{"id":"https://openalex.org/W2516616767","doi":"https://doi.org/10.1109/tim.2017.2687138","title":"Experimental Setup to Compare Measurements and Numerical Simulations in Magnetic Resonance Imaging RF Dosimetry","display_name":"Experimental Setup to Compare Measurements and Numerical Simulations in Magnetic Resonance Imaging RF Dosimetry","publication_year":2017,"publication_date":"2017-04-12","ids":{"openalex":"https://openalex.org/W2516616767","doi":"https://doi.org/10.1109/tim.2017.2687138","mag":"2516616767"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2017.2687138","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2017.2687138","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://openresearch.lsbu.ac.uk/download/565ed363ed56eee09c107ceb809bfeb7bcadff4caac01521922ae86e623cb0f7/670407/Experimental_Setup_to_Compare_Measurements_and_Numerical_Simulations_in_Magnetic_Resonance_Imaging_RF_Dosimetry.docx","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075184181","display_name":"Umberto Zanovello","orcid":"https://orcid.org/0000-0001-6415-9967"},"institutions":[{"id":"https://openalex.org/I177477856","display_name":"Politecnico di Torino","ror":"https://ror.org/00bgk9508","country_code":"IT","type":"education","lineage":["https://openalex.org/I177477856"]},{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Umberto Zanovello","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Turin, Italy","Politecnico di Torino, Turin, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Turin, Italy","institution_ids":["https://openalex.org/I4210136559"]},{"raw_affiliation_string":"Politecnico di Torino, Turin, Italy","institution_ids":["https://openalex.org/I177477856"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003809358","display_name":"M. Borsero","orcid":null},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Michele Borsero","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Turin, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Turin, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5045083630","display_name":"Domenico Giordano","orcid":"https://orcid.org/0000-0002-2616-9459"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Domenico Giordano","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Turin, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Turin, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5018167803","display_name":"Luca Zilberti","orcid":"https://orcid.org/0000-0002-2382-4710"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Luca Zilberti","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Turin, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Turin, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074145816","display_name":"Francesca Maggiorelli","orcid":"https://orcid.org/0000-0002-0660-8047"},"institutions":[{"id":"https://openalex.org/I102064193","display_name":"University of Siena","ror":"https://ror.org/01tevnk56","country_code":"IT","type":"education","lineage":["https://openalex.org/I102064193"]},{"id":"https://openalex.org/I4210160382","display_name":"Istituto Nazionale di Fisica Nucleare, Sezione di Pisa","ror":"https://ror.org/05symbg58","country_code":"IT","type":"facility","lineage":["https://openalex.org/I160013858","https://openalex.org/I4210160382"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Francesca Maggiorelli","raw_affiliation_strings":["Dipartimento di Scienze Fisiche, Universit\u00e0 di Siena, Siena, Italy","Sezione di Pisa, Istituto Nazionale di Fisica Nucleare, Pisa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Scienze Fisiche, Universit\u00e0 di Siena, Siena, Italy","institution_ids":["https://openalex.org/I102064193"]},{"raw_affiliation_string":"Sezione di Pisa, Istituto Nazionale di Fisica Nucleare, Pisa, Italy","institution_ids":["https://openalex.org/I4210160382"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5029583692","display_name":"Gianluigi Tiberi","orcid":"https://orcid.org/0000-0001-8787-1295"},"institutions":[{"id":"https://openalex.org/I4210126460","display_name":"Fondazione Stella Maris","ror":"https://ror.org/02w8ez808","country_code":"IT","type":"healthcare","lineage":["https://openalex.org/I4210126460","https://openalex.org/I4210153126"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Gianluigi Tiberi","raw_affiliation_strings":["Imago7 Foundation, Pisa, Italy","Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, IRCCS Stella Maris Foundation, Pisa, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Imago7 Foundation, Pisa, Italy","institution_ids":[]},{"raw_affiliation_string":"Laboratory of Medical Physics and Biotechnologies for Magnetic Resonance, IRCCS Stella Maris