{"id":"https://openalex.org/W2569257911","doi":"https://doi.org/10.1109/tim.2016.2644878","title":"Parameters and Methods for ADCs Testing Compliant With the Guide to the Expression of Uncertainty in Measurements","display_name":"Parameters and Methods for ADCs Testing Compliant With the Guide to the Expression of Uncertainty in Measurements","publication_year":2017,"publication_date":"2017-01-10","ids":{"openalex":"https://openalex.org/W2569257911","doi":"https://doi.org/10.1109/tim.2016.2644878","mag":"2569257911"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2016.2644878","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2016.2644878","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5089618436","display_name":"A. Baccigalupi","orcid":"https://orcid.org/0000-0002-4975-7018"},"institutions":[{"id":"https://openalex.org/I71267560","display_name":"University of Naples Federico II","ror":"https://ror.org/05290cv24","country_code":"IT","type":"education","lineage":["https://openalex.org/I71267560"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Aldo Baccigalupi","raw_affiliation_strings":["Universit\u00e0 degli Studi di Napoli Federico II, Naples, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universit\u00e0 degli Studi di Napoli Federico II, Naples, Italy","institution_ids":["https://openalex.org/I71267560"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5006659544","display_name":"Mauro D\u2019Arco","orcid":"https://orcid.org/0000-0003-1641-8359"},"institutions":[{"id":"https://openalex.org/I71267560","display_name":"University of Naples Federico II","ror":"https://ror.org/05290cv24","country_code":"IT","type":"education","lineage":["https://openalex.org/I71267560"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Mauro D'Arco","raw_affiliation_strings":["Universita degli Studi di Napoli Federico II, Napoli, Campania, IT"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universita degli Studi di Napoli Federico II, Napoli, Campania, IT","institution_ids":["https://openalex.org/I71267560"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5013549141","display_name":"Annalisa Liccardo","orcid":"https://orcid.org/0000-0003-1270-4948"},"institutions":[{"id":"https://openalex.org/I71267560","display_name":"University of Naples Federico II","ror":"https://ror.org/05290cv24","country_code":"IT","type":"education","lineage":["https://openalex.org/I71267560"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Annalisa Liccardo","raw_affiliation_strings":["Universit\u00e0 degli Studi di Napoli Federico II, Naples, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universit\u00e0 degli Studi di Napoli Federico II, Naples, Italy","institution_ids":["https://openalex.org/I71267560"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I71267560"],"apc_list":null,"apc_paid":null,"fwci":2.3139,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.89542645,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"66","issue":"3","first_page":"424","last_page":"431"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9984999895095825,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.6770122647285461},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5577613115310669},{"id":"https://openalex.org/keywords/expression","display_name":"Expression (computer science)","score":0.5572364330291748},{"id":"https://openalex.org/keywords/reliability-engineering","display_name":"Reliability engineering","score":0.5329222679138184},{"id":"https://openalex.org/keywords/conformance-testing","display_name":"Conformance testing","score":0.49570000171661377},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"Risk analysis (engineering)","score":0.45348119735717773},{"id":"https://openalex.org/keywords/systems-engineering","display_name":"Systems engineering","score":0.35697996616363525},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.320360392332077},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.30655014514923096},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.12166351079940796},{"id":"https://openalex.org/keywords/standardization","display_name":"Standardization","score":0.11182525753974915},{"id":"https://openalex.org/keywords/statistics","display_name":"Statistics","score":0.08354097604751587}],"concepts":[{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.6770122647285461},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5577613115310669},{"id":"https://openalex.org/C90559484","wikidata":"https://www.wikidata.org/wiki/Q778379","display_name":"Expression (computer