{"id":"https://openalex.org/W2060040417","doi":"https://doi.org/10.1109/tim.2013.2259114","title":"ICA-Based Improved DTCWT Technique for MA Reduction in PPG Signals With Restored Respiratory Information","display_name":"ICA-Based Improved DTCWT Technique for MA Reduction in PPG Signals With Restored Respiratory Information","publication_year":2013,"publication_date":"2013-06-03","ids":{"openalex":"https://openalex.org/W2060040417","doi":"https://doi.org/10.1109/tim.2013.2259114","mag":"2060040417"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2013.2259114","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2259114","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5108543671","display_name":"M. Raghu Ram","orcid":null},"institutions":[{"id":"https://openalex.org/I28210344","display_name":"Kakatiya University","ror":"https://ror.org/012zpbg81","country_code":"IN","type":"education","lineage":["https://openalex.org/I28210344"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"M. Raghu Ram","raw_affiliation_strings":["Department of Electronics and Instrumentation Engineering, Kakatiya Institute of Technology and Science, Warangal, Andhra Pradesh, India","Dept. of Electron. & Instrum. Eng., Kakatiya Inst. of Technol. & Sci., Warangal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Instrumentation Engineering, Kakatiya Institute of Technology and Science, Warangal, Andhra Pradesh, India","institution_ids":["https://openalex.org/I28210344"]},{"raw_affiliation_string":"Dept. of Electron. & Instrum. Eng., Kakatiya Inst. of Technol. & Sci., Warangal, India","institution_ids":["https://openalex.org/I28210344"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112838246","display_name":"K. Venu Madhav","orcid":null},"institutions":[{"id":"https://openalex.org/I28210344","display_name":"Kakatiya University","ror":"https://ror.org/012zpbg81","country_code":"IN","type":"education","lineage":["https://openalex.org/I28210344"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"K. Venu Madhav","raw_affiliation_strings":["Department of Electronics and Instrumentation Engineering, Kakatiya Institute of Technology and Science, Warangal, Andhra Pradesh, India","Dept. of Electron. & Instrum. Eng., Kakatiya Inst. of Technol. & Sci., Warangal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Instrumentation Engineering, Kakatiya Institute of Technology and Science, Warangal, Andhra Pradesh, India","institution_ids":["https://openalex.org/I28210344"]},{"raw_affiliation_string":"Dept. of Electron. & Instrum. Eng., Kakatiya Inst. of Technol. & Sci., Warangal, India","institution_ids":["https://openalex.org/I28210344"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074340054","display_name":"E. Hari Krishna","orcid":"https://orcid.org/0000-0001-6668-7245"},"institutions":[{"id":"https://openalex.org/I121750182","display_name":"National Institute of Technology Warangal","ror":"https://ror.org/017ebfz38","country_code":"IN","type":"education","lineage":["https://openalex.org/I121750182"]},{"id":"https://openalex.org/I28210344","display_name":"Kakatiya University","ror":"https://ror.org/012zpbg81","country_code":"IN","type":"education","lineage":["https://openalex.org/I28210344"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ette Hari Krishna","raw_affiliation_strings":["Department of Electronics and Communication Engineering, Kakatiya University College of Engineering and Technology, Warangal, Andhra Pradesh, India","Dept. of Electron. & Commun. Eng., KU Coll. of Eng. & Technol., Warangal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication Engineering, Kakatiya University College of Engineering and Technology, Warangal, Andhra Pradesh, India","institution_ids":["https://openalex.org/I28210344"]},{"raw_affiliation_string":"Dept. of Electron. & Commun. Eng., KU Coll. of Eng. & Technol., Warangal, India","institution_ids":["https://openalex.org/I121750182"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5019391678","display_name":"Nagarjuna Reddy Komalla","orcid":"https://orcid.org/0000-0002-4943-9669"},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Nagarjuna Reddy Komalla","raw_affiliation_strings":["Department of Anaesthesiology, Government Maternity Hospitals, Hanamkonda, Andhra Pradesh, India","Dept. of Anaesthesiology, Gov. Maternity Hosp., Hanamkonda, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Anaesthesiology, Government Maternity Hospitals, Hanamkonda, Andhra Pradesh, India","institution_ids":[]},{"raw_affiliation_string":"Dept. of Anaesthesiology, Gov. Maternity Hosp., Hanamkonda, India","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042982346","display_name":"K. Sivani","orcid":"https://orcid.org/0000-0001-7412-1866"},"institutions":[{"id":"https://openalex.org/I94415630","display_name":"Sri Padmavati Mahila Visvavidyalayam","ror":"https://ror.org/02zptxe07","country_code":"IN","type":"education","lineage":["https://openalex.org/I94415630"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Kosaraju Sivani","raw_affiliation_strings":["Department of Electronics and Communication Engineering, Talla Padmavathi College of