{"id":"https://openalex.org/W1620478295","doi":"https://doi.org/10.1109/tim.2015.2434096","title":"Accurate DC Current Ratio Measurements for Primary Currents up to 600 A","display_name":"Accurate DC Current Ratio Measurements for Primary Currents up to 600 A","publication_year":2015,"publication_date":"2015-06-02","ids":{"openalex":"https://openalex.org/W1620478295","doi":"https://doi.org/10.1109/tim.2015.2434096","mag":"1620478295"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2015.2434096","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2434096","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5073844637","display_name":"Gert Rietveld","orcid":"https://orcid.org/0000-0002-5239-4019"},"institutions":[{"id":"https://openalex.org/I4210164637","display_name":"VSL Dutch Metrology Institute","ror":"https://ror.org/05ap1vt50","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210164637"]}],"countries":["NL"],"is_corresponding":true,"raw_author_name":"Gert Rietveld","raw_affiliation_strings":["Van Swinden Laboratorium, Delft, The Netherlands",", Van Swinden Laboratorium, Delft, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Van Swinden Laboratorium, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]},{"raw_affiliation_string":", Van Swinden Laboratorium, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023045918","display_name":"Jan H. N. van der Beek","orcid":null},"institutions":[{"id":"https://openalex.org/I4210164637","display_name":"VSL Dutch Metrology Institute","ror":"https://ror.org/05ap1vt50","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210164637"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Jan H. N. van der Beek","raw_affiliation_strings":["Van Swinden Laboratorium, Delft, The Netherlands",", Van Swinden Laboratorium, Delft, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Van Swinden Laboratorium, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]},{"raw_affiliation_string":", Van Swinden Laboratorium, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079714418","display_name":"Ernest Houtzager","orcid":"https://orcid.org/0000-0001-9430-618X"},"institutions":[{"id":"https://openalex.org/I4210164637","display_name":"VSL Dutch Metrology Institute","ror":"https://ror.org/05ap1vt50","country_code":"NL","type":"facility","lineage":["https://openalex.org/I4210164637"]}],"countries":["NL"],"is_corresponding":false,"raw_author_name":"Ernest Houtzager","raw_affiliation_strings":["Van Swinden Laboratorium, Delft, The Netherlands",", Van Swinden Laboratorium, Delft, The Netherlands"],"affiliations":[{"raw_affiliation_string":"Van Swinden Laboratorium, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]},{"raw_affiliation_string":", Van Swinden Laboratorium, Delft, The Netherlands","institution_ids":["https://openalex.org/I4210164637"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5073844637"],"corresponding_institution_ids":["https://openalex.org/I4210164637"],"apc_list":null,"apc_paid":null,"fwci":1.5783,"has_fulltext":false,"cited_by_count":25,"citation_normalized_percentile":{"value":0.84626364,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"64","issue":"11","first_page":"3055","last_page":"3061"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.9988999962806702,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.7205590009689331},{"id":"https://openalex.org/keywords/conductor","display_name":"Conductor","score":0.7088358998298645},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.697060227394104},{"id":"https://openalex.org/keywords/comparator","display_name":"Comparator","score":0.6884762048721313},{"id":"https://openalex.org/keywords/direct-current","display_name":"Direct current","score":0.5569291114807129},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5498115420341492},{"id":"https://openalex.org/keywords/electrical-conductor","display_name":"Electrical conductor","score":0.5495884418487549},{"id":"https://openalex.org/keywords/primary","display_name":"Primary (astronomy)","score":0.46894168853759766},{"id":"https://openalex.org/keywords/position","display_name":"Position (finance)","score":0.465364933013916},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.46206340193748474},{"id":"https://openalex.org/keywords/sensitivity","display_name":"Sensitivity (control systems)","score":0.4527488052845001},{"id":"https://openalex.org/keywords/flux","display_name":"Flux (metallurgy)","score":0.43398240208625793},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.41479235887527466},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3445192575454712},{"id":"https://openalex.org/keywords/analytical-chemistry","display_name":"Analytical Chemistry (journal)","score":0.34067749977111816},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.3105120360851288},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2887296676635742},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.26153069734573364},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.14035382866859436}],"concepts":[{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.7205590009689331},{"id":"https://openalex.org/C34800285","wikidata":"https://www.wikidata.org/wiki/Q5159395","display_name":"Conductor","level":2,"score":0.7088358998298645},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.697060227394104},{"id":"https://openalex.org/C155745195","wikidata":"https://www.wikidata.org/wiki/Q1164179","display_name":"Comparator","level":3,"score":0.6884762048721313},{"id":"https://openalex.org/C2776620479","wikidata":"https://www.wikidata.org/wiki/Q159241","display_name":"Direct