{"id":"https://openalex.org/W2020933128","doi":"https://doi.org/10.1109/tim.2013.2263660","title":"Mass Flow Rate Measurement of Oil-Water Two-Phase Flow by a Long-Waist Cone Meter","display_name":"Mass Flow Rate Measurement of Oil-Water Two-Phase Flow by a Long-Waist Cone Meter","publication_year":2013,"publication_date":"2013-06-17","ids":{"openalex":"https://openalex.org/W2020933128","doi":"https://doi.org/10.1109/tim.2013.2263660","mag":"2020933128"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2013.2263660","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2263660","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5068911557","display_name":"Chao Tan","orcid":"https://orcid.org/0000-0001-5146-4807"},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Chao Tan","raw_affiliation_strings":["Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin, China","Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China"],"affiliations":[{"raw_affiliation_string":"Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China","institution_ids":["https://openalex.org/I162868743"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072276579","display_name":"Hao Wu","orcid":"https://orcid.org/0000-0002-9423-198X"},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hao Wu","raw_affiliation_strings":["Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin, China","Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China"],"affiliations":[{"raw_affiliation_string":"Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China","institution_ids":["https://openalex.org/I162868743"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5025279788","display_name":"Feng Dong","orcid":"https://orcid.org/0000-0002-8478-8928"},"institutions":[{"id":"https://openalex.org/I162868743","display_name":"Tianjin University","ror":"https://ror.org/012tb2g32","country_code":"CN","type":"education","lineage":["https://openalex.org/I162868743"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Feng Dong","raw_affiliation_strings":["Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin, China","Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China"],"affiliations":[{"raw_affiliation_string":"Tianjin Key Laboratory of Process Measurement and Control, School of Electrical Engineering and Automation, Tianjin University, Tianjin, China","institution_ids":["https://openalex.org/I162868743"]},{"raw_affiliation_string":"Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China","institution_ids":["https://openalex.org/I162868743"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":["https://openalex.org/A5068911557"],"corresponding_institution_ids":["https://openalex.org/I162868743"],"apc_list":null,"apc_paid":null,"fwci":3.242,"has_fulltext":false,"cited_by_count":33,"citation_normalized_percentile":{"value":0.90280516,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":90,"max":98},"biblio":{"volume":"62","issue":"10","first_page":"2795","last_page":"2804"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13928","display_name":"Advanced Sensor Technologies Research","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11778","display_name":"Electrical and Bioimpedance Tomography","score":0.9939000010490417,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/mass-flow-meter","display_name":"Mass flow meter","score":0.8797413110733032},{"id":"https://openalex.org/keywords/flow-measurement","display_name":"Flow measurement","score":0.6916021108627319},{"id":"https://openalex.org/keywords/volumetric-flow-rate","display_name":"Volumetric flow rate","score":0.6639539003372192},{"id":"https://openalex.org/keywords/flow-coefficient","display_name":"Flow coefficient","score":0.5764467120170593},{"id":"https://openalex.org/keywords/mass-flow-rate","display_name":"Mass flow rate","score":0.5748430490493774},{"id":"https://openalex.org/keywords/two-phase-flow","display_name":"Two-phase flow","score":0.5002803802490234},{"id":"https://openalex.org/keywords/mass-flow","display_name":"Mass flow","score":0.49619680643081665},{"id":"https://openalex.org/keywords/flow","display_name":"Flow (mathematics)","score":0.4958370625972748},{"id":"https://openalex.org/keywords/positive-displacement-meter","display_name":"Positive displacement meter","score":0.4742152690887451},{"id":"https://openalex.org/keywords/mechanics","display_name":"Mechanics","score":0.46759718656539917},{"id":"https://openalex.org/keywords/thermal-mass-flow-meter","display_name":"Thermal mass flow meter","score":0.4370063543319702},{"id":"https://openalex.org/keywords/mathematics","display_name":"Mathematics","score":0.3808225989341736},{"id":"https://openalex.org/keywords/analytical-chemistry","display_name":"Analytical Chemistry (journal)","score":0.34305882453918457},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.31912779808044434},{"id":"https://openalex.org/keywords/chemistry","display_name":"Chemistry","score":0.20053598284721375},{"id":"https://openalex.org/keywords/chromatography","display_name":"Chromatography","score":0.11996066570281982}],"concepts":[{"id":"https://openalex.org/C175580448","wikidata":"https://www.wikidata.org/wiki/Q114414","display_name":"Mass flow meter","level":3,"score":0.8797413110733032},{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.6916021108627319},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.6639539003372192},{"id":"https://openalex.org/C143428516","wikidata":"https://www.wikidata.org/wiki/Q1794809","display_name":"Flow