{"id":"https://openalex.org/W1968744552","doi":"https://doi.org/10.1109/tim.2013.2265475","title":"DC 5 kA Current Ratio Standards Based on Series\u2013Parallel Self-Calibration DCCs","display_name":"DC 5 kA Current Ratio Standards Based on Series\u2013Parallel Self-Calibration DCCs","publication_year":2013,"publication_date":"2013-06-26","ids":{"openalex":"https://openalex.org/W1968744552","doi":"https://doi.org/10.1109/tim.2013.2265475","mag":"1968744552"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2013.2265475","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2265475","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5001452215","display_name":"Haiming Shao","orcid":"https://orcid.org/0000-0002-3305-4190"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Haiming Shao","raw_affiliation_strings":["Nat. Inst. of Metrol., Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102979842","display_name":"Feipeng Lin","orcid":"https://orcid.org/0000-0002-1108-1622"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Feipeng Lin","raw_affiliation_strings":["Nat. Inst. of Metrol., Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040854060","display_name":"Bo Liang","orcid":"https://orcid.org/0000-0001-6977-7967"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bo Liang","raw_affiliation_strings":["Nat. Inst. of Metrol., Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5037654793","display_name":"Xiaoxin Hua","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xiaoxin Hua","raw_affiliation_strings":["Nat. Inst. of Metrol., Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5046505860","display_name":"Yunfen Lu","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yunfen Lu","raw_affiliation_strings":["Nat. Inst. of Metrol., Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5030194069","display_name":"Kaifeng Qu","orcid":"https://orcid.org/0000-0003-1891-5244"},"institutions":[{"id":"https://openalex.org/I99065089","display_name":"Tsinghua University","ror":"https://ror.org/03cve4549","country_code":"CN","type":"education","lineage":["https://openalex.org/I99065089"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kaifeng Qu","raw_affiliation_strings":["Tsinghua University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tsinghua University, Beijing, China","institution_ids":["https://openalex.org/I99065089"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033526070","display_name":"Yang Pan","orcid":"https://orcid.org/0000-0003-2677-172X"},"institutions":[{"id":"https://openalex.org/I4210105460","display_name":"Shanghai Institute of Measurement and Testing Technology","ror":"https://ror.org/00zcefp03","country_code":"CN","type":"nonprofit","lineage":["https://openalex.org/I4210105460"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yang Pan","raw_affiliation_strings":["Shanghai Inst. of Meas. & Testing Technol., Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Shanghai Inst. of Meas. & Testing Technol., Shanghai, China","institution_ids":["https://openalex.org/I4210105460"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025883155","display_name":"Zhikai Zhang","orcid":"https://orcid.org/0000-0002-1351-3353"},"institutions":[{"id":"https://openalex.org/I4210125933","display_name":"Zhejiang Institute of Metrology","ror":"https://ror.org/02bt6bb31","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210125933"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhikai Zhang","raw_affiliation_strings":["Zhejiang Inst. of Metrol., Hangzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Zhejiang Inst. of Metrol., Hangzhou, China","institution_ids":["https://openalex.org/I4210125933"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044609648","display_name":"Wancai Chen","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wancai Chen","raw_affiliation_strings":["Yunnan Inst. of Meas. & Testing Technol., Kunming, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Yunnan Inst. of Meas. & Testing Technol., Kunming, China","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5110367198","display_name":"Su Hong","orcid":null},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hong Su","raw_affiliation_strings":["Yunnan Inst. of Meas. & Testing Technol., Kunming, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Yunnan Inst. of Meas. & Testing