{"id":"https://openalex.org/W2068425990","doi":"https://doi.org/10.1109/tim.2013.2258239","title":"Absolute Measurement of Current Dependence in DC Resistors by a Double Current Method","display_name":"Absolute Measurement of Current Dependence in DC Resistors by a Double Current Method","publication_year":2013,"publication_date":"2013-06-06","ids":{"openalex":"https://openalex.org/W2068425990","doi":"https://doi.org/10.1109/tim.2013.2258239","mag":"2068425990"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2013.2258239","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2258239","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5001452215","display_name":"Haiming Shao","orcid":"https://orcid.org/0000-0002-3305-4190"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Haiming Shao","raw_affiliation_strings":["National Institute of Metrology, Beijing, China","Nat. Inst. of Metrol., Beijing, China"],"affiliations":[{"raw_affiliation_string":"National Institute of Metrology, Beijing, China","institution_ids":["https://openalex.org/I4210162136"]},{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040854060","display_name":"Bo Liang","orcid":"https://orcid.org/0000-0001-6977-7967"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Bo Liang","raw_affiliation_strings":["National Institute of Metrology, Beijing, China","Nat. Inst. of Metrol., Beijing, China"],"affiliations":[{"raw_affiliation_string":"National Institute of Metrology, Beijing, China","institution_ids":["https://openalex.org/I4210162136"]},{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102979842","display_name":"Feipeng Lin","orcid":"https://orcid.org/0000-0002-1108-1622"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Feipeng Lin","raw_affiliation_strings":["National Institute of Metrology, Beijing, China","Nat. Inst. of Metrol., Beijing, China"],"affiliations":[{"raw_affiliation_string":"National Institute of Metrology, Beijing, China","institution_ids":["https://openalex.org/I4210162136"]},{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108260409","display_name":"Hongtao Huang","orcid":"https://orcid.org/0009-0002-1622-3586"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hongtao Huang","raw_affiliation_strings":["National Institute of Metrology, Beijing, China","Nat. Inst. of Metrol., Beijing, China"],"affiliations":[{"raw_affiliation_string":"National Institute of Metrology, Beijing, China","institution_ids":["https://openalex.org/I4210162136"]},{"raw_affiliation_string":"Nat. Inst. of Metrol., Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5089393911","display_name":"Yanqiang Li","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123506","display_name":"Jiangsu Institute of Metrology","ror":"https://ror.org/035hazd92","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210123506"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yanqiang Li","raw_affiliation_strings":["Shanxi Institute of Metrology, Taiyuan, China","Shanxi Inst. of Metrol., Taiyuan, China"],"affiliations":[{"raw_affiliation_string":"Shanxi Institute of Metrology, Taiyuan, China","institution_ids":["https://openalex.org/I4210123506"]},{"raw_affiliation_string":"Shanxi Inst. of Metrol., Taiyuan, China","institution_ids":["https://openalex.org/I4210123506"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5033589941","display_name":"Kai Jia","orcid":"https://orcid.org/0000-0001-7498-3482"},"institutions":[{"id":"https://openalex.org/I82880672","display_name":"Beihang University","ror":"https://ror.org/00wk2mp56","country_code":"CN","type":"education","lineage":["https://openalex.org/I82880672"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kai Jia","raw_affiliation_strings":["School of Automation Science and Electrical Engineering, Beihang University, Beijing, China","Sch. of Autom. Sci. & Electr. Eng, Beihang Univ., Beijing, , China"],"affiliations":[{"raw_affiliation_string":"School of Automation Science and Electrical Engineering, Beihang University, Beijing, China","institution_ids":["https://openalex.org/I82880672"]},{"raw_affiliation_string":"Sch. of Autom. Sci. & Electr. Eng, Beihang Univ., Beijing, , China","institution_ids":["https://openalex.org/I82880672"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100333973","display_name":"Wenfeng Li","orcid":"https://orcid.org/0000-0003-3823-9570"},"institutions":[{"id":"https://openalex.org/I78675632","display_name":"Beijing Information Science & Technology University","ror":"https://ror.org/04xnqep60","country_code":"CN","type":"education","lineage":["https://openalex.org/I78675632"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wenfeng Li","raw_affiliation_strings":["Beijing Information Science and Technology University, Beijing, China","Beijing Information Science and Technology University,Beijing,CHINA"],"affiliations":[{"raw_affiliation_string":"Beijing Information Science and Technology University, Beijing, China","institution_ids":["https://openalex.org/I78675632"]},{"raw_affiliation_string":"Beijing Information Science and Technology University,Beijing,CHINA","institution_ids":["https://openalex.org/I78675632"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5074000379","display_name":"Huanghui Zhang","orcid":"https://orcid.org/0000-0003-3412-6763"},"institutions":[{"id":"https://openalex.org/I4210109881","display_name":"Fujian Metrology Institute","ror":"https://ror.org/017y22r40","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210109881"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Huanghui Zhang","raw_affiliation_strings":["Fujian Institute of Meteorological Science, Fuzhou, China","Fujian Inst. of Metrol., Fuzhou, China"],"affiliations":[{"raw_affiliation_string":"Fujian Institute of Meteorological