{"id":"https://openalex.org/W2203084484","doi":"https://doi.org/10.1109/tim.2015.2479107","title":"Improvement of LISN Measurement Accuracy Based on Calculable Adapters","display_name":"Improvement of LISN Measurement Accuracy Based on Calculable Adapters","publication_year":2015,"publication_date":"2015-10-13","ids":{"openalex":"https://openalex.org/W2203084484","doi":"https://doi.org/10.1109/tim.2015.2479107","mag":"2203084484"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2015.2479107","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2479107","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5004600779","display_name":"Fran\u00e7ois Ziad\u00e9","orcid":"https://orcid.org/0000-0002-0996-9817"},"institutions":[{"id":"https://openalex.org/I4210107682","display_name":"Laboratoire National de M\u00e9trologie et d'Essais","ror":"https://ror.org/01ph39d13","country_code":"FR","type":"other","lineage":["https://openalex.org/I4210107682"]}],"countries":["FR"],"is_corresponding":true,"raw_author_name":"Francois Ziade","raw_affiliation_strings":["Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France"],"affiliations":[{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]},{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040011671","display_name":"Miha Kokalj","orcid":null},"institutions":[{"id":"https://openalex.org/I4210107811","display_name":"Slovenian Institute of Quality and Metrology","ror":"https://ror.org/02gmdvw97","country_code":"SI","type":"facility","lineage":["https://openalex.org/I4210107811"]}],"countries":["SI"],"is_corresponding":false,"raw_author_name":"Miha Kokalj","raw_affiliation_strings":["Slovenian Institute of Quality and Metrology, Ljubljana, Slovenia"],"affiliations":[{"raw_affiliation_string":"Slovenian Institute of Quality and Metrology, Ljubljana, Slovenia","institution_ids":["https://openalex.org/I4210107811"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003587364","display_name":"Mohamed Ouameur","orcid":"https://orcid.org/0000-0002-4775-362X"},"institutions":[{"id":"https://openalex.org/I4210107682","display_name":"Laboratoire National de M\u00e9trologie et d'Essais","ror":"https://ror.org/01ph39d13","country_code":"FR","type":"other","lineage":["https://openalex.org/I4210107682"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Mohamed Ouameur","raw_affiliation_strings":["Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France"],"affiliations":[{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]},{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5022657710","display_name":"Borut Pinter","orcid":null},"institutions":[{"id":"https://openalex.org/I4210107811","display_name":"Slovenian Institute of Quality and Metrology","ror":"https://ror.org/02gmdvw97","country_code":"SI","type":"facility","lineage":["https://openalex.org/I4210107811"]}],"countries":["SI"],"is_corresponding":false,"raw_author_name":"Borut Pinter","raw_affiliation_strings":["Slovenian Institute of Quality and Metrology, Ljubljana, Slovenia"],"affiliations":[{"raw_affiliation_string":"Slovenian Institute of Quality and Metrology, Ljubljana, Slovenia","institution_ids":["https://openalex.org/I4210107811"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044912922","display_name":"Denis B\u00e9li\u00e8res","orcid":null},"institutions":[{"id":"https://openalex.org/I4210107682","display_name":"Laboratoire National de M\u00e9trologie et d'Essais","ror":"https://ror.org/01ph39d13","country_code":"FR","type":"other","lineage":["https://openalex.org/I4210107682"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Denis Belieres","raw_affiliation_strings":["Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France"],"affiliations":[{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]},{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046391224","display_name":"A. Pol\u00e9taeff","orcid":null},"institutions":[{"id":"https://openalex.org/I4210107682","display_name":"Laboratoire National de M\u00e9trologie et d'Essais","ror":"https://ror.org/01ph39d13","country_code":"FR","type":"other","lineage":["https://openalex.org/I4210107682"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Andre Poletaeff","raw_affiliation_strings":["Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France"],"affiliations":[{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]},{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5086867595","display_name":"Djamel