{"id":"https://openalex.org/W2149683966","doi":"https://doi.org/10.1109/tim.2013.2250191","title":"Improvement of High-Value Capacitance Measurement","display_name":"Improvement of High-Value Capacitance Measurement","publication_year":2013,"publication_date":"2013-03-27","ids":{"openalex":"https://openalex.org/W2149683966","doi":"https://doi.org/10.1109/tim.2013.2250191","mag":"2149683966"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2013.2250191","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2250191","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5014953276","display_name":"Dongxue Dai","orcid":"https://orcid.org/0000-0002-1196-5508"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Dai DongXue","raw_affiliation_strings":["National Institute of Metrology, Beijing, China"],"affiliations":[{"raw_affiliation_string":"National Institute of Metrology, Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5109202285","display_name":"Xiaobing He","orcid":null},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"He XiaoBing","raw_affiliation_strings":["National Institute of Metrology, Beijing, China"],"affiliations":[{"raw_affiliation_string":"National Institute of Metrology, Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5116337743","display_name":"Wei Wang","orcid":"https://orcid.org/0000-0003-1568-222X"},"institutions":[{"id":"https://openalex.org/I4210162136","display_name":"National Institute of Metrology","ror":"https://ror.org/05dw0p167","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210162136"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Wang Wei","raw_affiliation_strings":["National Institute of Metrology, Beijing, China"],"affiliations":[{"raw_affiliation_string":"National Institute of Metrology, Beijing, China","institution_ids":["https://openalex.org/I4210162136"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5082022889","display_name":"YanQiang Li","orcid":null},"institutions":[{"id":"https://openalex.org/I4210123506","display_name":"Jiangsu Institute of Metrology","ror":"https://ror.org/035hazd92","country_code":"CN","type":"other","lineage":["https://openalex.org/I4210123506"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Li YanQiang","raw_affiliation_strings":["Shanxi Institute of Metrology, Taiyuan, China"],"affiliations":[{"raw_affiliation_string":"Shanxi Institute of Metrology, Taiyuan, China","institution_ids":["https://openalex.org/I4210123506"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5014953276"],"corresponding_institution_ids":["https://openalex.org/I4210162136"],"apc_list":null,"apc_paid":null,"fwci":0.2364,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.63322593,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"62","issue":"6","first_page":"1795","last_page":"1800"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9998999834060669,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.9986000061035156,"subfield":{"id":"https://openalex.org/subfields/1705","display_name":"Computer Networks and Communications"},"field":{"id":"https://openalex.org/fields/17","display_name":"Computer Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12510","display_name":"Magneto-Optical Properties and Applications","score":0.9943000078201294,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/resistor","display_name":"Resistor","score":0.8821588754653931},{"id":"https://openalex.org/keywords/capacitor","display_name":"Capacitor","score":0.8432961702346802},{"id":"https://openalex.org/keywords/capacitance","display_name":"Capacitance","score":0.8230788707733154},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.6015574336051941},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.5696424841880798},{"id":"https://openalex.org/keywords/shunt","display_name":"Shunt (medical)","score":0.5218390822410583},{"id":"https://openalex.org/keywords/materials-science","display_name":"Materials science","score":0.4300251007080078},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.42741259932518005},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.4220362901687622},{"id":"https://openalex.org/keywords/acoustics","display_name":"Acoustics","score":0.34783193469047546},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.3115191161632538},{"id":"https://openalex.org/keywords/physics","display_name":"Physics","score":0.2891842722892761},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.28522634506225586},{"id":"https://openalex.org/keywords/electrode","display_name":"Electrode","score":0.12125897407531738}],"concepts":[{"id":"https://openalex.org/C137488568","wikidata":"https://www.wikidata.org/wiki/Q5321","display_name":"Resistor","level":3,"score":0.8821588754653931},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.8432961702346802},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.8230788707733154},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6015574336051941},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5696424841880798},{"id":"https://openalex.org/C2780968331","wikidata":"https://www.wikidata.org/wiki/Q1890115","display_name":"Shunt (medical)","level":2,"score":0.5218390822410583},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4300251007080078},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.42741259932518005},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4220362901687622},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.34783193469047546},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3115191161632538},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2891842722892761},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28522634506225586},{"id":"https://openalex.org/C17525397","wikidata":"https://www.wikidata.org/wiki/Q176140","display_name":"Electrode","level":2,"score":0.12125897407531738},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C164705383","wikidata":"https://www.wikidata.org/wiki/Q10379","display_name":"Cardiology","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tim.2013.2250191","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2013.2250191","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.8600000143051147,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"awards":[],"funders":[{"id":"https://openalex.org/F4320331086","display_name":"National Institute of Metrology, China","ror":"https://ror.org/05dw0p167"},{"id":"https://openalex.org/F4320334904","display_name":"National Institute for Materials Science","ror":"https://ror.org/026v1ze26"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":5,"referenced_works":["https://openalex.org/W2125550508","https://openalex.org/W2125750759","https://openalex.org/W2125998692","https://openalex.org/W4242547654","https://openalex.org/W6678927145"],"related_works":["https://openalex.org/W3200817179","https://openalex.org/W1960166976","https://openalex.org/W2380067098","https://openalex.org/W2080773395","https://openalex.org/W3212531278","https://openalex.org/W2099626417","https://openalex.org/W2019514496","https://openalex.org/W2085450379","https://openalex.org/W3129126528","https://openalex.org/W2354552488"],"abstract_inverted_index":{"An":[0,29],"improved":[1],"method":[2],"of":[3,80],"measuring":[4],"high-value":[5],"capacitors":[6],"based":[7],"on":[8],"sampling":[9],"technology":[10],"is":[11,19,32],"presented":[12],"in":[13,40],"this":[14],"letter.":[15],"A":[16],"standard":[17],"resistor":[18,48],"used":[20,33],"as":[21],"reference":[22],"at":[23,52,78],"its":[24],"resistance":[25],"and":[26,46,65,75,85],"time":[27],"constant.":[28],"inductive":[30,60],"shunt":[31],"to":[34],"produce":[35],"two":[36],"precisely":[37],"equal":[38],"currents":[39],"parallel":[41],"so":[42],"that":[43],"the":[44,47,59,62],"capacitor":[45],"can":[49],"be":[50],"measured":[51,63],"ground":[53],"potential.":[54],"The":[55],"calibration":[56],"procedure":[57],"for":[58,70],"shunt,":[61],"results,":[64],"their":[66],"uncertainty":[67],"are":[68],"reported":[69],"10":[71],"\\mmb\u03bcF,":[72,74],"100":[73,81],"1":[76,86],"mF":[77],"frequencies":[79],"Hz,":[82],"120":[83],"Hz":[84],"kHz.":[87]},"counts_by_year":[{"year":2018,"cited_by_count":2},{"year":2017,"cited_by_count":2},{"year":2014,"cited_by_count":1}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}