Engineering, Warangal, Andhra Pradesh, India","Dept. of Electron. & Commun. Eng., Talla Padmavathi Coll. of Eng., Warangal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Communication Engineering, Talla Padmavathi College of Engineering, Warangal, Andhra Pradesh, India","institution_ids":["https://openalex.org/I94415630"]},{"raw_affiliation_string":"Dept. of Electron. & Commun. Eng., Talla Padmavathi Coll. of Eng., Warangal, India","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5108078990","display_name":"K. Ashoka Reddy","orcid":null},"institutions":[{"id":"https://openalex.org/I28210344","display_name":"Kakatiya University","ror":"https://ror.org/012zpbg81","country_code":"IN","type":"education","lineage":["https://openalex.org/I28210344"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"K. Ashoka Reddy","raw_affiliation_strings":["Department of Electronics and Instrumentation Engineering, Kakatiya Institute of Technology and Science, Warangal, Andhra Pradesh, India","Dept. of Electron. & Instrum. Eng., Kakatiya Inst. of Technol. & Sci., Warangal, India"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electronics and Instrumentation Engineering, Kakatiya Institute of Technology and Science, Warangal, Andhra Pradesh, India","institution_ids":["https://openalex.org/I28210344"]},{"raw_affiliation_string":"Dept. of Electron. & Instrum. Eng., Kakatiya Inst. of Technol. & Sci., Warangal, India","institution_ids":["https://openalex.org/I28210344"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":3,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.9405,"has_fulltext":false,"cited_by_count":51,"citation_normalized_percentile":{"value":0.84856723,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":94,"max":99},"biblio":{"volume":"62","issue":"10","first_page":"2639","last_page":"2651"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11021","display_name":"ECG Monitoring and Analysis","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10429","display_name":"EEG and Brain-Computer Interfaces","score":0.9937999844551086,"subfield":{"id":"https://openalex.org/subfields/2805","display_name":"Cognitive Neuroscience"},"field":{"id":"https://openalex.org/fields/28","display_name":"Neuroscience"},"domain":{"id":"https://openalex.org/domains/1","display_name":"Life Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/artificial-intelligence","display_name":"Artificial intelligence","score":0.666519284248352},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.5307251214981079},{"id":"https://openalex.org/keywords/complex-wavelet-transform","display_name":"Complex wavelet transform","score":0.5065032243728638},{"id":"https://openalex.org/keywords/independent-component-analysis","display_name":"Independent component analysis","score":0.5006542205810547},{"id":"https://openalex.org/keywords/pattern-recognition","display_name":"Pattern recognition (psychology)","score":0.47806695103645325},{"id":"https://openalex.org/keywords/wavelet-transform","display_name":"Wavelet transform","score":0.2821241617202759},{"id":"https://openalex.org/keywords/wavelet","display_name":"Wavelet","score":0.17992988228797913},{"id":"https://openalex.org/keywords/discrete-wavelet-transform","display_name":"Discrete wavelet transform","score":0.15165090560913086}],"concepts":[{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.666519284248352},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5307251214981079},{"id":"https://openalex.org/C2777885455","wikidata":"https://www.wikidata.org/wiki/Q5156615","display_name":"Complex wavelet transform","level":5,"score":0.5065032243728638},{"id":"https://openalex.org/C51432778","wikidata":"https://www.wikidata.org/wiki/Q1259145","display_name":"Independent component analysis","level":2,"score":0.5006542205810547},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.47806695103645325},{"id":"https://openalex.org/C196216189","wikidata":"https://www.wikidata.org/wiki/Q2867","display_name":"Wavelet transform","level":3,"score":0.2821241617202759},{"id":"https://openalex.org/C47432892","wikidata":"https://www.wikidata.org/wiki/Q831390","display_name":"Wavelet","level":2,"score":0.17992988228797913},{"id":"https://openalex.org/C46286280","wikidata":"https://www.wikidata.org/wiki/Q2414958","display_name":"Discrete wavelet transform","level":4,"score":0.15165090560913086}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2013.2259114","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2259114","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320719","display_name":"Department of Science and Technology, Ministry of Science and