Science, Fuzhou, China","institution_ids":[]},{"raw_affiliation_string":"Fujian Inst. of Metrol., Fuzhou, China","institution_ids":["https://openalex.org/I4210109881"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":8,"corresponding_author_ids":["https://openalex.org/A5001452215"],"corresponding_institution_ids":["https://openalex.org/I4210162136"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.12195507,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"62","issue":"8","first_page":"2323","last_page":"2329"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10323","display_name":"Analog and Mixed-Signal Circuit Design","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10558","display_name":"Advancements in Semiconductor Devices and Circuit Design","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/resistor","display_name":"Resistor","score":0.9404394626617432},{"id":"https://openalex.org/keywords/current","display_name":"Current (fluid)","score":0.6869767904281616},{"id":"https://openalex.org/keywords/resistive-touchscreen","display_name":"Resistive touchscreen","score":0.5939432382583618},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5554359555244446},{"id":"https://openalex.org/keywords/comparator","display_name":"Comparator","score":0.4896319508552551},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.44809088110923767},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.430439829826355},{"id":"https://openalex.org/keywords/volt-ampere","display_name":"Volt-ampere","score":0.4131864905357361},{"id":"https://openalex.org/keywords/power-factor","display_name":"Power factor","score":0.3200218081474304},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2930404543876648},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.2884383201599121},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.17491868138313293},{"id":"https://openalex.org/keywords/constant-power-circuit","display_name":"Constant power circuit","score":0.1320258378982544}],"concepts":[{"id":"https://openalex.org/C137488568","wikidata":"https://www.wikidata.org/wiki/Q5321","display_name":"Resistor","level":3,"score":0.9404394626617432},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.6869767904281616},{"id":"https://openalex.org/C6899612","wikidata":"https://www.wikidata.org/wiki/Q852911","display_name":"Resistive touchscreen","level":2,"score":0.5939432382583618},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5554359555244446},{"id":"https://openalex.org/C155745195","wikidata":"https://www.wikidata.org/wiki/Q1164179","display_name":"Comparator","level":3,"score":0.4896319508552551},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.44809088110923767},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.430439829826355},{"id":"https://openalex.org/C148367217","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere","level":5,"score":0.4131864905357361},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.3200218081474304},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2930404543876648},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2884383201599121},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.17491868138313293},{"id":"https://openalex.org/C29586797","wikidata":"https://www.wikidata.org/wiki/Q5163663","display_name":"Constant power circuit","level":4,"score":0.1320258378982544},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2013.2258239","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2258239","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8700000047683716,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320311508","display_name":"National Institute of Advanced Industrial Science and Technology","ror":"https://ror.org/01703db54"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":8,"referenced_works":["https://openalex.org/W1989048038","https://openalex.org/W2011295589","https://openalex.org/W2096203650","https://openalex.org/W2155733266","https://openalex.org/W2178976913","https://openalex.org/W2348296801","https://openalex.org/W2375410909","https://openalex.org/W7052720710"],"related_works":["https://openalex.org/W1544605947","https://openalex.org/W2084796212","https://openalex.org/W2382426850","https://openalex.org/W1984102208","https://openalex.org/W2293861156","https://openalex.org/W2350865575","https://openalex.org/W4293490268","https://openalex.org/W3134581561","https://openalex.org/W2349482209","https://openalex.org/W2056437737"],"abstract_inverted_index":{"A":[0],"double":[1],"current":[2,11,27,42,85,94],"method":[3,110],"is":[4,48,78,89],"presented":[5,109],"for":[6],"absolute":[7,82],"measurements":[8,54],"of":[9,15,24,71,84,92,96],"the":[10,20,40,69,76,93,108],"dependence":[12,95],"(power":[13],"variation)":[14],"dc":[16],"resistors.":[17],"Based":[18],"on":[19],"resistance":[21,72],"measurement":[22,83],"principle":[23],"a":[25,36],"direct":[26],"comparator":[28],"(DCC),":[29],"and":[30,111],"adding":[31],"another":[32],"DCC-based":[33],"extender":[34],"with":[35,55],"turn":[37],"ratio":[38],"1:1,":[39],"testing":[41],"in":[43,61],"resistors":[44,59,104],"to":[45],"be":[46],"tested":[47],"accurately":[49],"doubled.":[50],"Through":[51],"three":[52],"comparative":[53],"two":[56],"reference":[57],"standard":[58,103],"connected":[60],"series":[62],"as":[63],"Kelvin":[64],"resistive":[65],"bridge":[66],"inner":[67],"arms,":[68],"change":[70],"caused":[73],"by":[74],"doubling":[75],"currents":[77],"measured.":[79],"Cyclically":[80],"done,":[81],"or":[86],"power":[87],"factor":[88],"realized.":[90],"Examples":[91],"some":[97],"commercial":[98],"low-temperature":[99],"coefficient":[100],"1":[101],"\u03a9":[102],"are":[105,114],"given":[106],"using":[107],"their":[112],"results":[113],"analyzed.":[115]},"counts_by_year":[],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