coefficient","level":3,"score":0.5764467120170593},{"id":"https://openalex.org/C75892298","wikidata":"https://www.wikidata.org/wiki/Q1366187","display_name":"Mass flow rate","level":2,"score":0.5748430490493774},{"id":"https://openalex.org/C144308804","wikidata":"https://www.wikidata.org/wiki/Q232997","display_name":"Two-phase flow","level":3,"score":0.5002803802490234},{"id":"https://openalex.org/C33493971","wikidata":"https://www.wikidata.org/wiki/Q3295893","display_name":"Mass flow","level":2,"score":0.49619680643081665},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4958370625972748},{"id":"https://openalex.org/C132643394","wikidata":"https://www.wikidata.org/wiki/Q7233264","display_name":"Positive displacement meter","level":2,"score":0.4742152690887451},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.46759718656539917},{"id":"https://openalex.org/C30198954","wikidata":"https://www.wikidata.org/wiki/Q4455290","display_name":"Thermal mass flow meter","level":4,"score":0.4370063543319702},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.3808225989341736},{"id":"https://openalex.org/C113196181","wikidata":"https://www.wikidata.org/wiki/Q485223","display_name":"Analytical Chemistry (journal)","level":2,"score":0.34305882453918457},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.31912779808044434},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.20053598284721375},{"id":"https://openalex.org/C43617362","wikidata":"https://www.wikidata.org/wiki/Q170050","display_name":"Chromatography","level":1,"score":0.11996066570281982}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2013.2263660","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2263660","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/6","score":0.7900000214576721,"display_name":"Clean water and sanitation"}],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W1504072055","https://openalex.org/W1602878425","https://openalex.org/W1970526552","https://openalex.org/W1986575450","https://openalex.org/W1988398493","https://openalex.org/W1994661118","https://openalex.org/W1996561803","https://openalex.org/W2000649967","https://openalex.org/W2001971677","https://openalex.org/W2002509590","https://openalex.org/W2002641761","https://openalex.org/W2007090477","https://openalex.org/W2009319608","https://openalex.org/W2009518490","https://openalex.org/W2034365247","https://openalex.org/W2037469096","https://openalex.org/W2040187035","https://openalex.org/W2044594594","https://openalex.org/W2082407166","https://openalex.org/W2082583257","https://openalex.org/W2093771285","https://openalex.org/W2128728167","https://openalex.org/W2160757332","https://openalex.org/W2350183063","https://openalex.org/W4205264441","https://openalex.org/W4238078318","https://openalex.org/W4245066122","https://openalex.org/W4285719527","https://openalex.org/W6636153159"],"related_works":["https://openalex.org/W2038672343","https://openalex.org/W2913736001","https://openalex.org/W3020923696","https://openalex.org/W1997857127","https://openalex.org/W2378501682","https://openalex.org/W2045641709","https://openalex.org/W2136896295","https://openalex.org/W2536636607","https://openalex.org/W2254355369","https://openalex.org/W2164901466"],"abstract_inverted_index":{"A":[0,13,39,82],"long-waist":[1,171],"cone":[2,172],"meter":[3,173],"is":[4,31,54,87,124],"proposed":[5,89],"for":[6,26,41,142,187],"horizontal":[7],"oil-water":[8,158],"two-phase":[9,74,159],"flow":[10,27,34,45,71,75,80,107,122,144,155,160],"rate":[11,28,35,46,72,123,156],"measurement.":[12,29],"constricting":[14],"differential":[15,21,51,84,130,177],"pressure":[16,22,52,85,131,178],"\u0394p":[17,30,61,96],"and":[18,62,100,115,139,145,174,192],"an":[19,134,165],"overall":[20,50,120,153],"\u03b4p":[23,53,63,101],"were":[24],"tapped":[25],"related":[32],"to":[33,67],"through":[36,56],"Bernoulli's":[37],"equation.":[38],"correlation":[40],"predicting":[42],"the":[43,49,69,78,92,110,128,152,175,181,188,193],"mass":[44,70,121,154],"by":[47,90,126,198],"using":[48,127],"presented":[55],"physical":[57],"analysis.":[58],"Correlations":[59],"of":[60,73,95,137,157,183],"are":[64,195],"then":[65,88],"extended":[66],"predict":[68],"based":[76],"on":[77,119],"separated":[79],"model.":[81],"dual":[83,129,176],"model":[86,132],"combining":[91],"two":[93],"correlations":[94],"<sub":[97,102],"xmlns:mml=\"http://www.w3.org/1998/Math/MathML\"":[98,103],"xmlns:xlink=\"http://www.w3.org/1999/xlink\">tp</sub>":[99,104],".":[105],"The":[106],"regimes":[108],"in":[109],"experiments":[111],"include":[112],"water":[113],"continuous":[114],"oil":[116],"continuous.":[117],"Prediction":[118],"improved":[125],"at":[133,164],"associated":[135],"error":[136],"2.7%":[138],"4.1%,":[140],"respectively,":[141],"water-continuous":[143],"oil-continuous":[146],"flow.":[147],"This":[148],"paper":[149],"indicates":[150],"that":[151],"can":[161],"be":[162],"determined":[163],"accuracy":[166],"within":[167],"\u00b15%":[168],"with":[169],"a":[170,184],"models":[179],"without":[180],"aid":[182],"secondary":[185],"instrument":[186],"phase":[189,199],"fraction":[190],"measurement,":[191],"results":[194],"less":[196],"affected":[197],"inversion.":[200]},"counts_by_year":[{"year":2025,"cited_by_count":2},{"year":2024,"cited_by_count":3},{"year":2022,"cited_by_count":6},{"year":2021,"cited_by_count":6},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":1},{"year":2017,"cited_by_count":2},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":3}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
