{"id":"https://openalex.org/W2171992165","doi":"https://doi.org/10.1109/tim.2011.2115650","title":"Electronic Combined Transformer for Power-Quality Measurements in High-Voltage Systems","display_name":"Electronic Combined Transformer for Power-Quality Measurements in High-Voltage Systems","publication_year":2011,"publication_date":"2011-03-15","ids":{"openalex":"https://openalex.org/W2171992165","doi":"https://doi.org/10.1109/tim.2011.2115650","mag":"2171992165"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2011.2115650","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2011.2115650","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5001972308","display_name":"Marco Faifer","orcid":"https://orcid.org/0000-0002-8777-5444"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"M Faifer","raw_affiliation_strings":["Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003675815","display_name":"Sergio Toscani","orcid":"https://orcid.org/0000-0003-2317-5818"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"S Toscani","raw_affiliation_strings":["Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5017740145","display_name":"Roberto Ottoboni","orcid":"https://orcid.org/0000-0002-5371-1346"},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"R Ottoboni","raw_affiliation_strings":["Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dipartimento di Elettrotecnica, Politecnico di Milano, Milan, Italy","institution_ids":["https://openalex.org/I93860229"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I93860229"],"apc_list":null,"apc_paid":null,"fwci":4.2603,"has_fulltext":false,"cited_by_count":55,"citation_normalized_percentile":{"value":0.94655668,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":89,"max":99},"biblio":{"volume":"60","issue":"6","first_page":"2007","last_page":"2013"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12692","display_name":"Magnetic Field Sensors Techniques","score":0.9997000098228455,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12169","display_name":"Non-Destructive Testing Techniques","score":0.9995999932289124,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/current-transformer","display_name":"Current transformer","score":0.721440315246582},{"id":"https://openalex.org/keywords/electrical-engineering","display_name":"Electrical engineering","score":0.630065381526947},{"id":"https://openalex.org/keywords/transformer","display_name":"Transformer","score":0.5557926893234253},{"id":"https://openalex.org/keywords/electronic-engineering","display_name":"Electronic engineering","score":0.5451698303222656},{"id":"https://openalex.org/keywords/voltage","display_name":"Voltage","score":0.5278810262680054},{"id":"https://openalex.org/keywords/engineering","display_name":"Engineering","score":0.48392802476882935},{"id":"https://openalex.org/keywords/capacitive-sensing","display_name":"Capacitive sensing","score":0.482954204082489},{"id":"https://openalex.org/keywords/electronics","display_name":"Electronics","score":0.47929826378822327},{"id":"https://openalex.org/keywords/distribution-transformer","display_name":"Distribution transformer","score":0.44570010900497437},{"id":"https://openalex.org/keywords/power-electronics","display_name":"Power electronics","score":0.4456600546836853},{"id":"https://openalex.org/keywords/current-sensor","display_name":"Current sensor","score":0.4380204677581787},{"id":"https://openalex.org/keywords/low-voltage","display_name":"Low voltage","score":0.4333977699279785},{"id":"https://openalex.org/keywords/high-voltage","display_name":"High voltage","score":0.414320170879364},{"id":"https://openalex.org/keywords/computer-science","display_name":"Computer science","score":0.35157039761543274}],"concepts":[{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.721440315246582},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.630065381526947},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5557926893234253},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.5451698303222656},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.5278810262680054},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.48392802476882935},{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.482954204082489},{"id":"https://openalex.org/C138331895","wikidata":"https://www.wikidata.org/wiki/Q11650","display_name":"Electronics","level":2,"score":0.47929826378822327},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.44570010900497437},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.4456600546836853},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