Allal","orcid":"https://orcid.org/0000-0001-6907-2414"},"institutions":[{"id":"https://openalex.org/I4210107682","display_name":"Laboratoire National de M\u00e9trologie et d'Essais","ror":"https://ror.org/01ph39d13","country_code":"FR","type":"other","lineage":["https://openalex.org/I4210107682"]}],"countries":["FR"],"is_corresponding":false,"raw_author_name":"Djamel Allal","raw_affiliation_strings":["Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France"],"affiliations":[{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d\u2019Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]},{"raw_affiliation_string":"Laboratoire National de M\u00e9trologie et d'Essais, Trappes, France","institution_ids":["https://openalex.org/I4210107682"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":7,"corresponding_author_ids":["https://openalex.org/A5004600779"],"corresponding_institution_ids":["https://openalex.org/I4210107682"],"apc_list":null,"apc_paid":null,"fwci":1.1837,"has_fulltext":false,"cited_by_count":16,"citation_normalized_percentile":{"value":0.81959246,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":97},"biblio":{"volume":"65","issue":"2","first_page":"365","last_page":"377"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11444","display_name":"Electromagnetic Compatibility and Noise Suppression","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11851","display_name":"Electromagnetic Compatibility and Measurements","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11607","display_name":"Microwave and Dielectric Measurement Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/adapter","display_name":"Adapter (computing)","score":0.8521237373352051},{"id":"https://openalex.org/keywords/electrical-impedance","display_name":"Electrical impedance","score":0.7205211520195007},{"id":"https://openalex.org/keywords/electromagnetic-compatibility","display_name":"Electromagnetic compatibility","score":0.7152338624000549},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.6229078769683838},{"id":"https://openalex.org/keywords/network-analyzer","display_name":"Network analyzer (electrical)","score":0.5948337316513062},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.528897225856781},{"id":"https://openalex.org/keywords/input-impedance","display_name":"Input impedance","score":0.5066347718238831},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.4832206964492798},{"id":"https://openalex.org/keywords/device-under-test","display_name":"Device under test","score":0.45515817403793335},{"id":"https://openalex.org/keywords/focused-impedance-measurement","display_name":"Focused Impedance Measurement","score":0.44790220260620117},{"id":"https://openalex.org/keywords/electromagnetic-interference","display_name":"Electromagnetic interference","score":0.43231403827667236},{"id":"https://openalex.org/keywords/impedance-matching","display_name":"Impedance matching","score":0.4222417175769806},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.4212353527545929},{"id":"https://openalex.org/keywords/scattering-parameters","display_name":"Scattering parameters","score":0.3809368312358856},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.372225284576416},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.32549965381622314},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.14840227365493774}],"concepts":[{"id":"https://openalex.org/C177284502","wikidata":"https://www.wikidata.org/wiki/Q1005390","display_name":"Adapter (computing)","level":2,"score":0.8521237373352051},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.7205211520195007},{"id":"https://openalex.org/C125470083","wikidata":"https://www.wikidata.org/wiki/Q747288","display_name":"Electromagnetic compatibility","level":2,"score":0.7152338624000549},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.6229078769683838},{"id":"https://openalex.org/C99101257","wikidata":"https://www.wikidata.org/wiki/Q1529374","display_name":"Network analyzer (electrical)","level":2,"score":0.5948337316513062},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.528897225856781},{"id":"https://openalex.org/C26262908","wikidata":"https://www.wikidata.org/wiki/Q1307489","display_name":"Input impedance","level":3,"score":0.5066347718238831},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.4832206964492798},{"id":"https://openalex.org/C76249512","wikidata":"https://www.wikidata.org/wiki/Q1206780","display_name":"Device