{"id":"https://openalex.org/W2905043871","doi":"https://doi.org/10.1109/tim.2018.2884041","title":"Motion-Artifact Reduction in Capacitive Heart-Rate Measurements by Adaptive Filtering","display_name":"Motion-Artifact Reduction in Capacitive Heart-Rate Measurements by Adaptive Filtering","publication_year":2018,"publication_date":"2018-12-11","ids":{"openalex":"https://openalex.org/W2905043871","doi":"https://doi.org/10.1109/tim.2018.2884041","mag":"2905043871"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2018.2884041","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2018.2884041","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://pure.tue.nl/ws/files/118222793/Manuscript.pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033083912","display_name":"Lin Xu","orcid":"https://orcid.org/0000-0001-5777-1496"},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":true,"raw_author_name":"Lin Xu","raw_affiliation_strings":["Signal Processing System Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Signal Processing System Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025104488","display_name":"Chiara Rabotti","orcid":"https://orcid.org/0000-0001-8865-1219"},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Chiara Rabotti","raw_affiliation_strings":["Signal Processing System Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Signal Processing System Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100726566","display_name":"Yijing Zhang","orcid":"https://orcid.org/0000-0002-6931-0424"},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Yijing Zhang","raw_affiliation_strings":["Integrated Circuits Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Integrated Circuits Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5067991347","display_name":"Sotir Ouzounov","orcid":"https://orcid.org/0000-0003-1961-2317"},"institutions":[{"id":"https://openalex.org/I4210122849","display_name":"Philips (Netherlands)","ror":"https://ror.org/02p2bgp27","country_code":"NL","type":"company","lineage":["https://openalex.org/I4210122849"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Sotir Ouzounov","raw_affiliation_strings":["Micro Systems and Devices Group, Philips Research Europe, Eindhoven, AE, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Micro Systems and Devices Group, Philips Research Europe, Eindhoven, AE, The Netherlands","institution_ids":["https://openalex.org/I4210122849"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5010280308","display_name":"Pieter Harpe","orcid":"https://orcid.org/0000-0002-6542-0001"},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Pieter J. A. Harpe","raw_affiliation_strings":["Integrated Circuits Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Integrated Circuits Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5050399847","display_name":"Massimo Mischi","orcid":"https://orcid.org/0000-0002-1179-5385"},"institutions":[{"id":"https://openalex.org/I83019370","display_name":"Eindhoven University of Technology","ror":"https://ror.org/02c2kyt77","country_code":"NL","type":"education","lineage":["https://openalex.org/I83019370"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Massimo Mischi","raw_affiliation_strings":["Signal Processing System Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Signal Processing System Group, Eindhoven University of Technology, Eindhoven, AP, The Netherlands","institution_ids":["https://openalex.org/I83019370"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":["https://openalex.org/A5033083912"],"corresponding_institution_ids":["https://openalex.org/I83019370"],"apc_list":null,"apc_paid":null,"fwci":2.7317,"has_fulltext":true,"cited_by_count":40,"citation_normalized_percentile":{"value":0.91655503,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"68","issue":"10","first_page":"4085","last_page":"4093"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9994000196456909,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10745","display_name":"Heart Rate Variability and Autonomic Control","score":0.996399998664856,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.8146921396255493},{"id":"https://openalex.org/keywords/signal","display_name":"SIGNAL (programming