Foundation, Pisa, Italy","institution_ids":["https://openalex.org/I4210126460"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":6,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.6581,"has_fulltext":false,"cited_by_count":11,"citation_normalized_percentile":{"value":0.69523624,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"66","issue":"6","first_page":"1208","last_page":"1216"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10378","display_name":"Advanced MRI Techniques and Applications","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2741","display_name":"Radiology, Nuclear Medicine and Imaging"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11993","display_name":"Atomic and Subatomic Physics Research","score":0.9983000159263611,"subfield":{"id":"https://openalex.org/subfields/3107","display_name":"Atomic and Molecular Physics, and Optics"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10958","display_name":"Ultrasound and Hyperthermia Applications","score":0.9973999857902527,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dosimetry","display_name":"Dosimetry","score":0.6719935536384583},{"id":"https://openalex.org/keywords/magnetic-resonance-imaging","display_name":"Magnetic resonance imaging","score":0.5201112031936646},{"id":"https://openalex.org/keywords/resonance","display_name":"Resonance (particle physics)","score":0.46309781074523926},{"id":"https://openalex.org/keywords/radio-frequency","display_name":"Radio frequency","score":0.4496290981769562},{"id":"https://openalex.org/keywords/computer-simulation","display_name":"Computer simulation","score":0.44802579283714294},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.41059818863868713},{"id":"https://openalex.org/keywords/computational-physics","display_name":"Computational physics","score":0.40197229385375977},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.3384043872356415},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.33151230216026306},{"id":"https://openalex.org/keywords/nuclear-magnetic-resonance","display_name":"Nuclear magnetic resonance","score":0.32465803623199463},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.17751702666282654},{"id":"https://openalex.org/keywords/nuclear-medicine","display_name":"Nuclear medicine","score":0.0839499831199646},{"id":"https://openalex.org/keywords/telecommunications","display_name":"Telecommunications","score":0.06712296605110168}],"concepts":[{"id":"https://openalex.org/C75088862","wikidata":"https://www.wikidata.org/wiki/Q2291081","display_name":"Dosimetry","level":2,"score":0.6719935536384583},{"id":"https://openalex.org/C143409427","wikidata":"https://www.wikidata.org/wiki/Q161238","display_name":"Magnetic resonance imaging","level":2,"score":0.5201112031936646},{"id":"https://openalex.org/C139210041","wikidata":"https://www.wikidata.org/wiki/Q2145840","display_name":"Resonance (particle physics)","level":2,"score":0.46309781074523926},{"id":"https://openalex.org/C74064498","wikidata":"https://www.wikidata.org/wiki/Q3396184","display_name":"Radio frequency","level":2,"score":0.4496290981769562},{"id":"https://openalex.org/C500300565","wikidata":"https://www.wikidata.org/wiki/Q925667","display_name":"Computer simulation","level":2,"score":0.44802579283714294},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.41059818863868713},{"id":"https://openalex.org/C30475298","wikidata":"https://www.wikidata.org/wiki/Q909554","display_name":"Computational physics","level":1,"score":0.40197229385375977},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3384043872356415},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.33151230216026306},{"id":"https://openalex.org/C46141821","wikidata":"https://www.wikidata.org/wiki/Q209402","display_name":"Nuclear magnetic resonance","level":1,"score":0.32465803623199463},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.17751702666282654},{"id":"https://openalex.org/C2989005","wikidata":"https://www.wikidata.org/wiki/Q214963","display_name":"Nuclear medicine","level":1,"score":0.0839499831199646},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.06712296605110168},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C109214941","wikidata":"https://www.wikidata.org/wiki/Q18334","display_name":"Particle physics","level":1,"score":0.0},{"id":"https://openalex.org/C126838900","wikidata":"https://www.wikidata.org/wiki/Q77604","display_name":"Radiology","level":1,"score":0.0}],"mesh":[],"locations_count":5,"locations":[{"id":"doi:10.1109/tim.2017.2687138","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2017.2687138","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:openresearch.lsbu.ac.uk:917wx","is_oa":true,"landing_page_url":"https://openresearch.lsbu.ac.uk/download/565ed363ed56eee09c107ceb809bfeb7bcadff4caac01521922ae86e623cb0f7/670407/Experimental_Setup_to_Compare_Measurements_and_Numerical_Simulations_in_Magnetic_Resonance_Imaging_RF_Dosimetry.docx","pdf_url":null,"source":{"id":"https://openalex.org/S4306401135","display_name":"Research