{"id":"https://openalex.org/W2123015244","doi":"https://doi.org/10.1109/tim.2008.2011091","title":"Comparison Among Coaxial Microcalorimeter Models","display_name":"Comparison Among Coaxial Microcalorimeter Models","publication_year":2009,"publication_date":"2009-01-16","ids":{"openalex":"https://openalex.org/W2123015244","doi":"https://doi.org/10.1109/tim.2008.2011091","mag":"2123015244"},"language":"en","primary_location":{"id":"doi:10.1109/tim.2008.2011091","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2008.2011091","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},"type":"article","indexed_in":["arxiv","crossref"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/2103.04835","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"L. Brunetti","orcid":null},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"L. Brunetti","raw_affiliation_strings":["Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electromagnetism Division, Istituto Nazionale di Ricerca Metrologica, Torino, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":null,"display_name":"L. Oberto","orcid":null},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"L. Oberto","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Torino, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Torino, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"middle","author":{"id":null,"display_name":"M. Sellone","orcid":null},"institutions":[{"id":"https://openalex.org/I4210136559","display_name":"Istituto Nazionale di Ricerca Metrologica","ror":"https://ror.org/03vn1bh77","country_code":"IT","type":"facility","lineage":["https://openalex.org/I4210104593","https://openalex.org/I4210136559","https://openalex.org/I4392021227"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"M. Sellone","raw_affiliation_strings":["Istituto Nazionale di Ricerca Metrologica, Torino, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Istituto Nazionale di Ricerca Metrologica, Torino, Italy","institution_ids":["https://openalex.org/I4210136559"]}]},{"author_position":"last","author":{"id":null,"display_name":"E.T. Vremera","orcid":null},"institutions":[{"id":"https://openalex.org/I4210108695","display_name":"Gheorghe Asachi Technical University of Ia\u0219i","ror":"https://ror.org/014zxnz40","country_code":"RO","type":"education","lineage":["https://openalex.org/I4210108695"]}],"countries":["RO"],"is_corresponding":false,"raw_author_name":"E.T. Vremera","raw_affiliation_strings":["Faculty of Electrical Engineering, Gheorghe Asachi Technical University of Iasi, Iasi, Romania"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Electrical Engineering, Gheorghe Asachi Technical University of Iasi, Iasi, Romania","institution_ids":["https://openalex.org/I4210108695"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":1.835,"has_fulltext":false,"cited_by_count":17,"citation_normalized_percentile":{"value":0.85911023,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":96},"biblio":{"volume":"58","issue":"4","first_page":"1141","last_page":"1145"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.48019999265670776,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.48019999265670776,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11607","display_name":"Microwave and Dielectric Measurement Techniques","score":0.3398999869823456,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12019","display_name":"Calibration and Measurement Techniques","score":0.04100000113248825,"subfield":{"id":"https://openalex.org/subfields/2202","display_name":"Aerospace Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/coaxial","display_name":"Coaxial","score":0.8258000016212463},{"id":"https://openalex.org/keywords/calibration","display_name":"Calibration","score":0.7511000037193298},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"Measurement uncertainty","score":0.5020999908447266},{"id":"https://openalex.org/keywords/power","display_name":"Power (physics)","score":0.4952999949455261},{"id":"https://openalex.org/keywords/thermoelectric-effect","display_name":"Thermoelectric effect","score":0.4683000147342682},{"id":"https://openalex.org/keywords/temperature-measurement","display_name":"Temperature measurement","score":0.414900004863739},{"id":"https://openalex.org/keywords/metrology","display_name":"Metrology","score":0.39239999651908875}],"concepts":[{"id":"https://openalex.org/C51221625","wikidata":"https://www.wikidata.org/wiki/Q1751466","display_name":"Coaxial","level":2,"score":0.8258000016212463},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.7511000037193298},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.5020999908447266},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4952999949455261},{"id":"https://openalex.org/C63024428","wikidata":"https://www.wikidata.org/wiki/Q552456","display_name":"Thermoelectric