under test","level":3,"score":0.45515817403793335},{"id":"https://openalex.org/C172066009","wikidata":"https://www.wikidata.org/wiki/Q5463955","display_name":"Focused Impedance Measurement","level":3,"score":0.44790220260620117},{"id":"https://openalex.org/C184892835","wikidata":"https://www.wikidata.org/wiki/Q1474513","display_name":"Electromagnetic interference","level":2,"score":0.43231403827667236},{"id":"https://openalex.org/C612350","wikidata":"https://www.wikidata.org/wiki/Q1761108","display_name":"Impedance matching","level":3,"score":0.4222417175769806},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.4212353527545929},{"id":"https://openalex.org/C195266298","wikidata":"https://www.wikidata.org/wiki/Q2165620","display_name":"Scattering parameters","level":2,"score":0.3809368312358856},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.372225284576416},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.32549965381622314},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.14840227365493774},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2015.2479107","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2479107","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7900000214576721,"display_name":"Affordable and clean energy"}],"awards":[{"id":"https://openalex.org/G1958968377","display_name":null,"funder_award_id":"912/2009/EC","funder_id":"https://openalex.org/F4320320300","funder_display_name":"European Commission"}],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W1486069742","https://openalex.org/W1489328691","https://openalex.org/W1523280996","https://openalex.org/W1703438669","https://openalex.org/W1921422306","https://openalex.org/W1943726889","https://openalex.org/W1963648875","https://openalex.org/W2103620692","https://openalex.org/W2127316943","https://openalex.org/W2163776274","https://openalex.org/W2331295330","https://openalex.org/W2543828402","https://openalex.org/W2798875205","https://openalex.org/W3003384026","https://openalex.org/W4253687614","https://openalex.org/W6628848853","https://openalex.org/W6629380924","https://openalex.org/W6729280088","https://openalex.org/W7018949827"],"related_works":["https://openalex.org/W2158451083","https://openalex.org/W2535680364","https://openalex.org/W3005633134","https://openalex.org/W2168382331","https://openalex.org/W2044175881","https://openalex.org/W2101969039","https://openalex.org/W2003525033","https://openalex.org/W2142514144","https://openalex.org/W2152831568","https://openalex.org/W2474090760"],"abstract_inverted_index":{"The":[0,23],"line":[1],"impedance":[2,25,97,152],"stabilization":[3],"network":[4,49],"(LISN)":[5],"is":[6,26,43,65],"mostly":[7],"used":[8,83],"in":[9,33],"electromagnetic":[10],"compatibility":[11],"(EMC)":[12],"for":[13,107,130],"conducted":[14],"and":[15,20,95,104,124,142,146],"radiated":[16],"radio":[17],"frequency":[18],"emission":[19],"susceptibility":[21],"tests.":[22],"input":[24,39,144],"one":[27],"of":[28,57,66,80,110,119,122],"the":[29,38,47,52,58,78,81,93,101,108,117,135,137,147,151],"most":[30],"important":[31],"parameters":[32],"LISN":[34],"calibration.":[35],"To":[36],"measure":[37],"impedance,":[40,145],"an":[41],"adapter":[42,82],"required":[44],"to":[45,51,69,150],"connect":[46],"vector":[48],"analyzer":[50],"equipment":[53],"under":[54],"test":[55,62],"port":[56],"LISN.":[59],"For":[60],"EMC":[61],"laboratories,":[63],"it":[64],"best":[67],"interest":[68],"perform":[70],"this":[71],"calibration":[72],"with":[73],"high":[74],"accuracy.":[75],"Until":[76],"now,":[77],"impact":[79,133],"has":[84],"not":[85],"been":[86],"clearly":[87],"demonstrated":[88],"theoretically.":[89],"This":[90],"paper":[91],"explains":[92],"magnitude":[94,141],"phase":[96,143],"errors":[98],"caused":[99],"by":[100],"adapter.":[102],"Theoretical":[103],"practical":[105],"methods":[106],"elimination":[109],"generated":[111],"error":[112,139],"are":[113],"given.":[114],"We":[115],"present":[116],"design":[118],"two":[120],"sets":[121],"adapters":[123],"their":[125,132],"associated":[126],"modeling,":[127],"a":[128],"method":[129],"removing":[131],"from":[134],"measurement,":[136],"theoretical":[138],"on":[140],"uncertainties":[148],"related":[149],"measurement.":[153]},"counts_by_year":[{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":2},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