Open (London South Bank University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28257850","host_organization_name":"London South Bank University","host_organization_lineage":["https://openalex.org/I28257850"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"journal-article"},{"id":"pmh:oai:iris.inrim.it:11696/55145","is_oa":true,"landing_page_url":"http://hdl.handle.net/11696/55145","pdf_url":null,"source":{"id":"https://openalex.org/S4306400708","display_name":"CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I27837315","host_organization_name":"University of Michigan","host_organization_lineage":["https://openalex.org/I27837315"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"},{"id":"pmh:oai:porto.polito.it:2645774","is_oa":false,"landing_page_url":"http://porto.polito.it/2645774/","pdf_url":null,"source":{"id":"https://openalex.org/S4306402038","display_name":"PORTO Publications Open Repository TOrino (Politecnico di Torino)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I177477856","host_organization_name":"Politecnico di Torino","host_organization_lineage":["https://openalex.org/I177477856"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"info:eu-repo/semantics/conferenceObject"},{"id":"pmh:oai:porto.polito.it:2669207","is_oa":false,"landing_page_url":"http://porto.polito.it/2669207/","pdf_url":null,"source":{"id":"https://openalex.org/S4306402038","display_name":"PORTO Publications Open Repository TOrino (Politecnico di Torino)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I177477856","host_organization_name":"Politecnico di Torino","host_organization_lineage":["https://openalex.org/I177477856"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ISSN:0018-9456","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:openresearch.lsbu.ac.uk:917wx","is_oa":true,"landing_page_url":"https://openresearch.lsbu.ac.uk/download/565ed363ed56eee09c107ceb809bfeb7bcadff4caac01521922ae86e623cb0f7/670407/Experimental_Setup_to_Compare_Measurements_and_Numerical_Simulations_in_Magnetic_Resonance_Imaging_RF_Dosimetry.docx","pdf_url":null,"source":{"id":"https://openalex.org/S4306401135","display_name":"Research Open (London South Bank University)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I28257850","host_organization_name":"London South Bank University","host_organization_lineage":["https://openalex.org/I28257850"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"acceptedVersion","is_accepted":true,"is_published":false,"raw_source_name":"","raw_type":"journal-article"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":7,"referenced_works":["https://openalex.org/W1494271441","https://openalex.org/W1984892845","https://openalex.org/W2022981781","https://openalex.org/W2115842626","https://openalex.org/W2145775854","https://openalex.org/W2331487595","https://openalex.org/W4234364467"],"related_works":["https://openalex.org/W2115968180","https://openalex.org/W2065864741","https://openalex.org/W4205482557","https://openalex.org/W2064873898","https://openalex.org/W4285153207","https://openalex.org/W2068340264","https://openalex.org/W2412325395","https://openalex.org/W1972877072","https://openalex.org/W2547184060","https://openalex.org/W1990885697"],"abstract_inverted_index":{"Many":[0],"of":[1,16,28,34,52,68,79,93],"the":[2,6,22,29,35,48,56,69,80,84,89],"parameters":[3,81],"associated":[4,82],"with":[5,83],"magnetic":[7],"resonance":[8],"imaging":[9],"(MRI)":[10],"coils":[11,101],"are":[12],"estimated":[13],"by":[14],"means":[15],"numerical":[17,24,70],"simulations.":[18],"Taking":[19],"into":[20],"account":[21],"unavoidable":[23],"approximations":[25],"and":[26,55,91],"imperfections":[27],"models,":[30],"an":[31],"experimental":[32,62,96],"validation":[33],"theoretical":[36],"results":[37,71],"becomes":[38],"essential.":[39],"This":[40],"paper":[41],"describes":[42],"two":[43],"measuring":[44],"setups":[45],"which":[46],"allow":[47],"comparison":[49],"between":[50],"measurements":[51],"electromagnetic":[53],"fields":[54],"same":[57],"quantities":[58],"computed":[59],"numerically.":[60],"The":[61],"activity":[63],"highlighted":[64],"some":[65],"critical":[66],"aspects":[67],"that":[72],"could":[73],"bring":[74],"to":[75],"a":[76,94],"wrong":[77],"estimation":[78],"MRI":[85,100],"coils.":[86],"Results":[87],"show":[88],"importance":[90],"feasibility":[92],"dosimetry":[95],"setup":[97],"suitable":[98],"for":[99],"characterization.":[102]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2022,"cited_by_count":2},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":1}],"updated_date":"2026-06-11T09:08:48.828518","created_date":"2025-10-10T00:00:00"}