language)","score":0.5667219161987305},{"id":"https://openalex.org/keywords/adaptive-filter","display_name":"Adaptive filter","score":0.5576653480529785},{"id":"https://openalex.org/keywords/capacitance","display_name":"Capacitance","score":0.5495985746383667},{"id":"https://openalex.org/keywords/capacitive-coupling","display_name":"Capacitive coupling","score":0.5408288836479187},{"id":"https://openalex.org/keywords/noise","display_name":"Noise (video)","score":0.5355932712554932},{"id":"https://openalex.org/keywords/acceleration","display_name":"Acceleration","score":0.4841773808002472},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4771503806114197},{"id":"https://openalex.org/keywords/remote-patient-monitoring","display_name":"Remote patient monitoring","score":0.46982312202453613},{"id":"https://openalex.org/keywords/artifact","display_name":"Artifact (error)","score":0.45469796657562256},{"id":"https://openalex.org/keywords/filter","display_name":"Filter (signal processing)","score":0.4271222949028015},{"id":"https://openalex.org/keywords/noise-reduction","display_name":"Noise reduction","score":0.42681941390037537},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.40411055088043213},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.3479928970336914},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2532242238521576},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.2470226287841797},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.20871344208717346},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.13961035013198853},{"id":"https://openalex.org/keywords/medicine","display_name":"Medicine","score":0.09231939911842346},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.08496370911598206},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.07682260870933533}],"concepts":[{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.8146921396255493},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.5667219161987305},{"id":"https://openalex.org/C102248274","wikidata":"https://www.wikidata.org/wiki/Q168388","display_name":"Adaptive filter","level":2,"score":0.5576653480529785},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.5495985746383667},{"id":"https://openalex.org/C68278764","wikidata":"https://www.wikidata.org/wiki/Q444167","display_name":"Capacitive coupling","level":3,"score":0.5408288836479187},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.5355932712554932},{"id":"https://openalex.org/C117896860","wikidata":"https://www.wikidata.org/wiki/Q11376","display_name":"Acceleration","level":2,"score":0.4841773808002472},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4771503806114197},{"id":"https://openalex.org/C175079658","wikidata":"https://www.wikidata.org/wiki/Q7312165","display_name":"Remote patient monitoring","level":2,"score":0.46982312202453613},{"id":"https://openalex.org/C2779010991","wikidata":"https://www.wikidata.org/wiki/Q2720909","display_name":"Artifact (error)","level":2,"score":0.45469796657562256},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.4271222949028015},{"id":"https://openalex.org/C163294075","wikidata":"https://www.wikidata.org/wiki/Q581861","display_name":"Noise reduction","level":2,"score":0.42681941390037537},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.40411055088043213},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.3479928970336914},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2532242238521576},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.2470226287841797},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.20871344208717346},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.13961035013198853},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.09231939911842346},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.08496370911598206},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.07682260870933533},{"id":"https://openalex.org/C115961682","wikidata":"https://www.wikidata.org/wiki/Q860623","display_name":"Image (mathematics)","level":2,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C74650414","wikidata":"https://www.wikidata.org/wiki/Q11397","display_name":"Classical mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0}],"mesh":[],"locations_count":6,"locations":[{"id":"doi:10.1109/tim.2018.2884041","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2018.2884041","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:pure.tue.nl:openaire_cris_publications/fb292da4-9fec-4ac2-8421-caa57f980562","is_oa":true,"landing_page_url":"https://research.tue.nl/en/publications/fb292da4-9fec-4ac2-8421-caa57f980562","pdf_url":"https://pure.tue.nl/ws/files/118222793/Manuscript.pdf","source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Xu, L, Rabotti, C, Zhang, Y, Ouzounov, S, Harpe, P J A & Mischi, M 2019, 'Motion-artifact reduction in capacitive heart-rate measurements by adaptive filtering', IEEE Transactions on Instrumentation and Measurement, vol. 68, no. 10, 8573141, pp. 4085-4093. https://doi.org/10.1109/TIM.2018.2884041","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:908096","is_oa":false,"landing_page_url":"http://library.tue.nl/csp/dare/LinkToRepository.csp?recordnumber=908096","pdf_url":null,"source":{"id":"https://openalex.org/S4406923046","display_name":"TU/e Research Portal (Eindhoven University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN:0018-9456","raw_type":"Article / Letter to the editor"},{"id":"pmh:oai:library.tue.nl:908096","is_oa":false,"landing_page_url":"http://repository.tue.nl/908096","pdf_url":null,"source":{"id":"https://openalex.org/S4406923046","display_name":"TU/e Research Portal (Eindhoven University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN:0018-9456","raw_type":"Article / Letter to the editor"},{"id":"pmh:oai:pure.tue.nl:publications/fb292da4-9fec-4ac2-8421-caa57f980562","is_oa":true,"landing_page_url":"http://www.scopus.com/inward/record.url?scp=85058642390&partnerID=8YFLogxK","pdf_url":null,"source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Xu, L, Rabotti, C, Zhang, Y, Ouzounov, S, Harpe, P J A & Mischi, M 2019, 'Motion-artifact reduction in capacitive heart-rate measurements by adaptive filtering', IEEE Transactions on Instrumentation and Measurement, vol. 68, no. 10, 8573141, pp. 4085-4093. https://doi.org/10.1109/TIM.2018.2884041","raw_type":"info:eu-repo/semantics/publishedVersion"},{"id":"pmh:tue:oai:pure.tue.nl:publications/fb292da4-9fec-4ac2-8421-caa57f980562","is_oa":true,"landing_page_url":"https://research.tue.nl/nl/publications/fb292da4-9fec-4ac2-8421-caa57f980562","pdf_url":null,"source":{"id":"https://openalex.org/S4306401843","display_name":"Data Archiving and Networked Services (DANS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I1322597698","host_organization_name":"Royal Netherlands Academy of Arts and Sciences","host_organization_lineage":["https://openalex.org/I1322597698"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement, 68(10):8573141, 4085 - 4093. Institute of Electrical and Electronics Engineers","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:pure.tue.nl:openaire_cris_publications/fb292da4-9fec-4ac2-8421-caa57f980562","is_oa":true,"landing_page_url":"https://research.tue.nl/en/publications/fb292da4-9fec-4ac2-8421-caa57f980562","pdf_url":"https://pure.tue.nl/ws/files/118222793/Manuscript.pdf","source":{"id":"https://openalex.org/S4406922641","display_name":"TU/e Research Portal","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Xu, L, Rabotti, C, Zhang, Y, Ouzounov, S, Harpe, P J A & Mischi, M 2019, 'Motion-artifact reduction in capacitive heart-rate measurements by adaptive filtering', IEEE Transactions on Instrumentation and Measurement, vol. 68, no. 10, 8573141, pp. 4085-4093. https://doi.org/10.1109/TIM.2018.2884041","raw_type":"info:eu-repo/semantics/publishedVersion"},"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321800","display_name":"Nederlandse Organisatie voor Wetenschappelijk Onderzoek","ror":"https://ror.org/04jsz6e67"},{"id":"https://openalex.org/F4320334893","display_name":"Stichting voor de Technische