Technology, India","ror":"https://ror.org/0101xrq71"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":32,"referenced_works":["https://openalex.org/W1976272555","https://openalex.org/W1996314835","https://openalex.org/W2006752824","https://openalex.org/W2014322746","https://openalex.org/W2015466827","https://openalex.org/W2018332268","https://openalex.org/W2053277433","https://openalex.org/W2055279385","https://openalex.org/W2074667327","https://openalex.org/W2086248190","https://openalex.org/W2101394537","https://openalex.org/W2103675325","https://openalex.org/W2104164259","https://openalex.org/W2114984772","https://openalex.org/W2115093732","https://openalex.org/W2117987876","https://openalex.org/W2123601657","https://openalex.org/W2124669095","https://openalex.org/W2140147284","https://openalex.org/W2146587431","https://openalex.org/W2150597948","https://openalex.org/W2155589764","https://openalex.org/W2159079926","https://openalex.org/W2160369805","https://openalex.org/W2162656426","https://openalex.org/W2165013639","https://openalex.org/W2168688029","https://openalex.org/W2171380770","https://openalex.org/W2536456252","https://openalex.org/W4232851490","https://openalex.org/W6675764344","https://openalex.org/W6683972800"],"related_works":["https://openalex.org/W2384899824","https://openalex.org/W2087721185","https://openalex.org/W1564859343","https://openalex.org/W2162109371","https://openalex.org/W2033914206","https://openalex.org/W2042327336","https://openalex.org/W2349759295","https://openalex.org/W12409041","https://openalex.org/W2098128922","https://openalex.org/W2373146287"],"abstract_inverted_index":{"In":[0,272],"addition":[1],"to":[2,43,265,283,300],"estimation":[3],"of":[4,71,82,86,107,138,168,194,205,230,267,270],"arterial":[5,313],"blood":[6],"oxygen":[7],"saturation":[8,238],"(SpO2),":[9],"pulse":[10,100,232,289],"oximeter's":[11],"photoplethysmographic":[12],"(PPG)":[13],"signals":[14],"can":[15],"be":[16],"well":[17,225],"utilized":[18],"for":[19,50,68,234,310],"extracting":[20],"the":[21,51,74,136,159,198,224,236,242,251,256,274,284,305,312],"vital":[22],"respiratory":[23,45,75,206],"information.":[24,46],"The":[25,78,185,215,245],"motion":[26],"artifacts":[27],"(MA)":[28],"in":[29,142,155,166,192,278],"PPGs":[30,249,299],"not":[31],"only":[32],"make":[33,40],"SpO2estimations":[34],"unreliable":[35],"and":[36,104,111,130,146,178,197,261,304],"inaccurate":[37],"but":[38],"also":[39,219,294],"it":[41],"difficult":[42],"extract":[44],"Addressing":[47],"this":[48],"issue,":[49],"first":[52],"time,":[53],"we":[54],"propose":[55],"a":[56,151],"novel":[57],"approach":[58],"called":[59],"\u201cICA-based":[60],"improved":[61],"dual-tree":[62],"complex":[63],"wavelet":[64],"transform":[65,239],"(I2DTCWT)\u201d":[66],"technique,":[67],"efficient":[69,94],"reduction":[70,196],"MAs":[72,125,157],"leaving":[73],"information":[76,207],"undisturbed.":[77],"method":[79,217,253,276],"makes":[80],"use":[81],"source":[83],"separation":[84],"ability":[85],"independent":[87],"component":[88],"analysis":[89,106,180,292],"(ICA)":[90],"along":[91],"with":[92,122,158,181,223],"computationally":[93],"modified":[95,109],"DTCWT":[96,110,139,189],"processing.":[97],"A":[98],"prototype":[99],"oximeter":[101],"was":[102,115],"developed":[103],"performance":[105,163],"DTCWT,":[108],"I2DTCWT":[112,186],"processing":[113,140,190],"methods":[114,141,191],"carried":[116],"out":[117],"using":[118],"PPG":[119,144,302],"data":[120],"recorded":[121],"intentionally":[123],"created":[124],"(horizontal":[126],"MA,":[127,129],"vertical":[128],"bending":[131],"MA).":[132],"Experimental":[133],"results":[134],"demonstrated":[135],"efficiency":[137],"restoring":[143],"morphology":[145,303],"proved":[147],"that":[148,202,266],"there":[149],"is":[150,164,208,218,241,293],"significant":[152],"improvement":[153],"guaranteed":[154,209],"reducing":[156],"presented":[160],"methods.":[161],"Statistical":[162],"evaluated":[165],"terms":[167],"measures":[169],"like":[170],"signal-to-noise":[171],"ratio,":[172],"normalized":[173],"root":[174],"mean":[175],"square":[176],"error,":[177],"correlation":[179,182],"co-efficient":[183],"measure.":[184],"outperformed":[187],"other":[188],"respect":[193],"MA":[195,212,297],"computed":[199],"spectra":[200],"revealed":[201],"safe":[203],"extraction":[204,228],"from":[210,247],"these":[211],"reduced":[213,298],"PPGs.":[214],"proposed":[216,252,275],"validated":[220],"by":[221,250],"comparing":[222],"established":[226],"signal":[227],"technology":[229],"MASIMO":[231,285],"oximeters,":[233],"which":[235],"discrete":[237],"(DST)":[240],"key":[243],"element.":[244],"%SpO2estimations":[246],"processed":[248],"closely":[254],"followed":[255],"estimations":[257],"based":[258],"on":[259,296],"DST":[260],"were":[262],"very":[263],"close":[264],"clean":[268],"sections":[269],"PPG.":[271],"addition,":[273],"resulted":[277],"less":[279],"computation":[280],"cost":[281],"compared":[282],"SET.":[286],"Digital":[287],"volume":[288],"waveform":[290],"contour":[291],"performed":[295],"validate":[301],"conventional":[306],"parameters":[307],"are":[308],"calculated":[309],"assessing":[311],"stiffness.":[314]},"counts_by_year":[{"year":2025,"cited_by_count":3},{"year":2024,"cited_by_count":2},{"year":2023,"cited_by_count":4},{"year":2022,"cited_by_count":5},{"year":2021,"cited_by_count":7},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":3},{"year":2018,"cited_by_count":3},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":6},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":2}],"updated_date":"2026-07-29T09:40:50.615796","created_date":"2025-10-10T00:00:00"}
