{"id":"https://openalex.org/W2034870529","doi":"https://doi.org/10.1109/tim.2014.2298694","title":"Generation of Reference DC Currents at 1 nA Level With the Capacitance-Charging Method","display_name":"Generation of Reference DC Currents at 1 nA Level With the Capacitance-Charging Method","publication_year":2014,"publication_date":"2014-01-31","ids":{"openalex":"https://openalex.org/W2034870529","doi":"https://doi.org/10.1109/tim.2014.2298694","mag":"2034870529"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2014.2298694","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2014.2298694","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5086308147","display_name":"Luca Callegaro","orcid":"https://orcid.org/0000-0001-5997-9960"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Luca Callegaro","raw_affiliation_strings":["Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112867999","display_name":"Pier Paolo Capra","orcid":"https://orcid.org/0000-0002-7792-969X"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Pier Paolo Capra","raw_affiliation_strings":["Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5062193640","display_name":"Vincenzo D\u2019Elia","orcid":"https://orcid.org/0000-0001-6924-0430"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Vincenzo D'Elia","raw_affiliation_strings":["Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5054682205","display_name":"Flavio Galliana","orcid":"https://orcid.org/0000-0002-5188-6791"},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Flavio Galliana","raw_affiliation_strings":["Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy","institution_ids":["https://openalex.org/I4210136559"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210136559"],"apc_list":null,"apc_paid":null,"fwci":0.6388,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.73583272,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"63","issue":"7","first_page":"1779","last_page":"1782"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998000264167786,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9991000294685364,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/capacitance","display_name":"Capacitance","score":0.8108978271484375},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.7707633376121521},{"id":"https://openalex.org/keywords/voltmeter","display_name":"Voltmeter","score":0.7553443908691406},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.6198841333389282},{"id":"https://openalex.org/keywords/amplifier","display_name":"Amplifier","score":0.5900455713272095},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5032512545585632},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.47410231828689575},{"id":"https://openalex.org/keywords/range","display_name":"Range (aeronautics)","score":0.4512665271759033},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.37360820174217224},{"id":"https://openalex.org/keywords/analytical-chemistry","display_name":"Analytical Chemistry (journal)","score":0.36294761300086975},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.33092206716537476},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.3293672800064087},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.13519591093063354},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.08517888188362122},{"id":"https://openalex.org/keywords/cmos","display_name":"CMOS","score":0.08089280128479004}],"concepts":[{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.8108978271484375},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.7707633376121521},{"id":"https://openalex.org/C165051773","wikidata":"https://www.wikidata.org/wiki/Q179741","display_name":"Voltmeter","level":3,"score":0.7553443908691406},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6198841333389282},{"id":"https://openalex.org/C194257627","wikidata":"https://www.wikidata.org/wiki/Q211554","display_name":"Amplifier","level":3,"score":0.5900455713272095},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5032512545585632},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.47410231828689575},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.4512665271759033},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.37360820174217224},{"id":"https://openalex.org/C113196181","wikidata":"https://www.wikidata.org/wiki/Q485223","display_name":"Analytical Chemistry (journal)","level":2,"score":0.36294761300086975},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.33092206716537476},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3293672800064087},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.13519591093063354},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.08517888188362122},{"id":"https://openalex.org/C46362747","wikidata":"https://www.wikidata.org/wiki/Q173431","display_name":"CMOS","level":2,"score":0.08089280128479004},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.0},{"id":"https://openalex.org/C159985019","wikidata":"https://www.wikidata.org/wiki/Q181790","display_name":"Composite material","level":1,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2014.2298694","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2014.2298694","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.7099999785423279,"display_name":"Affordable and clean energy"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W352914456","https://openalex.org/W1533151001","https://openalex.org/W1597866562","https://openalex.org/W1969865952","https://openalex.org/W1993558533","https://openalex.org/W1997898072","https://openalex.org/W2064076925","https://openalex.org/W2073029777","https://openalex.org/W2101211489","https://openalex.org/W2105522406","https://openalex.org/W2119332195","https://openalex.org/W2122226759","https://openalex.org/W2140453713","https://openalex.org/W2151709370","https://openalex.org/W2159168525","https://openalex.org/W2159196747","https://openalex.org/W2168409019","https://openalex.org/W2314293166","https://openalex.org/W2481735941","https://openalex.org/W2989459258","https://openalex.org/W6721822967"],"related_works":["https://openalex.org/W3122209577","https://openalex.org/W2370694376","https://openalex.org/W1908963913","https://openalex.org/W2902455383","https://openalex.org/W2158542587","https://openalex.org/W3157453784","https://openalex.org/W4255911205","https://openalex.org/W2077630742","https://openalex.org/W4240696014","https://openalex.org/W2058348100"],"abstract_inverted_index":{"The":[0,85,111],"capacitance-charging":[1],"method":[2,23],"is":[3,40,119],"a":[4,25,29,58,67,116],"well-established":[5],"and":[6,28,38,42,74,98,106],"handy":[7],"technique":[8],"for":[9],"the":[10,16,45,49,76,81,91],"generation":[11,77],"of":[12,48,78],"dc":[13],"current":[14,109],"in":[15,70,80,90],"100":[17,104],"pA":[18,105],"range":[19,59],"or":[20],"lower.":[21],"This":[22],"involves":[24],"capacitance":[26],"standard":[27],"sampling":[30],"voltmeter,":[31],"highly":[32],"stable":[33],"devices":[34],"easy":[35],"to":[36,44],"calibrate,":[37],"it":[39],"robust":[41],"insensitive":[43],"voltage":[46],"burden":[47],"instrument":[50,118],"being":[51],"calibrated.":[52],"In":[53],"this":[54],"paper,":[55],"we":[56],"propose":[57],"extender":[60,86],"amplifier,":[61],"which":[62],"can":[63],"be":[64],"employed":[65,89],"as":[66],"plug-in":[68],"component":[69],"existing":[71],"calibration":[72,112],"setups,":[73],"allows":[75],"currents":[79],"1":[82,107,127],"nA":[83,108],"range.":[84],"has":[87],"been":[88],"Istituto":[92],"Nazionale":[93],"di":[94],"Ricerca":[95],"Metrologica":[96],"setup":[97],"validated":[99],"with":[100],"two":[101],"comparisons":[102],"at":[103,126],"levels.":[110],"accuracy":[113],"achieved":[114],"on":[115],"top-class":[117],"5":[120],"\u00d7":[121],"10":[122],"<sup":[123],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[124],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">-5</sup>":[125],"nA.":[128]},"counts_by_year":[{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":2},{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1}],"updated_date":"2026-06-26T08:34:08.712188","created_date":"2025-10-10T00:00:00"}
