{"id":"https://openalex.org/W2996929090","doi":"https://doi.org/10.1109/tim.2019.2963508","title":"Reflective Photoplethysmography Acquisition Platform With Monitoring Modules and Noninvasive Blood Pressure Calculation","display_name":"Reflective Photoplethysmography Acquisition Platform With Monitoring Modules and Noninvasive Blood Pressure Calculation","publication_year":2020,"publication_date":"2020-01-01","ids":{"openalex":"https://openalex.org/W2996929090","doi":"https://doi.org/10.1109/tim.2019.2963508","mag":"2996929090"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2019.2963508","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2019.2963508","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5049749703","display_name":"Mauricio P. Dal Pont","orcid":"https://orcid.org/0000-0002-2820-2988"},"institutions":[{"id":"https://openalex.org/I4104125","display_name":"Universidade Federal de Santa Catarina","ror":"https://ror.org/041akq887","country_code":"BR","type":"education","lineage":["https://openalex.org/I4104125"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Mauricio P. Dal Pont","raw_affiliation_strings":["Federal University of Santa Catarina, Florian\u00f3polis, Brazil"],"raw_orcid":"https://orcid.org/0000-0002-2820-2988","affiliations":[{"raw_affiliation_string":"Federal University of Santa Catarina, Florian\u00f3polis, Brazil","institution_ids":["https://openalex.org/I4104125"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5046051474","display_name":"Jefferson Luiz Brum Marques","orcid":"https://orcid.org/0000-0001-8910-4735"},"institutions":[{"id":"https://openalex.org/I4104125","display_name":"Universidade Federal de Santa Catarina","ror":"https://ror.org/041akq887","country_code":"BR","type":"education","lineage":["https://openalex.org/I4104125"]}],"countries":["BR"],"is_corresponding":false,"raw_author_name":"Jefferson L. B. Marques","raw_affiliation_strings":["Federal University of Santa Catarina, Florian\u00f3polis, Brazil"],"raw_orcid":"https://orcid.org/0000-0001-8910-4735","affiliations":[{"raw_affiliation_string":"Federal University of Santa Catarina, Florian\u00f3polis, Brazil","institution_ids":["https://openalex.org/I4104125"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4104125"],"apc_list":null,"apc_paid":null,"fwci":0.7843,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.67532377,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":98},"biblio":{"volume":"69","issue":"8","first_page":"5649","last_page":"5657"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.9983999729156494,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/photoplethysmogram","display_name":"Photoplethysmogram","score":0.9127031564712524},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.5016734600067139},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4660934507846832},{"id":"https://openalex.org/keywords/pressure-measurement","display_name":"Pressure measurement","score":0.44865578413009644},{"id":"https://openalex.org/keywords/blood-pressure","display_name":"Blood pressure","score":0.4329376518726349},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.27557310461997986},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.15466970205307007},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.14306065440177917},{"id":"https://openalex.org/keywords/wireless","display_name":"Wireless","score":0.13342642784118652}],"concepts":[{"id":"https://openalex.org/C116390426","wikidata":"https://www.wikidata.org/wiki/Q7187885","display_name":"Photoplethysmogram","level":3,"score":0.9127031564712524},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.5016734600067139},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4660934507846832},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.44865578413009644},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.4329376518726349},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27557310461997986},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.15466970205307007},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.14306065440177917},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.13342642784118652},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2019.2963508","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2019.2963508","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":33,"referenced_works":