Wetenschappen","ror":"https://ror.org/057tq3593"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W2905043871.pdf","grobid_xml":"https://content.openalex.org/works/W2905043871.grobid-xml"},"referenced_works_count":36,"referenced_works":["https://openalex.org/W25202913","https://openalex.org/W94431762","https://openalex.org/W608933645","https://openalex.org/W621251951","https://openalex.org/W1882885596","https://openalex.org/W1995140466","https://openalex.org/W2003109807","https://openalex.org/W2027562582","https://openalex.org/W2029299375","https://openalex.org/W2035563303","https://openalex.org/W2038551397","https://openalex.org/W2050259033","https://openalex.org/W2071976867","https://openalex.org/W2075224393","https://openalex.org/W2075226977","https://openalex.org/W2075763398","https://openalex.org/W2085063828","https://openalex.org/W2089349857","https://openalex.org/W2089475953","https://openalex.org/W2103089564","https://openalex.org/W2109340646","https://openalex.org/W2110075977","https://openalex.org/W2125154859","https://openalex.org/W2125290998","https://openalex.org/W2126390573","https://openalex.org/W2136177393","https://openalex.org/W2152846380","https://openalex.org/W2156736318","https://openalex.org/W2163222801","https://openalex.org/W2166548670","https://openalex.org/W2261658559","https://openalex.org/W2735000467","https://openalex.org/W2886367177","https://openalex.org/W3083977607","https://openalex.org/W6601042469","https://openalex.org/W6603822822"],"related_works":["https://openalex.org/W52840052","https://openalex.org/W3102847316","https://openalex.org/W2768092448","https://openalex.org/W2895758062","https://openalex.org/W2048683560","https://openalex.org/W2044770004","https://openalex.org/W1966070768","https://openalex.org/W1994341348","https://openalex.org/W2953512238","https://openalex.org/W4387574169"],"abstract_inverted_index":{"Electrocardiography":[0],"(ECG)":[1],"measurements":[2,13,50],"are":[3,40,51],"essential":[4],"components":[5],"in":[6,72,93,127,143,156,221],"clinical":[7],"diagnosis":[8],"and":[9,25,175,178],"monitoring.":[10,46],"Conventional":[11],"ECG":[12,33,49,73,101,130,188,219],"produce":[14],"discomfort":[15],"to":[16,20,59,132,214],"the":[17,21,86,113,119,144,149,157,181,194],"patients":[18],"due":[19,58,131],"use":[22],"of":[23,201,217],"gel":[24],"direct":[26],"skin":[27],"contact.":[28],"Capacitive":[29],"electrodes":[30],"can":[31,160],"measure":[32],"signals":[34,220],"through":[35],"an":[36],"isolation":[37],"layer;":[38],"they":[39],"especially":[41],"suitable":[42],"for":[43,69,85,109,163],"long-term":[44],"ambulatory":[45,94,222],"However,":[47],"capacitive":[48,100,129,218],"severely":[52],"affected":[53],"by":[54,80,173,193],"motion":[55],"artifacts":[56],"(MAs)":[57],"variable":[60],"coupling":[61,134,158],"distance.":[62],"Adaptive":[63],"filtering":[64],"has":[65],"been":[66],"widely":[67],"used":[68],"MA":[70,110,165,206],"reduction":[71],"measurements.":[74],"Unfortunately,":[75],"a":[76,103,128,151,198],"reference":[77,114,152],"signal":[78,115,153],"recorded":[79],"additional":[81],"sensors":[82],"is":[83,107,116,124],"required":[84],"existing":[87],"adaptive-filtering":[88,183],"methods,":[89],"limiting":[90],"their":[91],"applicability":[92],"settings.":[95,223],"In":[96],"this":[97],"paper":[98],"on":[99],"recordings,":[102],"novel":[104],"adaptivefiltering":[105],"method":[106,169,196,210],"proposed":[108,168,195,209],"removal,":[111],"where":[112],"extracted":[117,162],"from":[118],"power-line":[120],"interference":[121],"(PLI).":[122],"PLI":[123,145],"particularly":[125],"evident":[126],"unbalanced":[133],"capacitance.":[135],"Along":[136],"with":[137,180,197],"MAs,":[138],"electrode":[139],"movement":[140],"causes":[141],"variations":[142,155],"amplitude.":[146],"By":[147],"demodulating":[148],"PLI,":[150],"reflecting":[154],"capacitance":[159],"be":[161],"adaptive":[164],"removal.":[166,207],"The":[167,208],"was":[170,191],"evaluated":[171],"both":[172],"simulations":[174],"real":[176],"data":[177],"compared":[179],"acceleration-based":[182],"method.":[184],"Comparable":[185],"or":[186],"higher":[187],"signal-to-noise":[189],"ratio":[190],"achieved":[192],"computational":[199],"cost":[200],"79":[202],"\u03bcs/iteration,":[203],"indicating":[204],"effective":[205],"may,":[211],"therefore,":[212],"lead":[213],"improved":[215],"analysis":[216]},"counts_by_year":[{"year":2025,"cited_by_count":5},{"year":2024,"cited_by_count":10},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":9},{"year":2019,"cited_by_count":5}],"updated_date":"2026-04-14T08:04:32.555800","created_date":"2025-10-10T00:00:00"}