effect","level":2,"score":0.4683000147342682},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.4562999904155731},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4339999854564667},{"id":"https://openalex.org/C72293138","wikidata":"https://www.wikidata.org/wiki/Q909741","display_name":"Temperature measurement","level":2,"score":0.414900004863739},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.39239999651908875},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3619000017642975},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.32260000705718994},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.2985000014305115},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.2955999970436096},{"id":"https://openalex.org/C128458982","wikidata":"https://www.wikidata.org/wiki/Q18891486","display_name":"Thermoelectric cooling","level":3,"score":0.28949999809265137},{"id":"https://openalex.org/C3018824978","wikidata":"https://www.wikidata.org/wiki/Q2894891","display_name":"Error analysis","level":2,"score":0.28540000319480896},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2761000096797943},{"id":"https://openalex.org/C67186554","wikidata":"https://www.wikidata.org/wiki/Q17103352","display_name":"Maximum power transfer theorem","level":3,"score":0.2630999982357025},{"id":"https://openalex.org/C19619285","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Observational error","level":2,"score":0.259799987077713}],"mesh":[],"locations_count":3,"locations":[{"id":"doi:10.1109/tim.2008.2011091","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tim.2008.2011091","pdf_url":null,"source":{"id":"https://openalex.org/S10892749","display_name":"IEEE Transactions on Instrumentation and Measurement","issn_l":"0018-9456","issn":["0018-9456","1557-9662"],"is_oa":false,"is_in_doaj":false,"is_core":true,"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Instrumentation and Measurement","raw_type":"journal-article"},{"id":"pmh:oai:arXiv.org:2103.04835","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2103.04835","pdf_url":"https://arxiv.org/pdf/2103.04835","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},{"id":"pmh:oai:iris.inrim.it:11696/31005","is_oa":false,"landing_page_url":"http://hdl.handle.net/11696/31005","pdf_url":null,"source":{"id":"https://openalex.org/S4306400708","display_name":"CINECA IRIS Institutional Research Information System (IRIS Istituto Nazionale di Ricerca Metrologica)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I27837315","host_organization_name":"University of Michigan","host_organization_lineage":["https://openalex.org/I27837315"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":{"id":"pmh:oai:arXiv.org:2103.04835","is_oa":true,"landing_page_url":"http://arxiv.org/abs/2103.04835","pdf_url":"https://arxiv.org/pdf/2103.04835","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1522319254","https://openalex.org/W1530777352","https://openalex.org/W1988095506","https://openalex.org/W1999674132","https://openalex.org/W2009037785","https://openalex.org/W2066834029","https://openalex.org/W2099415444","https://openalex.org/W2136959914","https://openalex.org/W2153632641","https://openalex.org/W2167519225"],"related_works":[],"abstract_inverted_index":{"Thermoelectric":[0],"power":[1,5,31],"sensors":[2],"used":[3],"as":[4],"transfer":[6],"standards":[7],"are":[8,86],"promising":[9],"devices":[10],"for":[11,67],"further":[12],"enhancements":[13],"of":[14,63,83],"the":[15,19,34,42,64,68,84],"microcalorimetric":[16],"technique":[17],"in":[18,61],"high-frequency":[20],"field.":[21],"A":[22],"coaxial":[23,70],"microcalorimeter":[24],"has":[25],"been":[26,47],"studied,":[27],"based":[28],"on":[29],"thermoelectric":[30],"sensors,":[32],"at":[33],"Istituto":[35],"Nazionale":[36],"di":[37],"Ricerca":[38],"Metrologica":[39],"(INRIM).":[40],"In":[41],"literature,":[43],"several":[44],"models":[45,60,85],"have":[46],"proposed,":[48],"considering":[49],"different":[50],"calibration":[51],"processes":[52],"and":[53,76,81],"error":[54],"sources.":[55],"Hereby,":[56],"we":[57],"analyze":[58],"these":[59],"terms":[62],"total":[65],"uncertainty":[66],"3.5-mm":[69],"line":[71],"case":[72],"between":[73],"10":[74],"MHz":[75],"26.5":[77],"GHz.":[78],"The":[79],"advantages":[80],"disadvantages":[82],"highlighted.":[87]},"counts_by_year":[{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":2},{"year":2021,"cited_by_count":1},{"year":2019,"cited_by_count":1},{"year":2018,"cited_by_count":1},{"year":2016,"cited_by_count":1},{"year":2015,"cited_by_count":1},{"year":2014,"cited_by_count":1},{"year":2013,"cited_by_count":1},{"year":2012,"cited_by_count":1}],"updated_date":"2026-08-26T07:47:46.906454","created_date":"2016-06-24T00:00:00"}