["https://openalex.org/W1784479090","https://openalex.org/W1971877713","https://openalex.org/W1988770599","https://openalex.org/W2040137929","https://openalex.org/W2055999471","https://openalex.org/W2066932506","https://openalex.org/W2076420009","https://openalex.org/W2083872334","https://openalex.org/W2088204643","https://openalex.org/W2096467866","https://openalex.org/W2106499015","https://openalex.org/W2111481778","https://openalex.org/W2116988824","https://openalex.org/W2133750711","https://openalex.org/W2137712901","https://openalex.org/W2143550175","https://openalex.org/W2162800060","https://openalex.org/W2171767692","https://openalex.org/W2313564472","https://openalex.org/W2538561053","https://openalex.org/W2545463471","https://openalex.org/W2576387397","https://openalex.org/W2755048715","https://openalex.org/W2790723868","https://openalex.org/W2801417501","https://openalex.org/W2827814385","https://openalex.org/W2898688633","https://openalex.org/W2943612909","https://openalex.org/W2944130429","https://openalex.org/W3099743694","https://openalex.org/W4250928742","https://openalex.org/W6647540373","https://openalex.org/W6681030710"],"related_works":["https://openalex.org/W2156628018","https://openalex.org/W3067882053","https://openalex.org/W2532439670","https://openalex.org/W2794656031","https://openalex.org/W1976634402","https://openalex.org/W4200597674","https://openalex.org/W4210540536","https://openalex.org/W2021674224","https://openalex.org/W2079995064","https://openalex.org/W2974043559"],"abstract_inverted_index":{"Modularity":[0],"is":[1,20,46,95],"one":[2],"of":[3,8,12,86,113,174,196,222,243],"the":[4,9,24,32,42,57,71,75,82,114,120,142,156,172,175,186,191,194,220,233],"most":[5],"important":[6],"aspects":[7],"continuous":[10],"development":[11,221,242],"a":[13,16,60,103,128,136,152,223,244],"system.":[14],"With":[15],"modular":[17,61,224],"platform,":[18],"it":[19],"possible":[21],"to":[22,80,101,130,154],"scale":[23],"functionalities,":[25],"adding":[26],"more":[27],"features":[28],"or":[29,117],"keeping":[30],"just":[31],"needed":[33],"ones.":[34],"A":[35],"very":[36],"robust":[37],"and":[38,90,162,241],"effective":[39],"solution":[40],"for":[41,59,77,193],"real-time":[43],"monitoring":[44,49,226],"problem":[45],"an":[47,87,146,166,206,254],"automotive":[48],"system":[50,227],"whose":[51],"architecture":[52],"will":[53],"be":[54],"used":[55],"as":[56],"base":[58],"photoplethysmography":[62],"(PPG)":[63],"acquisition":[64,68,93],"platform.":[65],"The":[66,92,200],"PPG":[67,143,161],"platform":[69,94,176],"uses":[70],"reflective":[72],"configuration":[73],"on":[74,141,229,232,239,249],"wrist":[76],"u-health":[78],"applications":[79],"allow":[81],"medical":[83],"data":[84],"management":[85],"individual":[88],"anytime":[89],"anywhere.":[91],"equipped":[96],"with":[97,145,160],"LED":[98],"voltage":[99],"control":[100],"capture":[102],"wave":[104],"morphology":[105],"without":[106,163,203,251],"any":[107],"interference":[108],"from":[109,119,165,253],"skin":[110],"color,":[111],"thickness":[112],"fat":[115],"layer,":[116],"stiffness":[118],"subject's":[121],"artery":[122],"walls.":[123],"This":[124],"article":[125],"also":[126,150,159],"provides":[127],"technique":[129,153],"obtain":[131,155],"blood":[132],"pressure":[133],"(BP)":[134],"in":[135,177,182],"noninvasive":[137,179],"way,":[138],"based":[139,228,238,248],"only":[140],"signal":[144],"initial":[147],"calibration.":[148],"We":[149],"study":[151],"BP":[157,180,201,235,245],"parameter,":[158],"calibration":[164,204,252],"auxiliary":[167,207],"device.":[168,256],"Our":[169],"results":[170],"proved":[171],"success":[173],"capturing":[178],"calculation":[181,202,236],"real":[183],"time,":[184],"achieving":[185],"tolerance":[187],"errors":[188],"allowed":[189],"by":[190,205],"Association":[192],"Advancement":[195],"Medical":[197],"Instrumentation":[198],"(AAMI).":[199],"device":[208],"showed":[209],"promising":[210],"results,":[211],"but":[212],"further":[213],"studies":[214],"are":[215,219],"needed.":[216],"Main":[217],"contributions":[218],"human":[225],"PPG;":[230,240],"improvements":[231],"existing":[234],"algorithm":[237,247],"estimation":[246],"PPG,":[250],"external":[255]},"counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":4},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":3}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