.4380204677581787},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.4333977699279785},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.414320170879364},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.35157039761543274}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/tim.2011.2115650","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2011.2115650","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:re.public.polimi.it:11311/583149","is_oa":false,"landing_page_url":"http://hdl.handle.net/11311/583149","pdf_url":null,"source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":null,"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":11,"referenced_works":["https://openalex.org/W2079071820","https://openalex.org/W2095727143","https://openalex.org/W2131768584","https://openalex.org/W2137457845","https://openalex.org/W2149970231","https://openalex.org/W2156002823","https://openalex.org/W2164167317","https://openalex.org/W2172306131","https://openalex.org/W2532648025","https://openalex.org/W2594154706","https://openalex.org/W4254031689"],"related_works":["https://openalex.org/W2899084033","https://openalex.org/W2107284685","https://openalex.org/W2350175534","https://openalex.org/W2352083833","https://openalex.org/W3154423550","https://openalex.org/W3171586457","https://openalex.org/W1589064239","https://openalex.org/W2388362859","https://openalex.org/W2167413948","https://openalex.org/W3199725833"],"abstract_inverted_index":{"The":[0,108,172],"evolution":[1],"of":[2,21,55,59,82,85,99,114,117,182,190],"electronic":[3,89,141],"technology":[4],"and":[5,13,18,53,102,105,129,134,143,185,201,210,214,220],"digital":[6],"signal":[7],"processing":[8],"is":[9,111,150,195],"making":[10],"competitive":[11],"methods":[12],"devices":[14,142],"for":[15,24,79,124,130,152,218],"the":[16,19,34,56,60,75,80,97,112,125,131,140,144],"design":[17,76],"development":[20,81],"measurement":[22,106,155,175,207],"transformers":[23,63],"high-voltage":[25],"(HV)":[26],"systems":[27],"deeply":[28],"different":[29],"from":[30],"those":[31,122],"based":[32],"on":[33],"traditional":[35,61,119],"electromagnetic":[36,62],"principle.":[37],"Several":[38],"advantages":[39],"are":[40,92,157],"offered":[41],"by":[42],"these":[43],"new":[44],"solutions:":[45],"higher":[46],"metrological":[47],"characteristics,":[48],"cost":[49],"effectiveness,":[50],"compact":[51],"size,":[52],"lack":[54],"typical":[57],"problems":[58],"(magnetic":[64],"core":[65],"saturation,":[66],"magnetic":[67],"resonance,":[68],"bandwidth":[69],"limits,":[70],"etc.).":[71],"In":[72,138],"this":[73],"paper,":[74],"criteria":[77],"adopted":[78],"a":[83,86,115,178,186],"prototype":[84],"novel":[87],"HV":[88],"combined":[90,174],"transformer":[91,176],"presented.":[93],"Its":[94],"architecture":[95],"permits":[96],"implementation":[98],"both":[100],"voltage":[101,126,181,221],"current":[103,132,189,219],"protective":[104],"functions.":[107],"starting":[109],"point":[110],"employment":[113],"mix":[116],"well-tested":[118],"technologies":[120],"(like":[121],"used":[123],"capacitive":[127],"divider":[128],"sensor)":[133],"very":[135],"sophisticated":[136],"electronics.":[137],"particular,":[139],"employed":[145],"system":[146],"architecture,":[147],"beyond":[148],"what":[149],"conceived":[151],"obtaining":[153],"high":[154],"performances,":[156],"also":[158,212],"oriented":[159],"to":[160],"provide":[161],"advanced":[162],"ancillary":[163],"functions":[164],"such":[165],"as":[166],"autodiagnosis,":[167],"fault":[168],"tolerance,":[169],"autocalibration,":[170],"etc.":[171],"developed":[173],"features":[177],"rated":[179,187],"primary":[180,188],"145/\u221a3":[183],"kV":[184],"1000":[191],"A.":[192],"Moreover,":[193],"it":[194],"fully":[196],"compliant":[197],"with":[198],"IEC":[199,202],"60044-7":[200],"60044-8":[203],"standards,":[204],"assuring":[205],"0.1":[206],"precision":[208],"class":[209],"satisfying":[211],"5P":[213],"3P":[215],"protection":[216],"classes":[217],"sections,":[222],"respectively.":[223]},"counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2025,"cited_by_count":9},{"year":2024,"cited_by_count":1},{"year":2022,"cited_by_count":1},{"year":2021,"cited_by_count":2},{"year":2020,"cited_by_count":7},{"year":2019,"cited_by_count":2},{"year":2018,"cited_by_count":5},{"year":2017,"cited_by_count":6},{"year":2016,"cited_by_count":2},{"year":2015,"cited_by_count":3},{"year":2014,"cited_by_count":7},{"year":2013,"cited_by_count":5},{"year":2012,"cited_by_count":4}],"updated_date":"2025-11-06T03:46:38.306776","created_date":"2025-10-10T00:00:00"}