{"id":"https://openalex.org/W2619173763","doi":"https://doi.org/10.1109/tim.2017.2700118","title":"Assessing the Feasibility of the Use of Video Motion Magnification for Measuring Microdisplacements","display_name":"Assessing the Feasibility of the Use of Video Motion Magnification for Measuring Microdisplacements","publication_year":2017,"publication_date":"2017-05-22","ids":{"openalex":"https://openalex.org/W2619173763","doi":"https://doi.org/10.1109/tim.2017.2700118","mag":"2619173763"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2017.2700118","is_oa":false,"landing_page_url":"http://doi.org/10.1109/tim.2017.2700118","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5038046365","display_name":"Mateusz Popek","orcid":"https://orcid.org/0000-0002-5490-3585"},"institutions":[{"id":"https://openalex.org/I11923345","display_name":"Wroc\u0142aw University of Science and Technology","ror":"https://ror.org/008fyn775","country_code":"PL","type":"education","lineage":["https://openalex.org/I11923345"]},{"id":"https://openalex.org/I686019","display_name":"AGH University of Krakow","ror":"https://ror.org/00bas1c41","country_code":"PL","type":"education","lineage":["https://openalex.org/I686019"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Mateusz P. Popek","raw_affiliation_strings":["Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroc\u0142aw, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroc\u0142aw, Poland","institution_ids":["https://openalex.org/I11923345","https://openalex.org/I686019"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5012125539","display_name":"Monika E. Danielewska","orcid":"https://orcid.org/0000-0001-8532-1927"},"institutions":[{"id":"https://openalex.org/I11923345","display_name":"Wroc\u0142aw University of Science and Technology","ror":"https://ror.org/008fyn775","country_code":"PL","type":"education","lineage":["https://openalex.org/I11923345"]},{"id":"https://openalex.org/I686019","display_name":"AGH University of Krakow","ror":"https://ror.org/00bas1c41","country_code":"PL","type":"education","lineage":["https://openalex.org/I686019"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"Monika E. Danielewska","raw_affiliation_strings":["Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroc\u0142aw, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroc\u0142aw, Poland","institution_ids":["https://openalex.org/I11923345","https://openalex.org/I686019"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5053470224","display_name":"D. Robert Iskander","orcid":"https://orcid.org/0000-0002-5962-6206"},"institutions":[{"id":"https://openalex.org/I11923345","display_name":"Wroc\u0142aw University of Science and Technology","ror":"https://ror.org/008fyn775","country_code":"PL","type":"education","lineage":["https://openalex.org/I11923345"]},{"id":"https://openalex.org/I686019","display_name":"AGH University of Krakow","ror":"https://ror.org/00bas1c41","country_code":"PL","type":"education","lineage":["https://openalex.org/I686019"]}],"countries":["PL"],"is_corresponding":false,"raw_author_name":"D. Robert Iskander","raw_affiliation_strings":["Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroc\u0142aw, Poland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, Wroc\u0142aw, Poland","institution_ids":["https://openalex.org/I11923345","https://openalex.org/I686019"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4386,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.64863756,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"66","issue":"9","first_page":"2329","last_page":"2336"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10205","display_name":"Advanced Fiber Optic Sensors","score":0.9940000176429749,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10205","display_name":"Advanced Fiber Optic Sensors","score":0.9940000176429749,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9934999942779541,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13049","display_name":"Surface Roughness and Optical Measurements","score":0.9901000261306763,"subfield":{"id":"https://openalex.org/subfields/2206","display_name":"Computational Mechanics"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/magnification","display_name":"Magnification","score":0.5808074474334717},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5214080810546875},{"id":"https://openalex.org/keywords/computer-vision","display_name":"Computer