current","level":3,"score":0.5569291114807129},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5498115420341492},{"id":"https://openalex.org/C202374169","wikidata":"https://www.wikidata.org/wiki/Q124291","display_name":"Electrical conductor","level":2,"score":0.5495884418487549},{"id":"https://openalex.org/C2777977315","wikidata":"https://www.wikidata.org/wiki/Q7243056","display_name":"Primary (astronomy)","level":2,"score":0.46894168853759766},{"id":"https://openalex.org/C198082294","wikidata":"https://www.wikidata.org/wiki/Q3399648","display_name":"Position (finance)","level":2,"score":0.465364933013916},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.46206340193748474},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.4527488052845001},{"id":"https://openalex.org/C68709404","wikidata":"https://www.wikidata.org/wiki/Q1134475","display_name":"Flux (metallurgy)","level":2,"score":0.43398240208625793},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.41479235887527466},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3445192575454712},{"id":"https://openalex.org/C113196181","wikidata":"https://www.wikidata.org/wiki/Q485223","display_name":"Analytical Chemistry (journal)","level":2,"score":0.34067749977111816},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.3105120360851288},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2887296676635742},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.26153069734573364},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.14035382866859436},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C191897082","wikidata":"https://www.wikidata.org/wiki/Q11467","display_name":"Metallurgy","level":1,"score":0.0},{"id":"https://openalex.org/C1276947","wikidata":"https://www.wikidata.org/wiki/Q333","display_name":"Astronomy","level":1,"score":0.0},{"id":"https://openalex.org/C162324750","wikidata":"https://www.wikidata.org/wiki/Q8134","display_name":"Economics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C10138342","wikidata":"https://www.wikidata.org/wiki/Q43015","display_name":"Finance","level":1,"score":0.0},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2015.2434096","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2015.2434096","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.7599999904632568,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":23,"referenced_works":["https://openalex.org/W1766179879","https://openalex.org/W1965899145","https://openalex.org/W1968744552","https://openalex.org/W1980724492","https://openalex.org/W1994924039","https://openalex.org/W2026503126","https://openalex.org/W2028628740","https://openalex.org/W2037868754","https://openalex.org/W2039144055","https://openalex.org/W2096777464","https://openalex.org/W2119682701","https://openalex.org/W2131308970","https://openalex.org/W2162523726","https://openalex.org/W2164122956","https://openalex.org/W2170695228","https://openalex.org/W2171000465","https://openalex.org/W2324361678","https://openalex.org/W2329032079","https://openalex.org/W2536124821","https://openalex.org/W2908978267","https://openalex.org/W4210809922","https://openalex.org/W6684091021","https://openalex.org/W6744059634"],"related_works":["https://openalex.org/W43901200","https://openalex.org/W2620465761","https://openalex.org/W2074997555","https://openalex.org/W1965494918","https://openalex.org/W2167793574","https://openalex.org/W2048812592","https://openalex.org/W2386068720","https://openalex.org/W2131412785","https://openalex.org/W2353665340","https://openalex.org/W1620478295"],"abstract_inverted_index":{"A":[0,52],"setup":[1],"based":[2],"on":[3],"a":[4,73,76],"direct":[5],"current":[6,24,99],"(dc)":[7],"comparator,":[8],"typically":[9],"employed":[10],"in":[11,61,72,87],"high-current":[12],"low-resistance":[13],"calibrations,":[14],"has":[15],"been":[16],"developed":[17],"for":[18,26],"the":[19,42,48,58,82,85,89,94,97],"accurate":[20],"calibration":[21,74],"of":[22,41,75,84,96],"dc":[23,27],"ratios":[25],"currents":[28,35],"up":[29],"to":[30,93],"600":[31],"A.":[32],"For":[33],"primary":[34,43,98],"above":[36],"100":[37],"A,":[38],"multiple":[39],"turns":[40],"conductor":[44],"are":[45],"made":[46],"through":[47],"device":[49,78],"under":[50],"test.":[51],"full":[53],"uncertainty":[54,68],"analysis":[55],"reveals":[56],"that":[57],"1":[59],"part":[60],"10":[62],"<sup":[63],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[64],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">6</sup>":[65],"total":[66],"expanded":[67],"(k":[69],"=":[70],"2)":[71],"zero-flux":[77],"is":[79],"limited":[80],"by":[81],"behavior":[83],"device,":[86],"particular":[88],"instability":[90],"and":[91],"sensitivity":[92],"position":[95],"conductor.":[100]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":3},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":5},{"year":2019,"cited_by_count":4},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":1},{"year":2016,"cited_by_count":3},{"year":2015,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