Technol., Kunming, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4697,"has_fulltext":false,"cited_by_count":7,"citation_normalized_percentile":{"value":0.66873752,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":90,"max":97},"biblio":{"volume":"62","issue":"11","first_page":"3093","last_page":"3100"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9968000054359436,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9952999949455261,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.733778178691864},{"id":"https://openalex.org/keywords/series","display_name":"Series (stratigraphy)","score":0.6012115478515625},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.5686576962471008},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.4332137107849121},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.35618945956230164},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.3346622884273529},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.3120908737182617},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.21415406465530396}],"concepts":[{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.733778178691864},{"id":"https://openalex.org/C143724316","wikidata":"https://www.wikidata.org/wiki/Q312468","display_name":"Series (stratigraphy)","level":2,"score":0.6012115478515625},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5686576962471008},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4332137107849121},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.35618945956230164},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3346622884273529},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.3120908737182617},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.21415406465530396},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C86803240","wikidata":"https://www.wikidata.org/wiki/Q420","display_name":"Biology","level":0,"score":0.0},{"id":"https://openalex.org/C151730666","wikidata":"https://www.wikidata.org/wiki/Q7205","display_name":"Paleontology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2013.2265475","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2265475","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.800000011920929}],"awards":[],"funders":[{"id":"https://openalex.org/F4320311508","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2010785712","https://openalex.org/W2014200457","https://openalex.org/W2039878165","https://openalex.org/W2078541498","https://openalex.org/W2098549351","https://openalex.org/W2159740811","https://openalex.org/W2357690699","https://openalex.org/W3164786900","https://openalex.org/W4210809922","https://openalex.org/W6670405525","https://openalex.org/W6683968744"],"related_works":["https://openalex.org/W2748952813","https://openalex.org/W2899084033","https://openalex.org/W1919101720","https://openalex.org/W1982412832","https://openalex.org/W96888382","https://openalex.org/W4244464241","https://openalex.org/W4386126592","https://openalex.org/W2384573129","https://openalex.org/W2351224547","https://openalex.org/W2358945257"],"abstract_inverted_index":{"With":[0],"proper":[1],"design,":[2],"accurate":[3],"current":[4,8,53,58,90,107,150],"ratios":[5,91,108,151],"of":[6,19,22,30,70,109,147,152],"direct":[7],"comparators":[9],"(DCCs)":[10],"can":[11],"be":[12,39,93],"achieved":[13],"between":[14,98],"series":[15,100,133],"and":[16,54,75,84,95,101,129,160],"parallel":[17,102,134],"connections":[18],"n":[20,63],"sections":[21],"primary":[23,72],"windings":[24,43,73],"with":[25,41,106,120,149],"the":[26,42,67,71,79,81,88,99,132,145],"same":[27],"nominal":[28],"number":[29],"turns.":[31],"Based":[32],"on":[33,87],"this":[34],"principle,":[35],"a":[36],"DCC":[37,89],"could":[38],"calibrated":[40,130],"connected":[44],"in":[45,49],"series,":[46],"then":[47],"operated":[48],"parallel,":[50],"at":[51],"rated":[52],"therefore":[55],"have":[56,117],"its":[57],"ratio":[59,122],"accurately":[60],"extended":[61],"by":[62,131],"times.":[64],"By":[65],"keeping":[66],"geometric":[68],"position":[69],"symmetrically":[74],"rigidly":[76],"fixed":[77],"to":[78,113,127,156,165],"cores,":[80],"leakage":[82],"fluxes":[83],"their":[85],"effects":[86],"would":[92],"minimized":[94],"relatively":[96],"unchanged":[97],"connections.":[103],"Four":[104],"DCCs":[105,148],"10":[110,153],"A:1":[111,154],"A":[112,116,155,159],"5":[114,157],"kA:5":[115,158],"been":[118],"developed":[119],"relative":[121],"errors":[123],"less":[124],"than":[125],"2\u00d710-8":[126],"5\u00d710-7,":[128],"method":[135],"through":[136],"only":[137],"four":[138],"step":[139],"measurements.":[140],"These":[141],"measurement":[142],"techniques":[143],"for":[144],"self-calibration":[146],"corresponding":[161],"uncertainties":[162],"from":[163],"1.2\u00d710-8":[164],"1.6\u00d710-7(k=2)":[166],"are":[167],"described.":[168]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":2},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