science)","level":2,"score":0.5572364330291748},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5329222679138184},{"id":"https://openalex.org/C76844732","wikidata":"https://www.wikidata.org/wiki/Q4072285","display_name":"Conformance testing","level":3,"score":0.49570000171661377},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.45348119735717773},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.35697996616363525},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.320360392332077},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30655014514923096},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.12166351079940796},{"id":"https://openalex.org/C188087704","wikidata":"https://www.wikidata.org/wiki/Q369577","display_name":"Standardization","level":2,"score":0.11182525753974915},{"id":"https://openalex.org/C105795698","wikidata":"https://www.wikidata.org/wiki/Q12483","display_name":"Statistics","level":1,"score":0.08354097604751587},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C199360897","wikidata":"https://www.wikidata.org/wiki/Q9143","display_name":"Programming language","level":1,"score":0.0},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2016.2644878","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2016.2644878","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.4300000071525574,"id":"https://metadata.un.org/sdg/17","display_name":"Partnerships for the goals"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":39,"referenced_works":["https://openalex.org/W1499206700","https://openalex.org/W1500355126","https://openalex.org/W1557306901","https://openalex.org/W1968904754","https://openalex.org/W1969286095","https://openalex.org/W1990211292","https://openalex.org/W2006095765","https://openalex.org/W2038932764","https://openalex.org/W2054301506","https://openalex.org/W2061054290","https://openalex.org/W2062679738","https://openalex.org/W2063724383","https://openalex.org/W2087766854","https://openalex.org/W2095410544","https://openalex.org/W2099738102","https://openalex.org/W2100382391","https://openalex.org/W2114064015","https://openalex.org/W2114268672","https://openalex.org/W2117864065","https://openalex.org/W2119387768","https://openalex.org/W2120402734","https://openalex.org/W2129523661","https://openalex.org/W2133600276","https://openalex.org/W2137740093","https://openalex.org/W2140923832","https://openalex.org/W2146878358","https://openalex.org/W2153307716","https://openalex.org/W2170551752","https://openalex.org/W2171776530","https://openalex.org/W2172205044","https://openalex.org/W2295861972","https://openalex.org/W2315214008","https://openalex.org/W2594776646","https://openalex.org/W2982768424","https://openalex.org/W2985200048","https://openalex.org/W2985592582","https://openalex.org/W2985808567","https://openalex.org/W2985998267","https://openalex.org/W2989306645"],"related_works":["https://openalex.org/W2000983334","https://openalex.org/W2352994864","https://openalex.org/W2364507636","https://openalex.org/W2375657886","https://openalex.org/W2484235349","https://openalex.org/W1846991674","https://openalex.org/W2387496793","https://openalex.org/W2392243736","https://openalex.org/W2073464218","https://openalex.org/W1845219951"],"abstract_inverted_index":{"Virtual":[0],"instruments":[1,18],"let":[2],"the":[3,26,29,32,42,48,55,67,74,79,83,87,95,108,111],"user":[4],"define":[5],"custom":[6],"measurement":[7,33],"approaches":[8],"to":[9,46,110],"cope":[10],"with":[11],"specific":[12],"goals.":[13],"The":[14],"use":[15],"of":[16,28,31,69,73,113],"virtual":[17],"also":[19],"raises":[20],"an":[21],"important":[22],"issue,":[23,38],"which":[24],"concerns":[25],"evaluation":[27],"uncertainty":[30,114],"results.":[34],"To":[35],"face":[36],"this":[37],"a":[39],"change":[40,64],"in":[41,107,115],"praxis":[43],"currently":[44],"adopted":[45,77],"interpret":[47],"analog-to-digital":[49],"converter":[50],"(ADC)":[51],"datasheets":[52],"released":[53],"by":[54,78,82,86],"manufacturers":[56],"for":[57,101],"documenting":[58],"their":[59],"products":[60],"seems":[61],"necessary.":[62],"This":[63],"should":[65,93],"be":[66],"consequence":[68],"modifications":[70],"and/or":[71,91],"integrations":[72,92],"standard":[75],"documents":[76],"same":[80],"manufactures,":[81],"way":[84],"proposed":[85],"scientific":[88],"community.":[89],"Modifications":[90],"assure":[94],"compliance":[96],"between":[97],"parameters":[98],"and":[99,104],"methods":[100],"ADC":[102],"testing":[103],"recommendations":[105],"contained":[106],"guide":[109],"expression":[112],"measurement.":[116]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":3},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":2}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
