177264268","wikidata":"https://www.wikidata.org/wiki/Q1514741","display_name":"Set (abstract data type)","level":2,"score":0.3165999948978424},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.2971999943256378},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.2890999913215637},{"id":"https://openalex.org/C2779055095","wikidata":"https://www.wikidata.org/wiki/Q162339","display_name":"Stethoscope","level":2,"score":0.2720000147819519},{"id":"https://openalex.org/C58489278","wikidata":"https://www.wikidata.org/wiki/Q1172284","display_name":"Data set","level":2,"score":0.27090001106262207},{"id":"https://openalex.org/C99398487","wikidata":"https://www.wikidata.org/wiki/Q257319","display_name":"Cardiac cycle","level":2,"score":0.26330000162124634},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.2547000050544739}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tim.2020.3007295","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2020.3007295","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:arXiv.org:2002.10405","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2002.10405","pdf_url":"https://arxiv.org/pdf/2002.10405","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:2002.10405","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2002.10405","pdf_url":"https://arxiv.org/pdf/2002.10405","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W1569781326","https://openalex.org/W1937931689","https://openalex.org/W1968379679","https://openalex.org/W1971808924","https://openalex.org/W1988183757","https://openalex.org/W1990956587","https://openalex.org/W2007729863","https://openalex.org/W2036806998","https://openalex.org/W2041563242","https://openalex.org/W2087385144","https://openalex.org/W2115340664","https://openalex.org/W2148325642","https://openalex.org/W2247575651","https://openalex.org/W2255363334","https://openalex.org/W2295737948","https://openalex.org/W2530643226","https://openalex.org/W2538315610","https://openalex.org/W2789137192","https://openalex.org/W2803038464","https://openalex.org/W2896674935","https://openalex.org/W2903144141","https://openalex.org/W2909637210","https://openalex.org/W2910678199","https://openalex.org/W2933425445","https://openalex.org/W2975533848","https://openalex.org/W3004205391","https://openalex.org/W6661266497","https://openalex.org/W6675264869","https://openalex.org/W6754235555"],"related_works":[],"abstract_inverted_index":{"Precise":[0],"estimation":[1,100],"of":[2,5,33,40,61,87,93,101,105,142],"fiducial":[3,56,103],"points":[4,32,57,104],"a":[6,11,47,62,71],"seismocardiogram":[7],"(SCG)":[8],"signal":[9,36],"is":[10,44,80,97],"challenging":[12],"problem":[13],"for":[14,99],"its":[15],"clinical":[16],"usage.":[17],"Delineation":[18],"techniques":[19],"proposed":[20,67,81,144],"in":[21],"the":[22,29,59,84,88,140,143,155],"existing":[23],"literature":[24],"do":[25],"not":[26],"estimate":[27,83],"all":[28],"clinically":[30],"significant":[31],"an":[34,76],"SCG":[35,106,119,127],"simultaneously.":[37],"The":[38,66],"aim":[39],"this":[41],"research":[42],"work":[43],"to":[45,50,82,153],"propose":[46],"delineation":[48,68],"framework":[49],"identify":[51],"various":[52],"systole":[53],"and":[54,75,120,136,160],"diastole":[55,116],"with":[58],"help":[60],"photoplethysmogram":[63],"(PPG)":[64],"signal.":[65,90],"method":[69],"processes":[70],"wavelet-based":[72],"scalographic":[73],"PPG,":[74],"envelope":[77],"construction":[78],"scheme":[79],"prominent":[85],"peaks":[86],"PPG":[89],"A":[91],"set":[92],"amplitude-histogram-based":[94],"decision":[95,121],"rules":[96],"developed":[98],"three":[102,109],"diastole.":[107],"Subsequently,":[108],"systolic":[110],"phases":[111],"are":[112,151],"detected":[113],"by":[114],"applying":[115],"masking":[117],"on":[118,125],"rules.":[122],"Experimental":[123],"results":[124],"real-time":[126],"signals":[128],"acquired":[129],"from":[130],"our":[131],"designed":[132],"data":[133],"acquisition":[134],"circuitry":[135],"their":[137],"analysis":[138],"shows":[139],"effectiveness":[141],"scheme.":[145],"In":[146],"addition,":[147],"these":[148],"estimated":[149],"parameters":[150],"analyzed":[152],"show":[154],"discrimination":[156],"between":[157],"normal":[158],"breathing":[159],"breathlessness":[161],"conditions.":[162]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2021,"cited_by_count":2}],"updated_date":"2026-08-19T15:00:24.278416","created_date":"2020-03-06T00:00:00"}