vision","score":0.4722900986671448},{"id":"https://openalex.org/keywords/motion","display_name":"Motion (physics)","score":0.4197889566421509},{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.4024297297000885},{"id":"https://openalex.org/keywords/computer-graphics","display_name":"Computer graphics (images)","score":0.37676578760147095}],"concepts":[{"id":"https://openalex.org/C4144372","wikidata":"https://www.wikidata.org/wiki/Q675287","display_name":"Magnification","level":2,"score":0.5808074474334717},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5214080810546875},{"id":"https://openalex.org/C31972630","wikidata":"https://www.wikidata.org/wiki/Q844240","display_name":"Computer vision","level":1,"score":0.4722900986671448},{"id":"https://openalex.org/C104114177","wikidata":"https://www.wikidata.org/wiki/Q79782","display_name":"Motion (physics)","level":2,"score":0.4197889566421509},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.4024297297000885},{"id":"https://openalex.org/C121684516","wikidata":"https://www.wikidata.org/wiki/Q7600677","display_name":"Computer graphics (images)","level":1,"score":0.37676578760147095}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2017.2700118","is_oa":false,"landing_page_url":"http://doi.org/10.1109/tim.2017.2700118","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320334266","display_name":"Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology","ror":null}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":24,"referenced_works":["https://openalex.org/W1932561330","https://openalex.org/W1972749233","https://openalex.org/W1977985044","https://openalex.org/W1978183255","https://openalex.org/W1990370049","https://openalex.org/W1998391547","https://openalex.org/W2011115710","https://openalex.org/W2029783581","https://openalex.org/W2032001526","https://openalex.org/W2048080198","https://openalex.org/W2051162467","https://openalex.org/W2098393311","https://openalex.org/W2129966346","https://openalex.org/W2133059825","https://openalex.org/W2134813104","https://openalex.org/W2140500332","https://openalex.org/W2142953531","https://openalex.org/W2145131129","https://openalex.org/W2156435826","https://openalex.org/W2159333782","https://openalex.org/W2165863219","https://openalex.org/W2172266547","https://openalex.org/W2294052718","https://openalex.org/W6648075049"],"related_works":["https://openalex.org/W2755342338","https://openalex.org/W1891287906","https://openalex.org/W2036807459","https://openalex.org/W2775347418","https://openalex.org/W1969923398","https://openalex.org/W2772917594","https://openalex.org/W2166024367","https://openalex.org/W3116076068","https://openalex.org/W2229312674","https://openalex.org/W2058170566"],"abstract_inverted_index":{"There":[0],"are":[1],"different":[2],"techniques":[3],"for":[4,26,137],"measuring":[5,27,138],"microdisplacements.":[6],"The":[7,72,118,128],"purpose":[8],"of":[9,18,49,55,74,114,121,144],"this":[10],"paper":[11],"was":[12],"to":[13,45,101,134],"ascertain":[14],"whether":[15],"a":[16,41,112],"method":[17,66],"video":[19,33],"motion":[20],"magnification":[21],"(VMM)":[22],"can":[23,91],"be":[24],"used":[25,44],"such":[28],"displacements.":[29],"For":[30],"this,":[31],"standard":[32],"devices":[34],"(a":[35],"digital":[36],"single-lens":[37],"reflex":[38],"camera":[39],"and":[40,52,140,148],"webcam)":[42],"were":[43,59,125],"record":[46],"subtle":[47],"movements":[48],"an":[50,62,132],"object,":[51],"the":[53,56,75,84,89,96,122,142],"results":[54,73],"VMM":[57,76,129],"technique":[58,77,130],"contrasted":[60],"with":[61,80],"air-coupled":[63],"ultrasonic":[64,85],"sensing":[65],"that":[67,88],"could":[68],"achieve":[69],"submicrometer":[70],"accuracy.":[71],"highly":[78],"correlate":[79],"those":[81],"achieved":[82],"using":[83],"sensor,":[86],"showing":[87],"former":[90],"accurately":[92],"measure":[93],"displacements":[94],"in":[95],"range":[97],"from":[98,111],"about":[99,115],"5":[100],"40":[102],"$\\mu":[106],"\\text{m}$":[107],"distance":[113],"1":[116],"m.":[117],"temporal":[119],"characteristics":[120],"moving":[123],"object":[124],"well":[126],"preserved.":[127],"is":[131],"alternative":[133],"other":[135],"modalities":[136],"microdisplacements":[139],"has":[141],"advantage":[143],"being":[145],"noncontact,":[146],"long-range,":[147],"relatively":[149],"low-cost.":[150]},"counts_by_year":[{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":2},{"year":2017,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}
