{"id":"https://openalex.org/W2312423949","doi":"https://doi.org/10.1109/tim.2015.2495719","title":"An Easy-to-Interface CDC With an Efficient Automatic Calibration","display_name":"An Easy-to-Interface CDC With an Efficient Automatic Calibration","publication_year":2015,"publication_date":"2015-11-19","ids":{"openalex":"https://openalex.org/W2312423949","doi":"https://doi.org/10.1109/tim.2015.2495719","mag":"2312423949"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2015.2495719","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2495719","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5101725583","display_name":"Sreenath Vijayakumar","orcid":"https://orcid.org/0000-0003-2289-0924"},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"education","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Vijayakumar Sreenath","raw_affiliation_strings":["Department of Electrical Engineering, IIT Chennai, Chennai, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, IIT Chennai, Chennai, India","institution_ids":["https://openalex.org/I24676775"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5086437761","display_name":"Boby George","orcid":"https://orcid.org/0000-0001-9923-6328"},"institutions":[{"id":"https://openalex.org/I24676775","display_name":"Indian Institute of Technology Madras","ror":"https://ror.org/03v0r5n49","country_code":"IN","type":"education","lineage":["https://openalex.org/I24676775"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Boby George","raw_affiliation_strings":["Department of Electrical Engineering, IIT Chennai, Chennai, India"],"raw_orcid":"https://orcid.org/0000-0001-9923-6328","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, IIT Chennai, Chennai, India","institution_ids":["https://openalex.org/I24676775"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I24676775"],"apc_list":null,"apc_paid":null,"fwci":1.2415,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.79485124,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"65","issue":"5","first_page":"960","last_page":"967"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.7123269438743591},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.599362850189209},{"id":"https://openalex.org/keywords/interface","display_name":"Interface (matter)","score":0.5799940824508667},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.18530422449111938},{"id":"https://openalex.org/keywords/operating-system","display_name":"Operating system","score":0.16358163952827454}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.7123269438743591},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.599362850189209},{"id":"https://openalex.org/C113843644","wikidata":"https://www.wikidata.org/wiki/Q901882","display_name":"Interface (matter)","level":4,"score":0.5799940824508667},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.18530422449111938},{"id":"https://openalex.org/C111919701","wikidata":"https://www.wikidata.org/wiki/Q9135","display_name":"Operating system","level":1,"score":0.16358163952827454},{"id":"https://openalex.org/C129307140","wikidata":"https://www.wikidata.org/wiki/Q6795880","display_name":"Maximum bubble pressure method","level":3,"score":0.0},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2015.2495719","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2495719","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":15,"referenced_works":["https://openalex.org/W1485797785","https://openalex.org/W1534156853","https://openalex.org/W1591300912","https://openalex.org/W2011431440","https://openalex.org/W2013606760","https://openalex.org/W2015461548","https://openalex.org/W2024354368","https://openalex.org/W2056184138","https://openalex.org/W2058163584","https://openalex.org/W2089647432","https://openalex.org/W2105990803","https://openalex.org/W2112432920","https://openalex.org/W2115503606","https://openalex.org/W2155484154","https://openalex.org/W2167287281"],"related_works":["https://openalex.org/W2366230866","https://openalex.org/W2357906747","https://openalex.org/W2372895414","https://openalex.org/W2390158879","https://openalex.org/W2348049494","https://openalex.org/W1992987618","https://openalex.org/W2383005052","https://openalex.org/W2015716388","https://openalex.org/W2045811478","https://openalex.org/W2746231933"],"abstract_inverted_index":{"A":[0,228,250],"new":[1,60,135],"capacitance-to-digital":[2],"converter":[3],"(CDC)":[4],"that":[5,190,265],"gives":[6],"a":[7,36,50,59,79,93,96,134,140,147,273],"digital":[8],"output":[9,34,101,153,267],"proportional":[10],"to":[11,65,89,105,115,207,213,289],"the":[12,30,39,47,56,69,75,84,100,109,119,124,156,162,177,180,191,200,203,210,215,218,221,226,232,240,253,266,269,276,293],"measurand":[13],"kx,":[14],"independent":[15,154],"of":[16,38,46,74,99,118,126,155,161,179,220,231,234,237,252,268,275,292],"its":[17],"nominal":[18,40],"capacitance,":[19],"is":[20,35,53,63,77,103,128,168,187,271],"reported":[21],"in":[22,29,55,86,92,146,202,225,239,247],"this":[23,208,248],"paper.":[24,249],"Various":[25],"CDCs":[26],"are":[27],"available":[28],"market,":[31],"but":[32],"their":[33],"function":[37,274],"value":[41,81],"C":[42,70,110,157,277],"<sub":[43,71,111,158,278,282],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[44,72,112,159,279,283],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">0</sub>":[45,73,113,160,280,284],"sensor.":[48],"Thus,":[49,91],"manual":[51],"correction":[52],"required":[54],"output,":[57],"whenever":[58],"capacitive":[61],"sensor":[62,163],"interfaced":[64],"such":[66,189],"CDCs.":[67],"Moreover,":[68],"sensors":[76,294],"usually":[78],"large":[80,97],"compared":[82],"with":[83],"change":[85,201],"capacitance":[87],"due":[88],"kx.":[90,204],"typical":[94],"CDC,":[95],"percentage":[98],"counts/bits":[102],"used":[104,197],"measure":[106],"and":[107,150,175,245,259],"represent":[108],"leading":[114],"an":[116,152,171],"underutilization":[117],"hardware":[120],"as":[121,123],"far":[122],"measurement":[125],"kx":[127],"concerned.":[129],"The":[130,165,184,261],"proposed":[131,166,254],"CDC":[132,167,185,241,255,270],"uses":[133],"automatic":[136],"calibration":[137],"(AC),":[138],"employing":[139],"switched-capacitor":[141],"(SC)":[142],"circuit-based":[143],"voltage":[144],"source":[145],"feedback":[148],"topology,":[149],"provides":[151],"employed.":[164],"based":[169],"on":[170,217],"SC":[172],"dual-slope":[173,181],"technique":[174],"possesses":[176],"advantages":[178],"conversion":[182],"method.":[183],"circuit":[186],"designed":[188],"entire":[192],"full":[193],"scale":[194],"can":[195],"be":[196],"for":[198],"representing":[199],"In":[205],"addition":[206],"advantage,":[209],"AC":[211],"helps":[212],"remove":[214],"dependence":[216],"accuracy":[219],"reference":[222],"capacitor":[223],"employed":[224],"CDC.":[227],"detailed":[229],"analysis":[230],"effect":[233],"various":[235],"sources":[236],"errors":[238],"has":[242,256],"been":[243,257],"conducted":[244],"presented":[246],"prototype":[251],"developed":[258],"tested.":[260],"results":[262],"obtained":[263],"show":[264],"not":[272],"(C":[281],"varied":[285],"from":[286],"60":[287],"pF":[288],"1.46":[290],"nF)":[291],"interfaced.":[295]},"counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":4},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
